In addition to the equipment listed in Required equipment, the following equipment is also required:
Prior to performing this procedure:
Refer to Before you begin in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to isolate and clear a fan failure.
1 |
Is the power indicator (PWR ON) LED lighted on the Alcatel-Lucent 1665 DMXtend fan shelf?
| ||||||||
2 |
The Fan Shelf has no power. Check power and alarm cables. If cables are not connected, install power and alarm cables to Fan Shelf and tighten screw locks. | ||||||||
3 |
Is Fan Shelf running and working properly (PWR ON LED lighted, FAULT LED off, CLOGGED FILTER LED off)? The Alcatel-Lucent 1665 DMXtend Fan Shelf needs four fans operating to provide the minimum required airflow.
| ||||||||
4 |
Replace the fan filter. Reference: Procedure 6-15: Replace fan filter | ||||||||
5 |
Is Fan Shelf running and working properly (PWR ON LED lighted, FAULT LED off, CLOGGED FILTER LED off)?
| ||||||||
6 |
Unscrew the screw locks and disconnect power and alarm cable from fan unit on the Alcatel-Lucent 1665 DMXtend shelf | ||||||||
7 |
Back out the screws securing the fan unit. Figure 5-1, Alcatel-Lucent 1665 DMXtend fan unit screws illustrates the location of the screws on the Alcatel-Lucent 1665 DMXtend shelf. Figure 5-1: Alcatel-Lucent 1665 DMXtend fan unit screws![]() | ||||||||
8 |
Slide the old fan unit out from the fan chassis. | ||||||||
9 |
Slide the new fan unit back into the fan chassis. Tighten all screws located in the front of the fan unit for the Alcatel-Lucent 1665 DMXtend shelf. Hand tighten the #4 steel thread fasteners until "snug tight" and then 1/2 turn with a wrench/screwdriver (torque should be approximately 8 in-lb.). | ||||||||
10 |
Reconnect the power and alarm cables to the back of the fan unit. End of steps |