Important!
This is not a stand-alone procedure. Perform this procedure only as directed by another procedure.
Complete the following steps to upgrade a DWDM-compatible OC-192 span to a DWDM OTS span.
1 |
Important! An OMD circuit pack with an available OCH port is required in a Function/Growth slot at each node that terminates the OC-n span to be upgraded. If required, install an OMD circuit pack in a Function/Growth slot. Reference: Procedure 4-25: Install DWDM optical multiplexer/demultiplexer circuit packs | ||
2 |
If required, verify the active/standby status of the required OC-192 port and perform manual switches to switch traffic away from an active OC-192 port. Reference: Procedure 12-27.3: Verify active/standby status of OC-n port | ||
3 |
Removing the wrong fiber connections will result in a service interruption. Using the work instructions, ensure that you remove only the fiber connections for the optical span being upgraded. Important! If the OC-192 port is active for transmission, disconnecting the optical fibers causes transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch. Disconnect the required OC-192 span fibers from the OLIU circuit pack/pluggable transmission module/port. Result: Transmission hits (less than 60 ms) may occur if traffic exists on the OC-192 port. If through traffic exists (UPSRs and BLSRs only), transmission hits (less than 60 ms) may occur at the nodes where the traffic is added/dropped. The system reports an inc. OCN LOS alarm for the OC-192 port when the OC-192 span fibers are disconnected. For BLSR protection groups, the system also reports a Line Automatic Switch condition for the OC-192 port. Alarms may also be reported at other nodes in the network. | ||
4 |
At the node at the opposite end of OC-192 span to be upgraded, repeat Step 1 through Step 3. Then continue with the next step. | ||
5 |
If required, establish a DWDM point-to-point network using the span fibers to connect the OTS ports of the OMD circuit packs. Reference: Procedure 9-12: Establish DWDM network | ||
6 |
Important! The provisioned Expected Frequency of the OC-192 DWDM pluggable transmission module/port must match the OCH port frequency. If the provisioned Expected Frequency of the OC-192 DWDM pluggable transmission module/port and the OCH port frequency are different, attempts to provision an OCH cross-connection will be denied. At the terminating nodes, install/provision the required OC-192 DWDM pluggable transmission module/port, and connect the OC-192 port to the required OCH port of the OMD circuit pack to add the OC-192 signal to the DWDM OTS span. Result: The inc. OCN LOS alarms clear. Transmission is now supported on the upgraded optical span. Reference: Procedure 10-15: Add optical channel (OCH) to DWDM network STOP! To complete the upgrade, return to the procedure that directed you to perform this procedure. End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |