Use this procedure to upgrade the software generic from Release 6.0.x, 7.0.x, or 7.1.x, 7.2.x to Release 7.2 on a shelf without TCP/IP connectivity using FTTD (FTP-FTAM gateway).
Important!
When performing this software upgrade, you may experience transmission hits within typical protection switch times (up to 60 ms).
To download the software generic to a local shelf using SFTP, refer to Procedure 2-5: Software generic download and upgrade using SFTP.
To download the software generic to a local shelf using FTP, refer to Procedure 2-6: Software generic download and upgrade using FTP.
To download the software generic to a local or remote shelf using FTAM, refer to Procedure 2-8: Software generic download and upgrade using FTAM.
You must log in as a Privileged user to complete this procedure.
In addition to Required equipment listed in this chapter, the following equipment is also required:
CAT5 Ethernet cable with either a 10/100 hub or a cross-over cable for the LAN port.
Copy of the new system generic software program on your PC or FTP server.
Current Alcatel-Lucent 1850 Transport Service Switch (TSS-5) Release 7.2.X Customer Release Notes for the software generic being installed.
Important!
If the FTP server fails to start, it could mean that another program using an FTP server is already running. Depending on what operating system you are using, you must go to the device file and disable the FTP server. Refer to Procedure 14-14: Disable an FTP server on your PC for instructions for each allowed operating system.
Prior to performing this procedure:
Refer to Before you begin in this chapter and Electrostatic discharge in Chapter 1, Safety.
Verify that the new software generic program is available.
Refer to the Alcatel-Lucent 1850 Transport Service Switch (TSS-5) Release 7.2.X Customer Release Notes for the software being downloaded for a description of any special considerations involving this version of software.
This procedure uses FTP (file transfer protocol) and FTAM-FTP gateway/file transfer translation device (FTTD) to download software to a shelf. FTTD allows Alcatel-Lucent 1850 TSS-5 to function as a gateway network element (GNE) that facilitates file downloads between FTP servers and remote network elements (RNEs) connected to the Alcatel-Lucent 1850 TSS-5.
If you log in using TCP/IP, your PC must be part of the GNE's TCP/IP Gateway Host List. Refer to Procedure 7-14: Provision/enable/disable the NE as a TL1 TCP/IP GNE .
Complete the following steps to download system software using FTTD.
1 |
Connect the PC and establish a WaveStar® CIT session to the gateway Network Element. Important! You must login using either OSI or TCP/IP. Reference: Procedure 14-2: Connect personal computer (PC) and establish WaveStar® CIT session | ||||||
2 |
From the System View menu, select View → Software Generic. | ||||||
3 |
Is the Active Software Version 6.0.x or later?
| ||||||
4 |
From the System View menu, select Administration → View NE Administration. Verify that File Transfer Protocol (FTP) and FTAM-FTP (FTTD) Gateway Control are ENABLED and click Close. | ||||||
5 |
If required, select Administration → Set NE and enable File Transfer Protocol (FTP) and FTAM-FTP (FTTD) Gateway Control. Click OK. | ||||||
6 |
Is your remote NE in the same OSI area as your gateway NE?
| ||||||
7 |
From the System View, select Administration → Data Communications. Select the Network Layer tab and record the NSAP from the Network Service Access Point panel (the NSAP is a 40-digit hex number). This NSAP is required later in this procedure. | ||||||
8 |
Establish a WaveStar® CIT session to the remote Network Element to which you wish to download the NE software generic. Reference: Procedure 14-2: Connect personal computer (PC) and establish WaveStar® CIT session | ||||||
9 |
From the System View menu, select Configuration → Software → Download Software. Result: The Download Software window opens. | ||||||
10 |
In the pull-down Download From/Via: menu, select FTTD and verify that the FTTD tab is selected. | ||||||
11 |
Define the FTAM-FTP Gateway in one of the following ways:
| ||||||
12 |
Select the FTP tab. | ||||||
13 |
Select a connection profile from the Profile pull-down menu and then proceed to Step 15. OR Enter information for a new profile as follows:
| ||||||
14 |
If you entered connection information in Step 13 and wish to keep the information for future backups:
Important! Entries to the Profile pull-down menu may be changed using the Modify, Apply, and Save buttons or removed using the Delete button. | ||||||
15 |
In the Source/Destination Directory Path panel, enter the current location of the generic to be downloaded or use the Browse button (if available) to select the generic to be downloaded. If the FTP server is not the local host, the Browse button is greyed out. The value of the Path field can be either an absolute path or a relative path that is relative to the FTP server root directory.
If necessary, replace 7.2.2 with your current release, for example 7.2.3. If the FTP server is not the WaveStar® CIT, then enter the path starting at the FTP home directory on the server. | ||||||
16 |
Click OK. Result: A warning message appears indicating the transfer you are about to execute. Do you wish to continue? Verify the information and click Yes. While the download is in progress, a Progress Indicator window is present. The download takes approximately 5 minutes. The download may be cancelled any time by clicking Cancel on the Progress Indicator window. When the transfer is complete, the Progress Indicator window closes and the download software successful screen appears. Click OK. | ||||||
17 |
Is the WaveStar® CIT your FTP server and do you wish to observe the FTP download progress?
| ||||||
18 |
Important! Do NOT insert a new circuit pack in the shelf until after you apply the new software generic and clear the dormant/exec version mismatch condition. Do you wish to apply (activate) the software generic that you recently downloaded to the dormant area of the Alcatel-Lucent 1850 TSS-5 shelf?
| ||||||
19 |
Do you wish to upgrade additional shelves using FTTD?
End of steps |