Procedure 4-2: Install OLIU circuit packs in Main slots

- Overview

Use this procedure to install OLIU circuit packs in the Main slots.

Important!

The OLIU circuit packs in the Main slots must both have the same optical line rate and VT cross-connect size. If the circuit packs in the Main slots have different optical line rates or VT cross-connect sizes, the system reports an unexpected CP type alarm and service may be impacted.

If installing LNW80 Switch circuit packs in the Main slots, refer to Procedure 4-16: Install LNW80 switch pack.

- Privilege level

You must log in as a Privileged, General, Maintenance, or Reports Only user to complete this procedure.

Required equipment

In addition to the equipment listed in Required equipment, the following equipment is also required:

  • Erasable marker or pencil

  • Optical loopback cables, LBOs, and optical fiber cleaning tools (if loopbacks are performed)

  • A deeper shelf cover (comcode 849068358) is required for shelves equipped with LNW82 OC3/OC12/OC48 and LNW504 OC-48/OC-192 circuit packs. This shelf cover provides more space to prevent fibers from touching the front cover when the cover is closed.

Use only Alcatel-Lucent Approved Class 1 SFP/XFP transceivers. Refer to the list of pluggable transmission modules in Procedure 4-15: Install pluggable transmission modules.

Refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) Installation Manual, 365-372-304, as required, when removing and/or installing pluggable transmission modules.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

  3. Obtain the work instructions for this procedure. It is especially important to know desired wavelengths and enhanced mode requirements (12 STS-1s) when applicable.

  4. Ensure that correct OLIU circuit packs are available for installation.

    The OLIU circuit packs in Main slots must have the same size VT cross-connect fabric. For example, the LNW27 and LNW29 OC-48 OLIU circuit packs have full (up to 48 STS-1s) VT mapping; therefore, they can be used together in the Main slots. If the circuit packs in the Main slots have different VT cross-connect fabric sizes, the system reports an unexpected CP type alarm.

    The following is a list of Main OLIU circuit packs grouped by switch fabric:
    • OC-12 OLIUs with 12 STS-1 switch fabric: LNW48 LNW50 LNW54 LNW203

    • OC-48 OLIUs with 12 STS-1 switch fabric: LNW26B (jumper set to enhanced) LNW28 (jumper set to enhanced) LNW77 (jumper set to enhanced) LNW121B–LNW159B (jumper set to enhanced)

      LNW26B, LNW28, LNW77, LNW121B–LNW159B OC-48 OLIUs with 6 STS-1 switch fabric (jumper set to normal) are not supported in Release 6.0.

      The LNW26B, LNW28, LNW77, and LNW121B–159B OLIU circuit packs are DA’ed and are no longer available.

    • OC-48 OLIUs with 48 STS-1 switch fabric: LNW27 LNW29 LNW32 LNW76 LNW202 LNW221–LNW259.

      LNW221–LNW259 are DA'd and are no longer available

    • OC-192 OLIUs with 48 STS-1 switch fabric: LNW56 LNW57 LNW58 LNW60 LNW502 LNW523 LNW527 LNW554 LNW555

      The LNW523 LNW527 LNW554 LNW555 are DA'd and are no longer available

    • Very Large Fabric multiport OC-192 OLIUs with 576 STS-1 switch fabric: LNW59

    • Very Large Fabric multiport multirate OC3/OC12/OC48 OLIUs with 192 STS-1 switch fabric: LNW82

    • Very Large Fabric multipor, multirate OC48/OC192 OLIUs with 576 STS-1 switch fabric: LNW504

Important!

The Very Large Fabric LNW59, LNW82, and LNW504 circuit packs are only compatible with the Alcatel-Lucent 1665 DMX High Capacity Shelf (DMX-HC-20A, DMX-HC-30A, or DMX-HC-30A-CE Shelf Type). The Standard Alcatel-Lucent 1665 DMX Shelf does not support LNW59, LNW82, and LNW504 circuit packs. If LNW59, LNW82, and LNW504 circuit packs are installed in the Standard Alcatel-Lucent 1665 DMX Shelf, the system will not recognize the circuit pack as an allowable type.

To determine the shelf type, select View → Equipment, highlight Shelf, and click Select to obtain the shelf details.

Steps

Complete the following steps to install OLIU circuit packs in the Main slots.

 
1

Are you installing an LNW121B–159B or LNW221–259 OLIU circuit pack?

If...

Then...

Yes

Continue with Step 2.

No

Proceed to Step 5.

Note:

The LNW121B–159B and LNW221–LNW259 OLIU circuit packs are DA’ed and are no longer available.


2

From your work orders, determine the wavelength that you wish to set on the LNW121B–LNW159B or LNW221–LNW259 circuit pack. Use the Channel Select Option Label on the faceplate of the circuit pack to determine the correct channel.

For example, the Channel Select Option Label on the faceplate of the LNW137B circuit pack in Figure 4-1, Channel select option label on LNW137B shows that CH X must selected if CH37 (193.700 THz; 1547.715 nm) is desired.

Figure 4-1: Channel select option label on LNW137B
Channel select option label on LNW137B
3

If you are installing an:

  • LNW121B–159B, refer to Figure 4-2, Jumper settings for LNW121B–159B
    • Set the channel selection jumper on your circuit pack to either CH X or CH Y for your desired wavelength/channel.

    • Set the enhanced/normal jumper on your circuit pack to Enhanced (switch fabric can cross-connect VT across any 12 STS-1s). Normal (switch fabric can cross-connect VT across any 6 STS-1s) is not supported in Release 6.0.

    LNW221–259, refer to Figure 4-3, Jumper settings for LNW221–259
    • Set the channel selection jumper on your circuit pack to either CH X or CH Y for your desired wavelength/channel.

Figure 4-2: Jumper settings for LNW121B–159B
Jumper settings for LNW121B–159B
Figure 4-3: Jumper settings for LNW221–259
Jumper settings for LNW221–259
4

Using an erasable marker or pencil, check the appropriate box on the Channel Select Option Label, refer to Figure 4-1, Channel select option label on LNW137B, that corresponds to your jumper setting.

Important!

This label is the only means available to identify the wavelength selected when the pack is fully seated and/or in-service.


5

Are you installing an LNW26B, LNW28, LNW77, LNW121B–159B OLIU circuit pack?

If...

Then...

Yes

Continue with Step 6.

No

Proceed to Step 7.


6

Set the enhanced/normal jumper on your circuit pack to Enhanced (switch fabric can cross-connect VT across any 12 STS-1s). Normal (switch fabric can cross-connect VT across any 6 STS-1s) is not supported in Release 6.0. Refer to Figure 4-4, Jumper settings for enhanced mode.

Figure 4-4: Jumper settings for enhanced mode
Jumper settings for enhanced mode
7

Ensure all optical fiber connectors and couplings are properly cleaned.

Important!

Signal performances may be degraded if the connections and couplings are not cleaned properly.

Reference:

Procedure 14-3: Clean optical fibers, dual LC adapters and LC lightguide buildouts (LBOs)


8

Important!

Pluggable transmission modules are shipped with a dust cover installed into the optical ports to maintain cleanliness during storage and/or transportation. It is recommended that the dust cover be kept in place to maintain cleanliness until the optical fiber is connected. With proper care and handling, cleaning the pluggable transmission modules should not be necessary.

If required, clean the pluggable transmission module(s).

Reference:

Procedure 14-29: Clean optical pluggable transmission module


9

Important!

A deeper shelf cover (comcode 849068358) is required for shelves equipped with LNW82 OC3/OC12/OC48 and LNW504 OC-48/OC-192 circuit packs. This shelf cover provides more space to prevent fibers from touching the front cover when the cover is closed.

If required, verify that the shelf is equipped with the deeper shelf cover and carefully remove any caution tags that are attached to the LNW82 or LNW504 circuit pack.


10

Seat the first OLIU circuit pack in Main slot M1 by applying steady pressure to both faceplate latches.

Result:

For non-VLF OLIU circuit packs, the FAULT LED lights for approximately 20 seconds then goes off, indicating successful installation.

For VLF OLIU circuit packs, the FAULT LED lights for approximately 10 minutes then goes off, indicating successful installation.

Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation.

If response is not correct, replace the OLIU circuit pack. Refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) Alarm Messages and Trouble Clearing Guide, 365-372-302.


11

Seat the second OLIU circuit pack in Main slot M2 by applying steady pressure to both faceplate latches.

Result:

For non-VLF OLIU circuit packs, the FAULT LED lights for approximately 20 seconds then goes off, indicating successful installation.

For VLF OLIU circuit packs, the FAULT LED lights for approximately 10 minutes then goes off, indicating successful installation.

Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation.

If response is not correct, replace the OLIU circuit pack. Refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) Alarm Messages and Trouble Clearing Guide, 365-372-302.


12

Important!

The LNW59 OC-192 OLIU circuit pack may be equipped with up to two pluggable transmission modules. However, pluggable transmission modules are not required when the LNW59 OC-192 OLIU circuit pack is used in headless, optics-free, switch applications.

The LNW82 OLIU circuit pack may be equipped with a mix of up to eight OC-3/12/48 pluggable transmission modules. However, pluggable transmission modules are not required when the LNW82 OLIU circuit pack is used in headless, optics-free, switch applications.

The LNW504 OLIU circuit pack may be equipped with up to four OC-192 pluggable transmission modules or up to three OC–192 pluggable transmission modules and up to four OC-48 pluggable transmission modules. However, pluggable transmission modules are not required when the LNW504 OLIU circuit pack is used in headless, optics-free, switch applications.

The LNW202 OC-48, LNW203 OC-12, and LNW502 OC-192 OLIU circuit packs may be equipped with one pluggable transmission module.

If required, install pluggable transmission modules.

Reference:

Procedure 4-15: Install pluggable transmission modules


13

If optical port testing is...

Then...

required and has not already been performed,

Determine the optical port to be tested and continue with Step 14.

not required or has already been performed,

Proceed to Step 20.


14

Important!

If the port Signal Type parameter is STNA (Signal Type Not Available) for a port on an LNW82 or LNW504 multirate OLIU circuit pack, then the port is not usable and cannot be tested.

Select Configuration → DCC Terminations to access the required usable optical port on the installed OLIU circuit pack and provision OSI over DCC as disabled to prevent DCC-related alarms. Click Apply and Close.


15

Loop back the required optical port on the installed OLIU circuit pack to test port functionality.

Reference:

Procedure 14-6: Connect OLIU optical loopbacks


16

Remove the lightguide jumper used to loop back the port and the LBO, if required.

Result:

The OLIU FAULT LED and the port LED associated with the pluggable transmission module starts flashing. The MN and NE LEDs are lighted on the SYSCTL circuit pack.


17

From the System View window, click the Alarm List button to obtain the NE Alarm List and verify that the alarm is associated with the port being tested.


18

Important!

It is recommended that the dust cover be installed into the optical ports on the pluggable transmission module to maintain cleanliness until the optical fiber is connected.

If required, reinstall the dust cover into the optical ports on the pluggable transmission module to maintain cleanliness.


19

Select Configuration → Update System → Update All to clear the incoming signal alarms.

Result:

The OLIU FAULT LED and the port LED associated with the pluggable transmission module stops flashing. All alarms are cleared.

If required, repeat Step 14 through Step 19 to test all usable optical ports on the OLIU circuit packs just installed.


20

From the System View window, click the Alarm List button to obtain the NE Alarm List. Verify that no alarms, protection switches, protection switch lockouts, and loopbacks are present for the ports on the OLIU circuit packs just installed.

Result:

No alarms should be present for the OLIU circuit packs just installed.


21

If required at this time, provision the circuit pack and/or port parameters.

Reference:

Procedure 4-4: Provision OLIU circuit packs/ports for service


End of steps

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.