Procedure 12-8.4: Upgrade high-speed UPSR connections at node equipped with compatible OC-48 OLIU in Main slot M2

Important!

This is not a stand-alone procedure. Perform this procedure only as directed by another procedure.

Steps

Important!

Compatible OC-48 OLIU circuit packs include LNW27 (Series 1:6 and later), LNW29 (Series 1:6 and later), LNW32, LNW76 (Series 1:6 and later), LNW82, LNW202, and LNW221–259 (Series 1:6 and later) OC-48 OLIU circuit packs.

When optical fibers are disconnected during this procedure, inc. LOS, section DCC channel failed, and neighbor SYSCTL CP unavailable alarms are reported. The holdover mode active condition may also be reported depending on the provisioned system timing mode.

Complete the following steps to upgrade the in-service high-speed UPSR connections at a node equipped with a compatible OC-48 OLIU circuit pack in Main slot M2.

 
1

Are you upgrading a Very Large Fabric (VLF) multi-port, multi-rate LNW82 OLIU to Very Large Fabric (VLF) LNW59 OC-192 OLIU (one port)?

If...

Then...

Yes

Upgrading an LNW82 circuit pack to an LNW59 circuit pack is only allowed Port 1 of the LNW82 circuit packs is provisioned as OC-48 and and all other OC-n ports are provisioned as STNA.

Continue with Step 2.

No

Proceed to Step 4.


2

Determine the port provisioning of the LNW82, port 1 at the starting node using Reports → Equipment Lists → Ports.Click CP main-1 and then click Select. Observe the Port Type and Application of Main-1-1 and the other ports. Click Close.


3

What is the Port Type and Application of Main-1-1?

If...

Then...

OC48, upsr and all other ports are STNA

Continue with Step 4.

OC48 upsr and one or more of the remaining ports has a Port Type of OC3, OC12, or OC48

You must roll all traffic from the other ports to any OC-3/12/48 ports in the Function slots in the same shelf.

Proceed to Procedure 10-10: Bridge and roll cross-connections to roll the traffic.

For each port that you rolled traffic from, change Signal Type to STNA.

  1. Select Configuration → Equipment from the System View main menu.

  2. Expand the LNW82 circuit pack details and highlight the OCN port and click Select.

  3. For Signal Type, select STNA from the drop down menu and click Apply. Refer to Signal Type: STNA if you have issues changing the Signal Type.

  4. Repeat this procedure, Procedure 12-8.4: Upgrade high-speed UPSR connections at node equipped with compatible OC-48 OLIU in Main slot M2.

OC48, blsr and all other ports are STNA

Proceed to Procedure 12-11: Upgrade OC-48 BLSR to OC-192 BLSR.

OC48, blsr and one or more of the remaining ports has a Port Type of OC3, OC12, or OC48

You must roll all traffic from the other ports to any OC-3/12/48 ports in the Function slots in the same shelf.

Proceed to Procedure 10-10: Bridge and roll cross-connections to roll the traffic.

For each port that you rolled traffic from, change Signal Type to STNA.

  1. Select Configuration → Equipment from the System View main menu.

  2. Expand the LNW82 circuit pack details and highlight the OCN port and click Select.

  3. For Signal Type, select STNA from the drop down menu and click Apply. Refer to Signal Type: STNA if you have issues changing the Signal Type.

  4. Proceed to Procedure 12-11: Upgrade OC-48 BLSR to OC-192 BLSR.

OC3 or OC12 (Application does not matter)

Upgrade of Port 1 to an LNW59 is not supported.

End of procedure.


4

If required, verify the active/standby status of the OC-48 OLIU circuit pack in Main slot M1 and perform manual switches to switch traffic away from an active circuit pack.

Reference:

Procedure 12-8.5: Verify active/standby status of circuit pack to be replaced


5

Important!

The Ring Upgrade Mode is required for cross-connections and provisioning data to be mapped to the replacement circuit pack.

At the WaveStar® CIT System View, select Configuration → Ring Upgrade Mode.

Result:

A dialog box appears asking you to confirm changing the NE Mode to Ring Upgrade Mode. Click Yes.

The ABN LED is lighted on the SYSCTL circuit pack faceplate and the WaveStar® CIT Alarm List shows the Ring Upgrade Mode as Not Alarmed.

For more information about the Ring Upgrade Mode, refer to Ring Upgrade Mode.


6

Important!

If the circuit pack is active for timing and/or transmission, opening the latch causes timing and/or transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch.

Open the lower faceplate latch on the OC-48 OLIU circuit pack in Main slot M1. Disconnect the optical fibers from the OC-48 OLIU circuit pack in Main slot M1. Then replace the OC-48 OLIU circuit pack in Main slot M1 with the replacement OC-192 OLIU circuit pack.

Result:

A transmission hit may occur after the OC-192 OLIU circuit pack is inserted. The transmission hit is a result of an internal system timing adjustment to accommodate different line rates in the two Main slots.

The replacement OC-192 OLIU circuit pack in Main slot M1 is tested and autoprovisioned.

The system reports an unexpected circuit pack type condition and an inc. OC48 LOS alarm for Main slot M1.

If the provisioned system timing mode is External, the system may also report an inc. DS1 sync. ref. OOL alarm.

Reference:

Procedure 4-2: Install OLIU circuit packs in Main slots


7

At both ends of the optical span to be upgraded, perform the following to connect the replacement OC-192 OLIU circuit pack in Main slot M1 and the required OC-192 circuit pack/port at the opposite end of the upgraded OC-192 optical span:

  1. Clean and connect the transmit optical fibers.

  2. Measure the optical receive power of the receive fibers using an optical power meter. Select the appropriate LBO to attenuate the receive signal to the middle of the allowable optical receive power range. (Refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) Applications and Planning Guide, 365-372-300 for the SONET optical specifications of the OC-192 circuit packs.)

  3. Clean and connect the receive fibers.

Result:

The inc. OC48 LOS alarm clears. Transmission is now supported on the upgraded optical span.

Reference:

Procedure 14-4: Perform connection and verification of optical facility


8

Important!

The UPD/INIT button does not work during this upgrade.

At the System View select Configuration → Update System → Upgrade. Select main-1 (default) as the Directed Slot Choice and click OK.

Result:

A dialog box appears asking you to confirm executing this command. Click Yes.

The unexpected circuit pack type condition for Main slot M1 clears, and the system reports an unexpected circuit pack type condition for Main slot M2.


9

If required, verify the active/standby status of the OC-48 OLIU circuit pack in Main slot M2 and perform manual switches to switch traffic away from an active circuit pack.

Reference:

Procedure 12-8.5: Verify active/standby status of circuit pack to be replaced


10
DANGER 

NOTICE

Equipment damage hazard

If an OC-192 OLIU circuit pack is connected to an OC-48 OLIU circuit pack equipment damage may occur.

Do not reconnect the optical fibers until instructed to do so. The optical fibers are reconnected after the OC-48 OLIU circuit pack is upgraded at each end of the optical span.

Important!

If the circuit pack is active for timing and/or transmission, opening the latch causes timing and/or transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch.

Open the lower faceplate latch on the OC-48 OLIU circuit pack in Main slot M2. Disconnect the optical fibers from the OC-48 OLIU circuit pack in Main slot M2. Then replace the OC-48 OLIU circuit pack in Main slot M2 with the replacement OC-192 OLIU circuit pack.

Result:

A transmission hit will occur after the OC-48 OLIU circuit pack is removed. The transmission hit is the result of an internal system timing adjustment to accommodate different line rates in the two Main slots.

The replacement OC-192 OLIU circuit pack in Main slot M2 is tested and autoprovisioned.

The unexpected circuit pack type condition for Main slot M2 clears, and the system reports an inc. OC192 LOS alarm for Main slot M2. Alarms may also be reported at other nodes in the ring.

Reference:

Procedure 4-2: Install OLIU circuit packs in Main slots

The following figure shows the state of the current node and the adjacent optical spans.

View the figure

STOP! To complete the upgrade, return to the procedure that directed you to perform this procedure.


End of steps

Signal Type: STNA

Select STNA to change the rate of an optical line on a multirate pack to unprovisioned.

STNA is the initial value for all ports when the circuit pack is accepted into a function/growth group with no expected circuit pack type. If the companion circuit pack is an accepted circuit pack with the same circuit pack type, the value is set to the Signal Type of the companion for protected appications. For 0x1 applications, the value is set to STNA

When provisioned STNA, synchronization messaging (syncmsg) is DISABLED, DCC is DISABLED (and is not retrievable), and there is no line primary state (pst). No DBCHG messages are issued for those parameters which changed. No line parameters other than may be provisioned or retrieved. When the Signal Type parameter is changed from STNA to any other value, the port application is set to 0x1. All other port parameters are set to their default values.

STNA value is not allowed if

Note:

If Signal Type is OC-48 on ports 1, 3, 5, or 7, then the STNA ports 2, 4, 6, or 8 are NOT provisionable as OC-48 uses up bandwidth for both the odd and the next higher even port as well. For example, if port 3 is configured for OC-48, port 4 is STNA and is not configurable.