Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an unexpected or failed Pluggable Transmission Module/underlying resources unavailable, optical module alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the unexpected or failed Pluggable Transmission Module/underlying resources unavailable, optical module alarm in the resulting alarm list. | ||||||||
2 |
Determine the alarm level(s) for the active unexpected or failed Pluggable Transmission Module/underlying resources unavailable, optical module alarm(s). Clear the alarms in order of severity. | ||||||||
3 |
Refer to the Probable Cause column in your alarm list, and determine the pluggable transmission module affected and note the corresponding socket AID. | ||||||||
4 |
Was the affected pluggable transmission module just installed in the socket?
| ||||||||
5 |
Select Reports → Status Lists → Pluggable Transmission Module to obtain the Pluggable Module Status showing the expected pluggable transmission module for the affected circuit pack/socket. | ||||||||
6 |
Use the Pluggable Module Status and office records to verify that the correct pluggable transmission module was installed in the correct socket/circuit pack.
End of steps |