Appendix: 7210 SAS boot procedures
This chapter describes the booting procedures for 7210 SAS devices.
This chapter provides information about booting a factory-shipped 7210 SAS device for the first time. It also includes information to boot the 7210 SAS device after subsequent reboots that are initiated by issuing the admin reboot command. For subsequent reboots, the BOF and the TiMOS image are stored on the local flash.
The 7210 SAS supports two modes for a first-time boot of a factory-shipped node or to boot the node after the admin>reboot auto-init command is executed. The supported boot modes are:
auto-init mode
In this mode, the boot procedure uses an external DHCP server to provide the IP address and other IP parameters, and the BOF configuration, which contains the image location and the configuration file location. This mode does not require user intervention and provides an option for zero-touch provisioning of the node.
This method also provides an option to modify the default values of the BOF parameters used for auto-init and customize a specific set of BOF parameters so that auto-init is supported in the customer network environment. See Auto-init mode for a list of BOF parameters that the user can modify.
The user requires console access to modify BOF parameters. After the partial BOF is saved, the system continues using the auto-init mode procedure to boot, with auto-init using the modified values of the BOF parameters that the user has provided.
manual mode
In this mode, the boot procedure requires user intervention to complete the process. During the boot process, the user must log in to the console on the node and configure the IP address, other IP parameters, and the location of the image file and configuration file. The following options are supported to boot the 7210 SAS device in manual mode:
boot from the image on flash
boot from the network using uplink ports
boot from the network using the OOB Ethernet management port
The following table lists the supported boot procedures for 7210 SAS devices.
Section |
Description |
---|---|
This procedure uses the auto-init mode to boot the 7210 SAS device. |
|
This procedure uses the manual mode to boot the 7210 SAS device. In manual mode, the device can be booted from the local flash or it can be booted from the network using an uplink port or the OOB Ethernet management port. The following procedures apply:
|
|
This procedure uses the BOF that is present locally to boot the 7210 SAS device. |
|
This procedure boots the 7210 SAS device in the satellite mode. |
|
This procedure boots the 7210 SAS device in the standalone-VC mode. |
Console outputs shown in this chapter are examples only; actual displays may differ depending on the 7210 SAS platform, supported functionality, and user configuration.
Procedure to boot using auto-init mode
The auto-init mode is supported on all 7210 SAS platforms, except the 7210 SAS-R6, 7210 SAS-R12, and 7210 SAS platforms that are configured in the standalone-VC or satellite modes of operation.
This section describes the procedure to boot the 7210 SAS using the auto-init mode.
The auto-init mode is used to boot the 7210 SAS device in the following scenarios:
-
user boots the device for the first time
-
user boots the device after a reset to the factory default settings
-
user boots the device after the execution of the admin>reboot auto-init command
To boot using the auto-init mode requires a DHCP server to be configured in the network and reachable by the system. The 7210 SAS device uses the auto-init mode to obtain the BOF from the network using the IP address and file location provided by the DHCP server, and uses the parameters specified in the BOF to download the TiMOS image file and configuration file required to boot the node. See Auto-init mode for more information about the auto-init procedure and the DHCP parameters used.
Perform the following steps to boot the 7210 SAS device using the auto-init mode:
- Optional:
Connect the console port to the serial port of the PC and power on the 7210 SAS
device to display log messages generated on the screen.
Note:
This is an optional step. Perform this step only if you need to diagnose issues with the auto-init procedure, if any.
The system starts booting and the following console output is displayed.
Nokia 7xxx Boot ROM. Copyright 2000-2020 Nokia. All rights reserved. All use is subject to applicable license agreements. Build: X-20.3.B1-1 on Wed Feb 12 15:29:52 IST 2020 by sasbuild Version: 0x38 Processor core is CN66xx COLD boot on processor #1 ?Preparing for jump to RAM... Starting bootrom RAM code... Boot rom version is v56 CPU #1 booted from working sector CPU Control FPGA version is 0x3D FPGA A version is 0x3D. FPGA B version is 0x3D. FPGA C version is 0x3D. Restart type = 0x01 >>>Validate SDRAM from 0x000000007fdfff80 to 0x0000000080000000 (decrementing) >>>Testing SDRAM from 0x0000000002200000 to 0x000000007fdfff80 >>>Testing SDRAM from 0xffffffffe0000000 to 0xffffffffe2000000 Power on Diagnostics passed Board Serial Number is 'NS1715T0019' Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-V-20.3.B1-1 bootrom/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:28:49 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/m Searching for boot.tim on local drives: Attempting to load file cf1:/boot.tim Version L-20.3.B1-1, Wed Feb 12 15:31:09 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(13818400-->40990080) + data:(3162656-->19580220) Starting at 0x18000000... Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-L-20.3.B1-1 boot/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:31:09 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/ main TiMOS BOOT LOADER Time from clock is WED MAR 04 09:23:22 2020 UTC Switching serial output to sync mode... done Chassis-role is set to : factory-default
- The system lists the default settings and the following console output is
displayed.
Looking for cf1:/bof.cfg ... OK, reading Contents of Boot Options File on cf1: #eth-mgmt Port Settings: eth-mgmt-disabled #uplinkA Port Settings: uplinkA-port 1/1/65 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 100000 uplinkA-address 0 uplinkA-vlan 0 #uplinkB Port Settings: uplinkB-port 1/1/66 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 100000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 no console-disabled Hit a key within 1 second to change boot parameters...
- At the prompt, wait until the specified wait time has elapsed. The system will
direct DHCP requests from the uplink ports to reach a DHCP server.
The following console output is displayed.
Trying DHCP on Port 1/1/65 (Priority tagged) Chassis MAC Address: D0:99:D5:97:02:41 DHCP failed on Port 1/1/65 Failure reason: SFP not present on port Trying DHCP on Port 1/1/65 (Untagged) Chassis MAC Address: D0:99:D5:97:02:41 DHCP failed on Port 1/1/65 Failure reason: SFP not present on port Trying DHCP on Port 1/1/66 (Priority tagged) Chassis MAC Address: D0:99:D5:97:02:41 DHCP failed on Port 1/1/66 Failure reason: SFP not present on port Trying DHCP on Port 1/1/66 (Untagged) Chassis MAC Address: D0:99:D5:97:02:41 DHCP failed on Port 1/1/66 Failure reason: SFP not present on port Trying DHCP on Port 1/1/67 (Priority tagged) Chassis MAC Address: D0:99:D5:97:02:41 Port 1/1/67, Speed:100000, Duplex:Full, Link:Up. DHCP failed on Port 1/1/67 Trying DHCP on Port 1/1/67 (Untagged) Chassis MAC Address: D0:99:D5:97:02:41 Port 1/1/67, Speed:100000, Duplex:Full, Link:Up. DHCP Server:192.168.2.8 Boot device addr: 192.168.2.9 Subnet mask: 24 Boot host: 192.168.2.8 Url from Boot file: tftp://192.168.2.8/images-pf/SASS/voy/bof.cfg Initial DNS resolving preference is ipv4-only
- The DHCP server responds to the system request and supplies an IP address, default
gateway information, and a BOF location.
The following console output is displayed.
Looking for tftp://192.168.2.8/images-pf/SASS/voy/bof.cfg ... OK, reading Successfully saved the new settings in cf1:/bof.cfg
- The system applies the IP configuration and downloads the BOF from the location
specified by the DHCP server. The BOF is saved on the flash drive.
The 7210 SAS device initiates the boot using the BOF, and the following console output is displayed.
My New Settings ------------ primary-image ftp://*:*@192.168.2.8/./images-pf/SASS/voy/hops-both.tim primary-config ftp://*:*@192.168.2.8/./images-pf/SASS/voy/dut-h.cfg #eth-mgmt Port Settings: no eth-mgmt-disabled eth-mgmt-address 192.168.2.9/24 active eth-mgmt-route 192.250.0.0/16 next-hop 192.168.2.8 eth-mgmt-autoneg eth-mgmt-duplex full eth-mgmt-speed 100 #System Settings: wait 3 persist off console-speed 115200 no console-disabled host-type standalone Setting the chassis role to standalone. Configuring Network with eth-mgmt Port Setting..... Primary config file location: ftp://*:*@192.168.2.8/./images-pf/SASS/voy/dut-h.cfg Initial DNS resolving preference is ipv4-only Downloading 'ftp://*:*@192.168.2.8/./images-pf/SASS/voy/dut-h.cfg'...OK Sap Index file location: ftp://*:*@192.168.2.8/./images-pf/SASS/voy/dut-h.sdx Downloading 'ftp://*:*@192.168.2.8/./images-pf/SASS/voy/dut-h.sdx'...OK Primary image location: ftp://*:*@192.168.2.8/./images-pf/SASS/voy/hops-both.tim Initial DNS resolving preference is ipv4-only Loading image ftp://*:*@192.168.2.8/./images-pf/SASS/voy/hops-both.tim Version B-20.3.B1-1, Wed Feb 12 15:33:08 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(41664192-->183719312)
- After the 7210 SAS
device boots up, the following login prompt is
displayed.
All rights reserved. All use subject to applicable license agreements. Built on Wed Apr 20 14:32:04 IST 2011 by builder in /builder/3.0B5/panos/main Login:
- At the prompt, enter admin for the default username and password, and log in to the 7210 SAS device.
Procedures to boot using manual mode
The manual mode is supported on all 7210 SAS platforms, except those operating in satellite mode.
This section describes the procedures to boot the 7210 SAS from the network or flash using the manual mode.
The manual mode can be used to boot the 7210 SAS device in the following scenarios:
user boots the device for the first time
user boots the device after a reset to the factory default settings, or after executing the admin>reboot auto-init command (this command is not supported on the 7210 SAS-R6 and 7210 SAS-R12, and 7210 SAS platforms configured in the standalone-VC mode of operation)
In all scenarios, the user must create a local BOF by connecting a console to the node and interrupting the boot process to configure the BOF parameters. The following sections provide the details for configuring the BOF parameters under different scenarios.
The manual mode has two options:
7210 SAS device is booted from the local image on flash; see section Procedure to boot from the image on flash in manual mode (supported on all 7210 SAS platforms, except those operating in the satellite mode)
7210 SAS device is booted from the network using an uplink port (section Procedure to boot from the network in manual mode using uplink ports; supported on all 7210 SAS platforms, except the 7210 SAS-R6 and 7210 SAS-R12) or the Ethernet management port (section Procedure to boot from the network in manual mode using the OOB Ethernet management port; supported on all 7210 SAS platforms when the Ethernet management port is available)
Procedure to boot from the image on flash in manual mode
This procedure is not supported for 7210 SAS platforms configured in the satellite mode of operation.
7210 SAS platforms that are factory-shipped with the boot.tim and both.tim (TiMOS image) on the internal flash attempt to boot using the auto-init mode when they are booted for the first time from factory. If the auto-init mode fails, the node loads with the image on the flash. If the user wants to continue using this image, they must connect to a console and execute the admin auto-init stop command in the TiMOS prompt. If the user does not execute this command, the device reboots and attempts the auto-init mode procedure again.
For the 7210 SAS-Dxp, 7210 SAS-K 2F1C2T, 7210 SAS-K 2F6C4T, 7210 SAS-K 3SFP+ 8C, 7210 SAS-Mxp, 7210 SAS-R6, 7210 SAS-R12, 7210 SAS-Sx/S 1/10GE, 7210 SAS-Sx 10/100GE, and 7210 SAS-T, the user must buy a software license that is factory-shipped with the TiMOS image on a flash or SD card device. The user must plug the flash or SD card device in the designated slot for the external flash or SD card device and power on the unit.
See the corresponding 7210 SAS chassis installation guide for information about equipment required to setup the device.
Perform the following steps to boot the system in the manual mode from the local image on the flash:
-
Connect the 7210 SAS
console port to the serial port of the PC, and power on the 7210 SAS
device. The system starts booting and the following console output is displayed.
Nokia 7xxx Boot ROM. Copyright 2000-2020 Nokia. All rights reserved. All use is subject to applicable license agreements. Build: X-20.3.B1-1 on Wed Feb 12 15:29:52 IST 2020 by sasbuild Version: 0x38 Processor core is CN66xx COLD boot on processor #1 ?Preparing for jump to RAM... Starting bootrom RAM code... Boot rom version is v56 CPU #1 booted from working sector CPU Control FPGA version is 0x3D FPGA A version is 0x3D. FPGA B version is 0x3D. FPGA C version is 0x3D. Restart type = 0x01 >>>Validate SDRAM from 0x000000007fdfff80 to 0x0000000080000000 (decrementing) >>>Testing SDRAM from 0x0000000002200000 to 0x000000007fdfff80 >>>Testing SDRAM from 0xffffffffe0000000 to 0xffffffffe2000000 Power on Diagnostics passed Board Serial Number is 'NS1720T0009' Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-V-20.3.B1-1 bootrom/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:28:49 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/m Searching for boot.tim on local drives: Attempting to load file cf1:/boot.tim Version L-20.3.B1-1, Wed Feb 12 15:31:09 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(13818400-->40990080) + data:(3162656-->19580220) Starting at 0x18000000... Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-L-20.3.B1-1 boot/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:31:09 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/ main TiMOS BOOT LOADER Time from clock is SUN MAR 15 15:19:08 2020 UTC Switching serial output to sync mode... done Chassis-role is set to : factory-default
- The system lists the default settings and the following console output is
displayed.
Looking for cf1:/bof.cfg ... OK, reading Contents of Boot Options File on cf1: #eth-mgmt Port Settings: eth-mgmt-disabled #uplinkA Port Settings: uplinkA-port 1/1/65 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 100000 uplinkA-address 0 uplinkA-vlan 0 #uplinkB Port Settings: uplinkB-port 1/1/66 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 100000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 no console-disabled Hit a key within 3 seconds to change boot parameters...
-
At the prompt, press any key to initiate boot parameter updates. The following console
output is displayed.
Enter password to edit the Boot Options File Or CTRL-D to exit the prompt Waiting for 30 seconds to enter password Password:
- At the prompt, enter the default password password, and
initiate the BOF edit.
The system accepts the password and the following console output is displayed.
