Appendix: Supported alarms

Equipment alarms

Alarm ID: 1001
Alarm name: Fan Tray Fault
Description: This alarm is raised when the associated fan-tray is in down/empty/failed/degraded/low-power operational state. The system may have cooling issues.
Severity: Major
Probable cause: Equipment malfunction
Remedial action: The failed fan unit should be replaced.
Alarm ID: 1003
Alarm name: Power Supply Fault
Description: The alarm is raised when the associated power supply is not operationally Up. The specified power supply can no longer supply power to the system.
Severity: Critical
Probable cause: Power problem
Remedial action: Check the status of the power supply.
Alarm ID: 1004
Alarm name: Chassis Fault
Description: The alarm is raised when chassis is operationally down.
Severity: Critical
Probable cause: Equipment malfunction
Remedial action: Chassis Down
Alarm ID: 1005
Alarm name: CPM Fault
Description: This alarm is generated when the control module is in an operationally down/empty/failed/degraded/low-power state.
Severity: Critical
Probable cause: Equipment malfunction
Remedial action: Remove the card and reset it. If this does not clear the alarm then please contact your Nokia support representative for assistance.
Alarm ID: 1006
Alarm name: SFM Fault
Description: The alarm is raised when the associated SFM module is in operationally down/empty/failed/degraded/low-power state. Traffic could be impacted.
Severity: Critical
Probable cause: Equipment malfunction
Remedial action: The active CPM is at risk of failing to initialize after node reboot because it cannot access the SFM. Contact Nokia customer support.
Alarm ID: 1007
Alarm name: Line Card Fault
Description: The alarm is raised when the specified line card is operationally down/empty/failed/degraded/low-power state. Traffic is no longer being transmitted from this line card.
Severity: Major
Probable cause: Equipment malfunction
Remedial action: Ensure line card is operationally up. Linecard may need to be replaced.

Communication alarms

Alarm ID: 4001
Alarm name: LLDP Adjacency Down
Description: The alarm is raised when the Operational State of an LLDP adjacency is down. This is because the operational state of local interface is in a down state.
Severity: Major
Probable cause: DTE DCE Interface Error
Remedial action: The operational state of the interface must be up in order for the selected adjacency to be up.
Alarm ID: 4002
Alarm name: Interface Down
Description: The alarm is raised when the operational state of interface is down.
Severity: Critical
Probable cause: DTE DCE Interface Error
Remedial action: The condition exists because the physical interface is down either because it is administratively disabled, faulty or a cabling fault has occurred. Ensure that the interface is administratively up.

Check for a poor cable connection to the port or for a faulty cable/fiber. If neither appears to be the problem run diagnostics on the port to determine if it is faulty.

Alarm ID: 4003
Alarm name: Subinterface Down
Description: The alarm is raised when the operational state of subinterface is down.
Severity: Critical
Probable cause: DTE DCE Interface Error
Remedial action: The condition exists because the subinterface is down either because it is administratively disabled, faulty or a cabling fault has occurred. Ensure that the subinterface is administratively up.

Check for a poor cable connection to the port or for a faulty cable/fiber. If neither appears to be the problem run diagnostics on the port to determine if it is faulty.

Operational alarms

Alarm ID: 5001
Alarm name: GNMI Connection Fault
Description: GNMI connection to the network element has been lost.
Severity: Major
Probable cause: DTE DCE Interface Error
Remedial action: Check network connectivity to restore GNMI connection.