Procedure 4-1: Install SYSCTL (LNW2) in new Alcatel-Lucent 1665 DMXtend shelf

- Overview

Use this procedure to install a factory-fresh SYSCTL (LNW2) in a new Alcatel-Lucent 1665 DMXtend shelf (no circuit packs installed).

- Privilege level

You must log in as a Privileged user to complete this procedure.

Required equipment

In addition to Required equipment listed in this chapter, a factory-fresh LNW2, system controller (SYSCTL), with two non-volatile memory (NVM) cards installed is also required.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

  3. Obtain the work instructions for this procedure.

Steps

Complete the following steps to install the LNW2 SYSCTL in a new shelf without other circuit packs installed.

 
1

Important!

For software installation, both NVMs must be present in the LNW2 SYSCTL.

After the LNW2 is installed, if one or both NVMs are missing, NVM removed alarm(s) are issued and:

  • If one NVM socket is empty or an NVM is failed, the IND displays an alternating N and O and x (x=1 or 2, indicating the offending NVM socket).

  • If both NVM sockets are empty, the IND displays an alternating E and 0 and 1.

Refer to Step 2 for the complete listing of codes.

Insert the LNW2 (SYSCTL) circuit pack into the slot labeled CTL in the center of the shelf using a steady pressure on both faceplate latches. Allow a few minutes for the pack to complete initialization.

Result:

The LNW2 SYSCTL exhibits the following visible cycles during initialization:

  1. The FAULT LED lights and remains lighted for approximately 90 seconds. After approximately 10 seconds, a flashing b appears in the IND display on the SYSCTL, indicating that a boot is in progress. The b continues flashing for approximately 75 seconds and then IND display is blank.

  2. The FAULT LED remains lighted for approximately another 20 seconds and then extinguishes.

  3. The ACTIVE LED lights and remains lighted and the CR LED flashes 10 times. While the CR LED is flashing, the MJ, ABN, and NE LEDs light and remain lighted.

  4. Continue with Step 2.


2

Observe the IND display on the LNW2 SYSCTL; the display indicates the state of the SYSCTL.

If...

Then...

Blank

Software is installed on the SYSCTL. Proceed to Procedure 14-14: Retrieve software generic release and database information.

alternating M and P and 9 and “.” (“.” is a red, four-segment square [2 x 2] representing a period) and 1

9.1 Maintenance Mode. Proceed to Procedure 2-1: Install software generic (initial) via FTAM or Procedure 2-2: Install software generic (initial) via FTP.

alternating M and P and 9 and “.” (“.” is a red, four-segment square [2 x 2] representing a period) and 0

9.0 Maintenance Mode. Proceed to Procedure 2-1: Install software generic (initial) via FTAM or Procedure 2-2: Install software generic (initial) via FTP.

alternating M and P and 8 and “.” (“.” is a red, four-segment square [2 x 2] representing a period) and 0

8.0 Maintenance Mode. Proceed to Procedure 2-1: Install software generic (initial) via FTAM or Procedure 2-2: Install software generic (initial) via FTP.

alternating M and P and 5 and “.” (“.” is a red, four-segment square [2 x 2] representing a period) and 1

5.1 Maintenance Mode. Proceed to Procedure 2-1: Install software generic (initial) via FTAM or Procedure 2-2: Install software generic (initial) via FTP.

alternating M and P and 5 and “.” (“.” is a red, four-segment square [2 x 2] representing a period) and 0

5.0 Maintenance Mode. Proceed to Procedure 2-1: Install software generic (initial) via FTAM or Procedure 2-2: Install software generic (initial) via FTP.

alternating M and P and 4 and “.” (“.” is a red, four-segment square [2 x 2] representing a period) and 0

4.0 Maintenance Mode. Proceed to Procedure 2-1: Install software generic (initial) via FTAM or Procedure 2-2: Install software generic (initial) via FTP.

alternating E and 0 and 0

LNW2 SYSCTL must be replaced.

Find another LNW2 SYSCTL equipped with two factory-installed NVMs and repeat this procedure.

alternating E and 0 and 1

No NVMs are detected on the LNW2 SYSCTL.

Install two Alcatel-Lucent supplied NVMs in the LNW2 or find another LNW2 SYSCTL equipped with two factory-installed NVMs and repeat this procedure.

alternating E and 0 and 2

NVMs are present but not readable. Check to make sure they are properly seated and repeat this procedure.

alternating E and 0 and 3

Not Supported.

Find another LNW2 SYSCTL equipped with two factory-installed NVMs and repeat this procedure.

alternating E and 1 and 0

LNW2 SYSCTL will not boot.

No compatible generic on the NVMs in the LNW2 SYSCTL.

Find another LNW2 SYSCTL equipped with two factory-installed NVMs and repeat this procedure or contact your next level of support.

Letter F

LNW2 SYSCTL faceplate latches are not fully seated.

Unseat the LNW2 SYSCTL and repeat this procedure, properly seating the faceplate latch.

alternating N and O and x

“x” indicates that the NVM socket (1 or 2) is empty of the NVM installed is failed. Replace the indicated NVM or find another LNW2 SYSCTL equipped with two factory-installed NVMs and repeat this procedure.

Letter U

LNW2 SYSCTL will not boot due to unexpected or unreadable shelf type.

Repair the problem generally caused by bent pins and repeat this procedure.

flashing b

Boot in progress.

A red, four-segment square (2 x 2) appears in the IND display on the LNW2 SYSCTL.

Acknowledges the UPD/INIT button was momentarily pushed.

Pushing the UPD/INIT button while in Maintenance Mode has no effect.


End of steps