You must supply some required Boot Options. At any prompt, you can type: "restart" - restart the query mode. "reboot" - reboot. "exit" - boot with with existing values. "diag" - enter the diag shell. "reset" - reset the bof and reboot. Press ENTER to begin, or 'flash' to enter firmware update...
- At the prompt, press Enter to edit the BOF. The following
console output is displayed.
Chassis-Role ------------- Current chassis-role is : factory-default You can change it to { satellite | standalone }. Press ENTER to continue OR "edit" to change the chassis-role : Chassis-role is set to factory-default, Do you wish to continue with this (yes/no) :
- At the prompt, enter yes. The following console output is
displayed.
Software Location ----------------- You must enter the URL of the TiMOS software. The location can be on a Compact Flash device, a USB flash drive, or on the network. Here are some examples cf1:/timos1.0R1 uf1:/timos1.0R1 ftp://user:passwd@192.168.1.150/./timos1.0R1 ftp://user:passwd@[3FFE::1]/./timos1.0R1 or Type 'auto' to retrieve BOF configuration through DHCP. Software Image URL:
-
At the prompt, enter the location of the image.
In factory-shipped 7210 SAS devices, the image is typically available at cf1:\both.tim or cf2:\both.tim.
The following console output is displayed.
Configuration File Location --------------------------- You must enter the location of configuration file to be used by TiMOS. The file can be on a Compact Flash device, a USB flash drive, or on the network. Here are some examples uf1:/config.cfg cf1:/config.cfg ftp://user:passwd@192.168.1.150/./config.cfg ftp://user:passwd@[3FFE::1]/./config.cfg tftp://192.168.1.150/./config.cfg tftp://[3FFE::1]/./config.cfg Config File URL:
- Enter the location of the configuration file, or press Enter
to skip this step.
The following console output is displayed.
Current configuration enables use of console (setting is "no console-disabled") Press ENTER to proceed with existing setting or 'disable' to disable console access :
- At the prompt, press Enter. The following console output is
displayed.
New Settings ------------ primary-image cf2:/both.tim primary-config uf1:/sassx64.cfg #eth-mgmt Port Settings: eth-mgmt-disabled #uplinkA Port Settings: uplinkA-port 1/1/65 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 100000 uplinkA-address 0 uplinkA-vlan 0 #uplinkB Port Settings: uplinkB-port 1/1/66 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 100000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 no console-disabled Do you want to overwrite cf1:/bof.cfg with the new settings? (yes/no):
- At the prompt, enter yes. The 7210 SAS
device begins to boot with the new settings. The following console output is
displayed.
Successfully saved the new settings in cf1:/bof.cfg Configuring Network with uplinkA Port Setting..... Primary config file present at: uf1:/sassx64.cfg Skipping missing or bad Sap index file 'uf1:/sassx64.sdx' Primary image location: cf2:/both.tim Loading image cf2:\both.tim Version B-20.3.B1-1, Wed Feb 12 15:33:08 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(41664192-->183719312) + data:(7133216-->49945144) Executing TiMOS image at 0x2800000
- After the 7210 SAS
device boots up, the following login prompt is
displayed.
All rights reserved. All use subject to applicable license agreements. Built on Wed Apr 20 14:32:04 IST 2011 by builder in /builder/3.0B5/panos/main Login:
-
At the prompt, enter admin for the default username and
password, and log into the 7210 SAS
device.
Note:
The SYS LED is green after the device has successfully completed the boot process and is running normally.
Procedure to boot from the network in manual mode using uplink ports
This procedure is supported on all 7210 SAS platforms, except the 7210 SAS-R6 and 7210 SAS-R12, and all platforms configured in the satellite mode of operation.
Perform this procedure to boot a 7210 SAS device from the network without using the auto-init mode.
See the corresponding 7210 SAS chassis installation guide for information about equipment required to setup the device.
The front panel ports (referred to as uplinkA and uplinkB in the sample output used in this procedure) are used to boot the device from the network.
Nokia recommends that the TiMOS image should be stored on the internal flash so that it is available for use in the case where booting the system from the flash is required later on subsequent reboot.
Perform the following steps to boot from the network in the manual mode using uplink ports.
- Power on the 7210 SAS device.
- Use the uplink ports to boot from the
network.
Nokia SASDxp 7210 Boot ROM. Copyright 2000-2020 Nokia. All rights reserved. All use is subject to applicable license agreements. Build: X-20.3.B1-1 on Wed Feb 12 15:29:18 IST 2020 by sasbuild Version: 0x8 SASDxp-DC Board Shmoo tuning data in flash is valid, load it DDR Tuning Complete. Passed! Copying code from FLASH to RAM.... Done Board CPLD Version: 0x0e Reboot Reason: 0x05 Boot rom version is v8 >>> RAM: Testing DDR Passed! Board Serial Number is 'NS1917T0023' DDR Tuning Complete. Tuning values already saved. Skip saving to flash. Memory Test Passed! Jumping to vxrom at 0x61400000 now.................. ^[[6~^[[6~ Searching for boot.tim on local drives: Attempting to load file cf1:/boot.tim Version L-20.3.B1-1, Wed Feb 12 15:30:14 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(12972416-->39659312) + data:(4504352-->20039220) Starting at 0x6f000000... Total Memory: 2GB Chassis Type: 0xa Card Type: 0x4e TiMOS-L-20.3.B1-1 boot/ARMiproc Nokia SAS-Dxp 6T4F2SFP+ 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:30:14 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/m TiMOS BOOT LOADER Time from clock is SUN MAR 15 05:09:48 2020 UTC Switching serial output to sync mode... done
- The system lists the default settings and the following console output is
displayed.
Looking for cf1:/bof.cfg ... OK, reading Contents of Boot Options File on cf1: #uplinkA Port Settings: uplinkA-port 1/1/11 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 10000 uplinkA-address 0 uplinkA-vlan 0 #uplinkB Port Settings: uplinkB-port 1/1/12 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 10000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 uplink-mode access-uplink no console-disabled Hit a key within 1 second to change boot parameters...
-
At the prompt, press any key to initiate boot parameter updates. The following console
output is displayed.
Enter password to edit the Boot Options File Or CTRL-D to exit the prompt Waiting for 30 seconds to enter password Password:
-
At the prompt, enter the default password password. The system
accepts the password and the following console output is displayed.
You must supply some required Boot Options. At any prompt, you can type: "restart" - restart the query mode. "reboot" - reboot. "exit" - boot with with existing values. "diag" - enter the diag shell. "reset" - reset the bof and reboot. Press ENTER to begin, or 'flash' to enter firmware update...
- At the prompt, press Enter to initiate the update. The
following console output is displayed.
Software Location ----------------- You must enter the URL of the TiMOS software. The location can be on a Compact Flash device, or on the network. Here are some examples cf1:/timos1.0R1 ftp://user:passwd@192.168.1.150/./timos1.0R1 ftp://user:passwd@[3FFE::1]/./timos1.0R1 or Type 'auto' to retrieve BOF configuration through DHCP. Software Image URL:
-
At the prompt, enter the URL location of the software; for example,
ftp://<user>:<password>@10.10.170.22/./images/both.tim.
The following console output is displayed.
