Use this procedure to install the following TMUX circuit packs:
If installing LNW20 48TMUXDS3EC1 circuit packs, the following large fabric or very large fabric OLIU circuit packs are required in the Main slots to support portless operation.
If the Main slots are equipped with Very Large Fabric LNW59, LNW82, or LNW504 OLIU circuit packs, portless operation is supported on all ports.
If the Main slots are equipped with large fabric (non-VLF) circuit packs, portless operation is supported on the odd ports only. The even ports are unavailable.
If the Main slots are not equipped with large fabric or very large fabric OLIU circuit packs, attempts to provision portless operation will be denied.
The circuit packs in a Function group must be the same circuit pack type. For example, both circuit packs in a Function group must be LNW18 TMUX circuit packs. If the circuit packs in a Function group are different circuit pack types, the system reports an unexpected CP type alarm and service may be impacted.
You must log in as a Privileged, General, Maintenance, or Reports Only user to complete this procedure.
Prior to performing this procedure:
Refer to Required equipment and Before you begin in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Ensure that the TMUX circuit packs are available for installation.
Use the work instructions and select View → Equipment to access the circuit pack details and determine if the Main slots are equipped with large fabric or very large fabric circuit packs.
Complete the following steps to install TMUX circuit packs.
1 |
Determine the Function group slots (A, B, C, or D) being equipped with TMUX circuit packs. Important! If the Main slots are equipped with large fabric or very large fabric circuit packs, the LNW20 48TMUXDS3EC1 circuit packs can also be used in the Growth slots for portless-only operation. Reference: | ||||||
2 |
Open both faceplate latches and seat the circuit pack in the required slot by applying steady pressure to both faceplate latches. Result: For circuit packs with the current firmware installed, the FAULT LED lights for approximately 30 seconds and then the ACTIVE LED lights to indicate success. For older circuit packs, the following sequence occurs:
Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation. | ||||||
3 |
Is a second (protection) TMUX circuit pack required in the companion slot?
| ||||||
4 |
Open both faceplate latches and seat the second (protection) TMUX circuit pack in the companion slot by applying steady pressure to both faceplate latches. Result: For circuit packs with the current firmware installed, the FAULT LED lights for approximately 30 seconds to indicate success. For older circuit packs, the following sequence occurs:
Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation. | ||||||
5 |
From the System View window, click the Alarm List button to verify that no alarms, loopbacks, protection switch lockouts, or protection switches are present for the ports on the circuit packs just installed. Result: The NE Alarm List appears. No alarms should be present for the circuit pack just installed. | ||||||
6 |
If required at this time, provision the circuit pack and/or port parameters. Reference: Procedure 4-11: Provision TMUX circuit packs/ports for service End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |