Use this procedure to perform a private line Ethernet terminal loopback transmission test on the VLNC35 Fast Ethernet Private Line circuit pack. It is assumed that the Fast Ethernet service has been configured using the procedures in this chapter.
Important!
The following rules apply for this test:
Prior to performing this task, refer to Before you begin and Required equipment in this chapter and you must have complete work instructions for this task that detail:
You must have an Ethernet test set capable of applying the external test signal required for this task.
Use the following procedure to perform a private line Ethernet terminal loopback transmission test on the VLNC35 Fast Ethernet Private Line circuit pack:
1 |
Use the WaveStar® CIT to log in to the near end Alcatel-Lucent 1850 TSS-5 shelf. Reference: Procedure 14-2: Connect personal computer (PC) and establish WaveStar® CIT session |
2 |
Review the following test set considerations:
|
3 |
Connect the near end port to the Ethernet test set and start sending traffic to the other end. |
4 |
For the circuit being tested, perform a terminal loopback at the far-end node port. Select Fault → Analysis → Port Loopback from the System View menu at the far-end node. Expand the circuit pack details, select the port, then click Select at the bottom of the screen. |
5 |
Verify the port AID, then click the Operate. Click on Apply at the bottom of the window. Read the warning message, then click Yes to operate the command. |
6 |
Verify traffic is being received at the source node Ethernet test set. |
7 |
Use the Fault → Analysis → Port Loopback command to release the loopback. Repeat this procedure for all circuits being tested. End of steps |