Configuration File Location --------------------------- You must enter the location of configuration file to be used by TiMOS. The file can be on a Compact Flash device, or on the network. Here are some examples cf1:/config.cfg ftp://user:passwd@192.168.1.150/./config.cfg ftp://user:passwd@[3FFE::1]/./config.cfg tftp://192.168.1.150/./config.cfg tftp://[3FFE::1]/./config.cfg Config File URL:
- At the prompt, enter the URL location of the configuration file. The following
console output is displayed.
Boot Interface Management ------------------------- You specified a network location for either the software or the configuration file. You need to configure either eth-mgmt or uplinkA or uplinkB ports. You will be asked to configure the port number, IP(v6) address, static routes, and VLAN Id in case of uplink ports. Existing uplinkA port settings are: uplinkA-port 1/1/11 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 10000 uplinkA-address 0 uplinkA-address 0 uplinkA-vlan 0 uplinkA port is configured for Boot Interface Management, Press ENTER to proceed with existing port settings Or "disable" to disable the port for Boot Interface Management Or "edit" to change the port settings:
- At the prompt, enter edit to change the port settings. The
following console output is
displayed.
Existing uplinkA port for Boot Interface Management is port 1/1/11. Press ENTER to keep it. Enter the new uplinkA port number for Boot Interface Management:
- At the prompt, enter the front-panel port that is connected to the network (for
example, 1/1/10). The following console output is
displayed.
Enter uplinkA speed and duplex settings:
- At the prompt, enter uplink port speed and duplex settings The following console
output is displayed.
Auto-Negotiation is currently disabled. Press ENTER to proceed with existing setting or 'auto' to enable auto-negotiation. auto Auto-negotiation will be enabled on uplinkA port. You need to configure the VLAN Id for this port VLAN Id can be between 0 to 4094. To send out packets with out any VLAN tags, type "null". Existing VLAN Id for uplinkA port is VLAN Id 0. Press ENTER to keep it. Enter the new VLAN Id for uplinkA port:
- At the prompt, perform one of the following.
- Enter null to send out packets without VLAN tags.
- Enter the a VLAN tag ID for the uplink port.
The following console output is displayed.
Using port 1/1/1 as uplinkA port for Boot Interface Management You need to assign an IP address for this port. The IP address should be entered in standard dotted-decimal form with a network length. example: 192.168.1.169/24 Or type "0" to obtain IP address and static route through DHCP. Existing IP address and static routes will be deleted. Enter uplinkA IP Address (Type 0 if none desired):
- At the prompt, enter the port IP address and mask that the device should use (for example, 10.135.4.172/10).
- Because the FTP server is on a different subnet, enter the IP routing information.
The following console output is
displayed.
You specified network locations which might require static routes to reach. You will be asked to enter static routes until all the locations become reachable. Static routes should be entered in the following format: prefix/mask next-hop ip-address example: 192.168.0.0/16 next-hop 192.168.1.254 Would you like to add a static route? (yes/no)
- At the prompt, type yes and press
Enter to add a static route.
Enter route:
- Enter a static route to the FTP server subnet (for example, 10.10.170.0/10 next-hop
10.135.4.1). The following console output is
displayed.
Existing uplinkB port settings are: uplinkB-port 1/1/12 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 10000 uplinkB-address 0 uplinkB-address 0 uplinkB-vlan 0 uplinkB port is configured for Boot Interface Management, Press ENTER to proceed with existing port settings Or "disable" to disable the port for Boot Interface Management Or "edit" to change the port settings:
- At the prompt, press Enter to proceed existing port settings.
The following console output is
displayed.
Current configuration enables use of console (setting is "no console-disabled") Press ENTER to proceed with existing setting or 'disable' to disable console access :
- At the prompt, press Enter to proceed with the existing
settings. The following console output is displayed.
New Settings ------------ primary-image ftp://*:*@192.254.173.17/usr/global/images/20.3/B1-1/7xxx/ bcmiproc-both.tim primary-config ftp://*:*@192.254.173.5/tmp/dxp/dxp2537.cfg #uplinkA Port Settings: uplinkA-port 1/1/1 uplinkA-autoneg uplinkA-duplex full uplinkA-speed 1000 uplinkA-address 10.135.25.37/24 uplinkA-vlan null uplinkA-route 192.0.0.0/8 next-hop 10.135.25.1 #uplinkB Port Settings: uplinkB-port 1/1/12 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 10000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 uplink-mode access-uplink no console-disabled Do you want to overwrite cf1:/bof.cfg with the new settings? (yes/no):
- Enter yes to overwrite the bof.cfg file.
The 7210 SAS
device starts booting. The following console output is
displayed.
Successfully saved the new settings in cf1:/bof.cfg Configuring Network with uplinkA Port Setting..... Primary config file location: ftp://*:*@192.254.173.5/tmp/dxp/dxp2537.cfg Initializing uplinkA port using IP addr 10.135.25.37. Port 1/1/1-->Mode:Fix-Cu, Speed:100, Duplex:Full Autoneg: On, Link:Up. Initial DNS resolving preference is ipv4-only Downloading 'ftp://*:*@192.254.173.5/tmp/dxp/dxp2537.cfg'...OK Sap Index file location: ftp://*:*@192.254.173.5/tmp/dxp/dxp2537.sdx Downloading 'ftp://*:*@192.254.173.5/tmp/dxp/dxp2537.sdx'...OK Primary image location: ftp://*:*@192.254.173.17/usr/global/images/20.3/B1-1/7xxx/ bcmiproc-both.tim Port 1/1/1-->Mode:Fix-Cu, Speed:100, Duplex:Full Autoneg: On, Link:Up. Initial DNS resolving preference is ipv4-only Loading image ftp://*:*@192.254.173.17/usr/global/images/20.3/B1-1/7xxx/bcmiproc- both.tim Version B-20.3.B1-1, Wed Feb 12 15:32:56 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(41388544-->175510640) + data:(6606080-->43372008) Executing TiMOS image at 0x60100000
- After the 7210 SAS
device boots up, the following login prompt is
displayed.
All rights reserved. All use subject to applicable license agreements. Built on Wed Apr 20 22:44:35 IST 2011 by builder in /builder/3.0B5/R4/panos/main Login:
- At the prompt, enter admin for the default username and
password, and log into the 7210 SAS device.Note:
The Sys LED is green when the device has successfully completed the boot process and is running normally.
Procedure to boot from the network in manual mode using the OOB Ethernet management port
This procedure is not supported for 7210 SAS platforms configured in the satellite mode of operation. This procedure is supported on all 7210 SAS platforms that are equipped with an OOB Ethernet management port.
Perform the following steps to boot from the network using the OOB Ethernet management port without using the auto-init mode.
- Power on the 7210 SAS device.
- Use the OOB Ethernet Management port to boot from the
network.
Nokia 7xxx Boot ROM. Copyright 2000-2020 Nokia. All rights reserved. All use is subject to applicable license agreements. Build: X-20.3.B1-1 on Wed Feb 12 15:29:52 IST 2020 by sasbuild Version: 0x38 Processor core is CN66xx COLD boot on processor #1 ?Preparing for jump to RAM... Starting bootrom RAM code... Boot rom version is v56 CPU #1 booted from working sector CPU Control FPGA version is 0x3D FPGA A version is 0x3D. FPGA B version is 0x3D. FPGA C version is 0x3D. Restart type = 0x01 >>>Validate SDRAM from 0x000000007fdfff80 to 0x0000000080000000 (decrementing) >>>Testing SDRAM from 0x0000000002200000 to 0x000000007fdfff80 >>>Testing SDRAM from 0xffffffffe0000000 to 0xffffffffe2000000 Power on Diagnostics passed Board Serial Number is 'NS1720T0009' Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-V-20.3.B1-1 bootrom/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:28:49 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/m Searching for boot.tim on local drives: Attempting to load file cf1:/boot.tim Version L-20.3.B1-1, Wed Feb 12 15:31:09 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(13818400-->40990080) + data:(3162656-->19580220) Starting at 0x18000000... Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-L-20.3.B1-1 boot/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:31:09 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/ main TiMOS BOOT LOADER Time from clock is THU MAR 12 17:12:50 2020 UTC Switching serial output to sync mode... done Chassis-role is set to : factory-default
- The system lists the default settings and the following console output is
displayed.
Looking for cf1:/bof.cfg ... OK, reading Contents of Boot Options File on cf1: primary-image ftp://*:*@192.254.173.3/tmp/sass/b/both.tim #eth-mgmt Port Settings: no eth-mgmt-disabled eth-mgmt-address 10.135.25.36/24 active eth-mgmt-route 192.0.0.0/8 next-hop 10.135.25.1 eth-mgmt-autoneg eth-mgmt-duplex full eth-mgmt-speed 100 #uplinkA Port Settings: uplinkA-port 1/1/65 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 100000 uplinkA-address 0 uplinkA-vlan 0 #uplinkB Port Settings: uplinkB-port 1/1/66 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 100000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 no console-disabled Hit a key within 3 seconds to change boot parameters...
- At the prompt, press any key to initiate boot parameter updates.
The following console output is displayed.
Enter password to edit the Boot Options File Or CTRL-D to exit the prompt Waiting for 30 seconds to enter password Password:
- At the prompt, enter the default password password.
The system accepts the password and the following console output is displayed.
You must supply some required Boot Options. At any prompt, you can type: "restart" - restart the query mode. "reboot" - reboot. "exit" - boot with with existing values. "diag" - enter the diag shell. "reset" - reset the bof and reboot. Press ENTER to begin, or 'flash' to enter firmware update...
- At the prompt, press Enter to initiate the update. The
following console output is displayed.
Chassis-Role ------------- Current chassis-role is : factory-default You can change it to { satellite | standalone }. Press ENTER to continue OR "edit" to change the chassis-role : Chassis-role is set to factory-default, Do you wish to continue with this (yes/no) :
- At the prompt, enter yes. The following console output is
displayed.
Software Location ----------------- You must enter the URL of the TiMOS software. The location can be on a Compact Flash device, or on the network. Here are some examples cf1:/timos1.0R1 ftp://user:passwd@192.168.1.150/./timos1.0R1 tftp://192.168.1.150/./timos1.0R1 Software Image URL:
- At the prompt, enter the URL location of the software; for example,
ftp://<user>:<password>@10.10.170.22/./images/both.tim.
The following console output is displayed.
Configuration File Location --------------------------- You must enter the location of configuration file to be used by TiMOS. The file can be on a Compact Flash device, or on the network. Here are some examples cf1:/config.cfg ftp://user:passwd@192.168.1.150/./config.cfg tftp://192.168.1.150/./config.cfg No existing Config URL Press ENTER, or type 'none' for no Config URL. Config File URL:
- At the prompt, enter none. The following console output is
displayed.
Boot Interface Management ------------------------- You specified a network location for either the software or the configuration file. You need to configure either eth-mgmt or uplinkA or uplinkB ports. You will be asked to configure the port number, IP(v6) address, static routes, and VLAN Id in case of uplink ports. Existing eth-mgmt port settings are: eth-mgmt-port eth-mgmt-address 10.135.25.36/24 eth-mgmt-address 0 eth-mgmt-route 192.0.0.0/8 next-hop 10.135.25.1 eth-mgmt port is configured for Boot Interface Management, Press ENTER to proceed with existing port settings Or "disable" to disable the port for Boot Interface Management Or "edit" to change the port settings:
- At the prompt, enter edit to change the port settings. The
following console output is
displayed.
You need to assign an IP address for this port. The IP address should be entered in standard dotted-decimal form with a network length. example: 192.168.1.169/24 The existing eth-mgmt IP address is 10.135.25.36/24. Press ENTER to keep it. Enter eth-mgmt IP Address (Type 0 if none desired):
- At the prompt, enter the port IP address and mask that the device should use (for
example, 10.135.4.172/10). The following console output is
displayed.
In case of an IPv6, the IPv6 address should be entered in standard colon hexadecimal notation with a prefix length. example: 3FFE::1/112 Enter eth-mgmt IPv6 Address (Type 0 if none desired):
- At the prompt, enter 0. The following console output is
displayed.
No eth-mgmt IPv6 Address configured You specified network locations which might require static routes to reach. You will be asked to enter static routes until all the locations become reachable. Static routes should be entered in the following format: prefix/mask next-hop ip-address example: 192.168.0.0/16 next-hop 192.168.1.254 A static route to the Primary Image exists: 192.0.0.0/8 next-hop 10.135.25.1 Do you want to keep it? (yes/no)
- At the prompt, enter no. The following console output is
displayed.
Enter route to Primary Image at 192.254.173.3:
- At the prompt, enter the static route for the specified primary image location. The
following console output is
displayed.
A static route to the Primary Config exists: 192.0.0.0/8 next-hop 10.135.25.1 Do you want to keep it? (yes/no)
- At the prompt, enter yes. The following console output is
displayed.
Enter route to Primary Config at 192.254.173.3 192.0.0.0/8 next-hop 10.135.25.1
- At the prompt, enter a static route for the specified primary configuration
location. The following console output is
displayed.
Would you like to add a static route? (yes/no)
- At the prompt, enter yes. The following console output is
displayed.
Enter ip route:
- At the prompt, enter a static route to the FTP server subnet (for example,
10.10.170.0/10 next-hop 10.135.4.1). The following console output is
displayed.
Would you like to add another static route? (yes/no)
- At the prompt, enter no. The following console output is
displayed.
Would you like to add another static IPv6 route?
- At the prompt, enter no. The following console output is
displayed.
Existing uplinkA port settings are: uplinkA-port 1/1/65 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 100000 uplinkA-address 0 uplinkA-address 0 uplinkA-vlan 0 uplinkA port is configured for Boot Interface Management, Press ENTER to proceed with existing port settings Or "disable" to disable the port for Boot Interface Management Or "edit" to change the port settings:
- At the prompt, enter disable to proceed with no backup link.
The following console output is
displayed.
Existing uplinkB port settings are: uplinkB-port 1/1/66 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 100000 uplinkB-address 0 uplinkB-address 0 uplinkB-vlan 0 uplinkB port is configured for Boot Interface Management, Press ENTER to proceed with existing port settings Or "disable" to disable the port for Boot Interface Management Or "edit" to change the port settings:
- At the prompt, enter disable to proceed with no backup link.
The following console output is displayed.
Current configuration enables use of console (setting is "no console-disabled") Press ENTER to proceed with existing setting or 'disable' to disable console access :
- At the prompt, press Enter. The following console output is
displayed.
New Settings ------------ primary-image ftp://*:*@192.254.173.3/tmp/sass/b/both.tim primary-config ftp://*:*@192.254.173.3/tmp/sass/sassx64.cfg #eth-mgmt Port Settings: no eth-mgmt-disabled eth-mgmt-address 10.135.25.36/24 active eth-mgmt-route 10.135.0.0/16 next-hop 10.135.25.1 eth-mgmt-route 192.0.0.0/8 next-hop 10.135.25.1 eth-mgmt-autoneg eth-mgmt-duplex full eth-mgmt-speed 100 #uplinkA Port Settings: uplinkA-port 1/1/65 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 100000 uplinkA-address 0 uplinkA-vlan 0 #uplinkB Port Settings: uplinkB-port 1/1/66 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 100000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 no console-disabled Do you want to overwrite cf1:/bof.cfg with the new settings? (yes/no):
- At the prompt, enter yes. The following console output is
displayed.
Successfully saved the new settings in cf1:/bof.cfg Configuring Network with eth-mgmt Port Setting..... Primary config file location: ftp://*:*@192.254.173.3/tmp/sass/sassx64.cfg Initial DNS resolving preference is ipv4-only Downloading 'ftp://*:*@192.254.173.3/tmp/sass/sassx64.cfg'...OK Sap Index file location: ftp://*:*@192.254.173.3/tmp/sass/sassx64.sdx Downloading 'ftp://*:*@192.254.173.3/tmp/sass/ sassx64.sdx'...Cannot open input file ftp://*:*@192.254.173.3/tmp/sass/sassx64.sdx 0 files copied Failed Primary image location: ftp://*:*@192.254.173.3/tmp/sass/b/both.tim Initial DNS resolving preference is ipv4-only Loading image ftp://*:*@192.254.173.3/tmp/sass/b/both.tim Version B-20.3.B1-1, Wed Feb 12 15:33:08 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(41664192-->183719312) + data:(7133216-->49945144) Executing TiMOS image at 0x2800000 ==================================================
- After the 7210 SAS
device boots up, the following login prompt is
displayed.
All rights reserved. All use subject to applicable license agreements. Built on Wed Apr 20 22:44:35 IST 2011 by builder in /builder/3.0B5/R4/panos/main Login:
- At the prompt, enter admin for the default username and
password, and log into the 7210 SAS device.Note:
The Sys LED is green when the device has successfully completed the boot process and is running normally.
Procedure to boot when the BOF is present locally
This section describes the procedure to boot the 7210 SAS after a reboot, when the BOF and image files are present locally, or when the node is shipped from factory with a BOF and an image on the flash.
See Contents shipped with the system on 7210 SAS for a list of factory-shipped contents for each 7210 SAS device.
- Execute a reboot of the 7210 SAS
device. The system starts booting and the following console output is displayed.
Resetting...OK Nokia 7xxx Boot ROM. Copyright 2000-2020 Nokia. All rights reserved. All use is subject to applicable license agreements. Build: X-20.3.B1-1 on Wed Feb 12 15:29:52 IST 2020 by sasbuild Version: 0x38 Processor core is CN66xx COLD boot on processor #1 ?Preparing for jump to RAM... Starting bootrom RAM code... Boot rom version is v56 CPU #1 booted from working sector CPU Control FPGA version is 0x3D FPGA A version is 0x3D. FPGA B version is 0x3D. FPGA C version is 0x3D. Restart type = 0x01 >>>Validate SDRAM from 0x000000007fdfff80 to 0x0000000080000000 (decrementing) >>>Testing SDRAM from 0x0000000002200000 to 0x000000007fdfff80 >>>Testing SDRAM from 0xffffffffe0000000 to 0xffffffffe2000000 Power on Diagnostics passed Board Serial Number is 'NS1715T0019' Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-V-20.3.B1-1 bootrom/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:28:49 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/m Searching for boot.tim on local drives: Attempting to load file cf1:/boot.tim Cannot open "cf1:/boot.tim". Attempting to load file cf2:/boot.tim Cannot open "cf2:/boot.tim". Attempting to load file uf1:/boot.tim Version L-20.3.B1-1, Wed Feb 12 15:31:09 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(13818400-->40990080) + data:(3162656-->19580220) Starting at 0x18000000... Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-L-20.3.B1-1 boot/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:31:09 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/ main TiMOS BOOT LOADER Time from clock is WED MAR 04 11:18:16 2020 UTC Switching serial output to sync mode... done Chassis-role is set to : standalone Looking for uf1:/bof.cfg ... OK, reading
- The system locates the BOF on a local drive. The system reads the contents of the
BOF and displays it on the console.
The following console output is displayed.
Contents of Boot Options File on uf1: primary-image uf1:\both.tim #eth-mgmt Port Settings: eth-mgmt-disabled #uplinkA Port Settings: uplinkA-port 1/1/67 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 100000 uplinkA-address 0 uplinkA-vlan 0 #uplinkB Port Settings: uplinkB-port 1/1/68 no uplinkB-autoneg uplinkB-duplex full uplinkB-speed 100000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 no console-disabled Hit a key within 1 second to change boot parameters...
- At the prompt, wait until the specified wait time has elapsed. The boot process can
be interrupted at the prompt if necessary to change the boot parameters (for example, the
image location). In this example, it is assumed that changes to the BOF are not
required.
The following console output is displayed.
Configuring Network with uplinkA Port Setting..... No existing config file URL Primary image location: uf1:\both.tim Loading image uf1:\both.tim Version B-20.3.B1-1, Wed Feb 12 15:33:08 IST 2020 by sasbuild in /home/sasbuild/ 20.3B1/panos/main text:(41664192-->183719312) + data:(7133216-->49945144) Executing TiMOS image at 0x2800000
- The system loads the TiMOS image and the 7210 SAS
device boots up. The following console output is
displayed.
Total Memory: 2GB Chassis Type: 0xa Card Type: 0x43 TiMOS-B-20.3.B1-1 both/hops Nokia SAS-Sx 64SFP+4QSFP28 7210 Copyright (c) 2000- 2020 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 12 15:33:08 IST 2020 by sasbuild in /home/sasbuild/20.3B1/panos/ main Running 32 bit architecture Time from clock is WED MAR 04 11:19:24 2020 UTC Login:
- At the prompt, enter admin for the default username and password, and log in to the 7210 SAS device.
Procedure to boot in the satellite mode
See Supported modes of operation and configuration methods for the list of 7210 SAS platforms that support the satellite mode of operation.
See System boot options for 7210 SAS-Mxp, 7210 SAS-Sx 1/10GE, 7210 SAS-S 1/10GE, and 7210 SAS-Sx 10/100GE in satellite mode for information about the satellite mode on 7210 SAS devices.
See the specific 7210 SAS chassis installation guide for more information about prerequisites to boot the system in the satellite mode of operation.
Perform the following steps to boot the 7210 SAS device in the satellite mode of operation.
- Configure the 7750 SR
host with the 7210 SAS
both.tim image location (the software repository).
- Configure the Ethernet satellite on the 7750 SR
host.
See Uplink ports used for 7210 SAS platforms and variants in satellite mode for information about uplink ports used on 7210 SAS platforms operating in the satellite mode.
Note:In this example, the 7210 SAS device is identified by satellite ID 1 and its type is set to es64-10gb-sfpp+4-100gb-qsfp28. The satellite identifier (that is, esat-1, in this example) is used to refer to the entire satellite node when configuring services on the 7750 SR host.
- On the 7750 SR
host, configure the port connected to the 7210 SAS
device:Note: See System boot options for 7210 SAS-Mxp, 7210 SAS-Sx 1/10GE, 7210 SAS-S 1/10GE, and 7210 SAS-Sx 10/100GE in satellite mode for more information about port numbers for the 7210 SAS-Sx 10/100GE operating in satellite mode.
- Power on the Ethernet satellite:
Procedure to boot in the standalone-VC mode
This procedure is only supported on the 7210 SAS-S 1/10GE, 7210 SAS-Sx 1/10GE, and their variants.
See Provisioning and booting up the VC in standalone mode for more information.
Perform the following steps to boot the 7210 SAS device in the standalone-VC mode of operation:
- Power on the 7210 SAS device.
- Use the OOB Ethernet management port to boot form the network.
A:NS1722T0086# admin reboot now Resetting...OK Nokia SAS-S 7210 Boot ROM. Copyright 2000-2018 Nokia. All rights reserved. All use is subject to applicable license agreements. Build: X-11.0.B1-6 on Thu Dec 6 15:22:31 IST 2018 by sasbuild Version: 0x1F DRAM test first stage ?Boot rom version is v31 CPLD Version: 0x0C Board Serial Number is 'NS1722T0086' DRAM test second stage >>>Testing SDRAM from 0x0000000002200000 to 0x0000000080000000 >>>Testing SDRAM from 0xffffffffe0000000 to 0xffffffffe2000000 Loading VxRom image ....... Board Serial Number is 'NS1722T0086' Total Memory: 2GB Chassis Type: 0xa Card Type: 0x14 TiMOS-V-11.0.B1-6 bootrom/hops Nokia SAS-S 24T4SFP+ 7210 Copyright (c) 2000- 2018 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Thu Dec 6 15:21:48 IST 2018 by sasbuild in /home/sasbuild/11.0B1/panos/main Searching for boot.tim on local drives: Attempting to load file cf1:/boot.tim Version L-11.0.B1-21, Wed Feb 27 12:30:02 IST 2019 by sasbuild in /home/sasbuild/ 11.0B1/panos/main text:(13790784-->40910320) + data:(3160736-->19576100) Starting at 0x18000000... Total Memory: 2GB Chassis Type: 0xa Card Type: 0x14 TiMOS-L-11.0.B1-21 boot/hops Nokia SAS-S 24T4SFP+ 7210 Copyright (c) 2000- 2019 Nokia. All rights reserved. All use subject to applicable license agreements. Built on Wed Feb 27 12:30:02 IST 2019 by sasbuild in /home/sasbuild/11.0B1/panos/ main TiMOS BOOT LOADER Time from clock is SAT JAN 01 00:15:24 2000 UTC Switching serial output to sync mode... done Chassis-role is set to : standalone
- The system lists the default settings and the following console output is
displayed.
Looking for cf1:/bof.cfg ... OK, reading Contents of Boot Options File on cf1: #eth-mgmt Port Settings: eth-mgmt-disabled #uplinkA Port Settings: uplinkA-port 1/1/27 no uplinkA-autoneg uplinkA-duplex full uplinkA-speed 10000 uplinkB-address 0 uplinkB-vlan 0 #System Settings: wait 3 persist off console-speed 115200 no console-disabled Hit a key within 3 seconds to change boot parameters...
- At the prompt, press any key to initiate boot parameter updates.
The following console output is displayed.
Enter password to edit the Boot Options File Or CTRL-D to exit the prompt Waiting for 30 seconds to enter password Password:
- At the prompt, enter the default password password, and
initiate the BOF edit.
The system accepts the password and the following console output is displayed.
You must supply some required Boot Options. At any prompt, you can type: "restart" - restart the query mode. "reboot" - reboot. "exit" - boot with with existing values. "diag" - enter the diag shell. "reset" - reset the bof and reboot. Press ENTER to begin, or 'flash' to enter firmware update...
- At the prompt, press Enter to edit the BOF. The following
console output is displayed.
Chassis-Role ------------- Current chassis-role is : standalone You can change it to { satellite | standalone-vc | factory-default }. Press ENTER to continue OR "edit" to change the chassis-role : standalone-vc Press "edit" to change OR ENTER to continue :
- At the prompt, enter edit. The following console output is
displayed.
Enter the new chassis-role { satellite | standalone-vc | factory- default } :
- At the prompt, enter standalone-vc for the chassis-role. The
following output is
displayed.
Are you sure you want to set the chassis-role as standalone-vc? (yes/no) :
- At the prompt, enter yes. The following console output is
displayed.
Looking for cf1:/bof.cfg ... OK, reading Contents of Boot Options File on cf1: #eth-mgmt Port Settings: no eth-mgmt-disabled eth-mgmt-autoneg eth-mgmt-duplex full eth-mgmt-speed 100 #System Settings: wait 3 persist off console-speed 115200 no console-disabled vc-stack-node-type imm-only Hit a key within 2 seconds to change boot parameters...
- At the prompt, press any key to initiate boot parameter updates.
The following console output is displayed.
Enter password to edit the Boot Options File Or CTRL-D to exit the prompt Waiting for 30 seconds to enter password Password:
- At the prompt, enter the default password password, and
initiate the BOF edit.
The system accepts the password and the following console output is displayed.
You must supply some required Boot Options. At any prompt, you can type: "restart" - restart the query mode. "reboot" - reboot. "exit" - boot with with existing values. "diag" - enter the diag shell. "reset" - reset the bof and reboot. Press ENTER to begin, or 'flash' to enter firmware update...
- At the prompt, press Enter to edit the BOF. The following
console output is displayed.
Chassis-Role ------------- Current chassis-role is : standalone-vc you can change it to { satellite | standalone | factory-default }. Press ENTER to continue OR "edit" to change the chassis-role : standalone Press "edit" to change OR ENTER to continue :
- At the prompt, press Enter. The following output is
displayed.
Chassis-role is set to standalone-vc, Do you wish to continue with this (yes/ no) :
- At the prompt, enter yes. The following console output is
displayed.
VC Stack Node Type -------------------- Current Vc Stack Node type of this card is : imm-only Press ENTER to retain this, or { cpm-imm } to change it to cpm-imm :
- At the prompt, enter cpm-imm. The following output is
displayed.
Setting the Card role to 'cpm-imm'. VC Stack Name ------------- Current VC Stack Name in Bof is : Enter the VC Stack name (max 32 characters) you wish to use : VC123
- At the prompt, enter the name of the VC stack. The following output is
displayed.
Changing the VC Stack Name to VC123 Setting the VC name to 'VC123'. Mac Address of this node is d0:99:d5:9a:6a:41 vc-stack-node field of First cpm-imm Node (cpmA) ------------------------------------------------ You must enter the VC Stack Slot Num that you intend to use and the node's mac address seperated by a space. Example, to use slot-num '1' and mac address 'aa:bb:cc:dd:ee:ff' Type - '1 aa:bb:cc:dd:ee:ff' Accepted VC Stack Slot Num values are - [1 to 8] The existing vc-stack-node and mac field in bof is 'none' vc-stack-node entry of cpmA [1 to 8] [mac address] : 1 d0:99:d5:9a:6a:41
- At the prompt, enter the VC stack slot number and MAC address for CPM-A. The
following output is
displayed.
Using 1 as Vc Stack Slot Id of Node with mac d0:99:d5:9a:6a:41 VC Stack Slot Num of Second cpm-imm Node (cpmB) ----------------------------------------------- You must enter the VC Stack Slot Num that you intend to use. type 'none' if you do not have the details of second cpm-imm node. Accepted VC Stack Slot num values are - [1 to 8] The existing vc-stack-node and mac field in bof is 'none' vc-stack-node entry of cpmB [1 to 8] [mac address] :
- At the prompt, enter the VC stack slot number and MAC address for CPM-B. The
following output is
displayed.
Using 2 as Vc Stack Slot Id of Node with mac d0:99:d5:94:de:41 Software Location ----------------- You must enter the URL of the TiMOS software. The location can be on a Compact Flash device, a USB flash drive, or on the network. Here are some examples cf1:/timos1.0R1 uf1:/timos1.0R1 ftp://user:passwd@192.168.1.150/./timos1.0R1 ftp://user:passwd@[3FFE::1]/./timos1.0R1 or Type 'auto' to retrieve BOF configuration through DHCP. Software Image URL:
- At the prompt, enter the URL location of the software image; for example,
ftp://<user>:<password>@10.10.170.22/./images/both.tim.
The following console output is displayed.
Configuration File Location --------------------------- You must enter the location of configuration file to be used by TiMOS. The file can be on a Compact Flash device, a USB flash drive, or on the network. Here are some examples uf1:/config.cfg cf1:/config.cfg ftp://user:passwd@192.168.1.150/./config.cfg ftp://user:passwd@[3FFE::1]/./config.cfg tftp://192.168.1.150/./config.cfg tftp://[3FFE::1]/./config.cfg Config File URL:
- At the prompt, enter the URL location of the configuration file. The following
console output is displayed.
Network Configuration --------------------- Boot Interface Management ------------------------- You specified a network location for either the software or the configuration file. You need to configure either eth-mgmt or uplinkA or uplinkB ports. You will be asked to configure the port number, IP(v6) address, static routes, and VLAN Id in case of uplink ports. Existing eth-mgmt port settings are: eth-mgmt-port eth-mgmt-address 0 active eth-mgmt-address 0 standby eth-mgmt-address 0 active eth-mgmt-address 0 standby eth-mgmt port is configured for Boot Interface Management, Press ENTER to proceed with existing port settings Or "disable" to disable the port for Boot Interface Management Or "edit" to change the port settings:
- At the prompt, enter edit. The following output is
displayed.
You need to assign an IP address for this port. The IP address should be entered in standard dotted-decimal form with a network length. example: 192.168.1.169/24 Enter eth-mgmt Active IP Address :
- At the prompt, enter the active port IP address and mask that the device should use
(for example, 10.135.4.172/10). The following console output is
displayed.
In case of an IPv6, the IPv6 address should be entered in standard colon hexadecimal notation with a prefix length. example: 3FFE::1/112 Enter eth-mgmt Active IPv6 Address (Type 0 if none desired):
- At the prompt, enter 0. The following console output is
displayed.
Enter eth-mgmt Standby IP Address (Type 0 if none desired):
- At the prompt, enter the standby port IP address and mask that the device should
use. The following output is
displayed.
In case of an IPv6, the IPv6 address should be entered in standard colon hexadecimal notation with a prefix length. example: 3FFE::1/112 Enter eth-mgmt Standby IPv6 Address (Type 0 if none desired):
- At the prompt, enter 0. The following output is
displayed.
You specified network locations which might require static routes to reach. You will be asked to enter static routes until all the locations become reachable. Static routes should be entered in the following format: prefix/mask next-hop ip-address example: 192.168.0.0/16 next-hop 192.168.1.254 Would you like to add a static route? (yes/no)
- At the prompt, enter yes. The following output is
displayed.
Enter ip route:
- At the prompt, enter the static IP route. The following output is
displayed.
OK Would you like to add another static route? (yes/no)
- At the prompt, enter no. The following output is
displayed.
Would you like to add another static IPv6 route? (yes/no)
- At the prompt, enter no. The following console output is
displayed.
Current configuration enables use of console (setting is "no console-disabled") Press ENTER to proceed with existing setting or 'disable' to disable console access :
- At the prompt, press Enter. The following console output is
displayed.
New Settings ------------ primary-image ftp://*:*@10.135.24.85/./img/sass/both.tim primary-config ftp://*:*@10.135.24.85/./cfg/sass/dutE_vcCfg.txt #eth-mgmt Port Settings: no eth-mgmt-disabled eth-mgmt-address 10.135.24.94/24 active eth-mgmt-address 10.135.24.95/24 standby eth-mgmt-route 135.0.0.0/8 next-hop 10.135.24.1 eth-mgmt-autoneg eth-mgmt-duplex full eth-mgmt-speed 100 #System Settings: wait 3 persist off console-speed 115200 no console-disabled vc-stack-name VC123 vc-stack-node-type cpm-imm vc-stack-node cpmA slot-num 1 mac-addr d0:99:d5:9a:6a:41 vc-stack-node cpmB slot-num 2 mac-addr d0:99:d5:94:de:41 Do you want to overwrite cf1:/bof.cfg with the new settings? (yes/no):
- At the prompt, enter yes. The 7210 SAS
device begins to boot with the new settings. The following console output is
displayed.
Successfully saved the new settings in cf1:/bof.cfg ******************* VC Mode ******************** Configuring Network with eth-mgmt Port Setting..... Primary config file location: ftp://*:*@10.135.24.85/./cfg/sass/dutE_vcCfg.txt Initial DNS resolving preference is ipv4-only Downloading 'ftp://*:*@10.135.24.85/./cfg/sass/dutE_vcCfg.txt'...OK Sap Index file location: ftp://*:*@10.135.24.85/./cfg/sass/dutE_vcCfg.sdx Downloading 'ftp://*:*@10.135.24.85/./cfg/sass/dutE_vcCfg.sdx'...OK Primary image location: ftp://*:*@10.135.24.85/./img/sass/both.tim Initial DNS resolving preference is ipv4-only Loading image ftp://*:*@10.135.24.85/./img/sass/both.tim Version B-11.0.S127b, Tue May 7 04:46:24 IST 2019 by sasbuild in /home/sasbuild/ 11.0S/panos/main text:(41482848-->183530192) + data:(7134144-->49884044) Executing TiMOS image at 0x2800000
- After the 7210 SAS
device boots up, the following login prompt is
displayed.
All rights reserved. All use subject to applicable license agreements. Built on Wed Apr 20 14:32:04 IST 2011 by builder in /builder/3.0B5/panos/main Login:
- At the prompt, enter admin for the default username and password, and log into the 7210 SAS device.