Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a version mismatch alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the version mismatch alarm in the resulting alarm list. | ||||||
2 |
Refer to the Probable Cause column in the alarm list, determine the affected circuit pack, and note the corresponding AID. | ||||||
3 |
Un-seat and then re-seat the alarmed circuit pack. Result: The SYSCTL reinitializes the affected circuit pack and should automatically update the firmware on the newly installed circuit pack. | ||||||
4 |
From the System View, click the Alarm List button and click Refresh. | ||||||
5 |
Is the version mismatch alarm still present?
| ||||||
6 |
From the System View, select Configuration → Software → Apply Software to schedule a Smart or Smart, Override Alarms software apply. Result: Approximately 15 minutes after the scheduled apply time, the apply is complete. You will be logged off the system when the system resets. A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing. Reference: Procedure 6-20: Apply software generic | ||||||
7 |
Log back into the shelf. | ||||||
8 |
From the System View, click the Alarm List button and click Refresh. | ||||||
9 |
Is the version mismatch alarm still present?
| ||||||
10 |
From the System View, select Configuration → Software → Apply Software to schedule a Forced software apply. Result: Approximately 15 minutes after the scheduled Forced apply time, the apply is complete. You will be logged off the system when the system resets. A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing. Reference: Procedure 6-20: Apply software generic | ||||||
11 |
Log back into the shelf. | ||||||
12 |
From the System View, click the Alarm List button and click Refresh. | ||||||
13 |
Is the version mismatch alarm still present?
| ||||||
14 |
Un-seat and then re-seat the SYSCTL, then repeat this procedure from Step 6. | ||||||
15 |
Are there any alarms listed?
End of steps |