esa commands
configure
— esa number
— admin-state keyword
— apply-groups reference
— apply-groups-exclude reference
— description description
— host-port port
— apply-groups reference
— apply-groups-exclude reference
— crc-monitor
— signal-degrade
— multiplier number
— threshold number
— signal-failure
— multiplier number
— threshold number
— window-size number
— vm number
— admin-state keyword
— apply-groups reference
— apply-groups-exclude reference
— cores number
— description description
— host-port reference
— memory number
— vm-type keyword
esa command descriptions
esa [esa-id] number
[esa-id] number
admin-state keyword
Synopsis | Administrative state of the ESA | |
Context | configure esa number admin-state keyword | |
Tree | admin-state | |
Options | ||
Default | disable | |
Introduced | 20.5.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
description description
Synopsis | Text description | |
Context | configure esa number description description | |
Tree | description | |
String length | 1 to 80 | |
Introduced | 20.5.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
host-port [host-port] port
[host-port] port
Synopsis | Ethernet port associated with the ESA | |
Context | configure esa number host-port port | |
Tree | host-port | |
Description | This command configures an Ethernet port associated with the ESA-VM instance. The port ID must be the same as the port ID associated with the ESA context on which the ESA-VM is configured. | |
Notes | This element is part of a list key. | |
Introduced | 20.5.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
crc-monitor
Synopsis | Enter the crc-monitor context | |
Context | configure esa number host-port port crc-monitor | |
Tree | crc-monitor | |
Description | Commands in this context configure ESA cyclic redundancy check (CRC) monitoring. | |
Introduced | 24.10.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
signal-degrade
Synopsis | Enter the signal-degrade context | |
Context | configure esa number host-port port crc-monitor signal-degrade | |
Tree | signal-degrade | |
Description | Commands in this context configure the error rate at which to declare the signal degrade (SD) condition on an Ethernet interface. The value represents M*10E-N, a ratio of errored frames over total frames received over W seconds of the sliding window. The CRC errors on the interface are sampled once per second. A default of 10 seconds is used when no additional window-size is configured. If you omit the multiplier value, the multiplier returns to the default value of 1. Note: Crossing the configured SD threshold raises a log event. | |
Introduced | 24.10.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
multiplier number
Synopsis | SD multiplier | |
Context | configure esa number host-port port crc-monitor signal-degrade multiplier number | |
Tree | multiplier | |
Max. range | 0 to 4294967295 | |
Default | 1 | |
Introduced | 24.10.R1 | |
Platforms |
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
threshold number
Synopsis | SD threshold | |
Context | configure esa number host-port port crc-monitor signal-degrade threshold number | |
Tree | threshold | |
Range | 1 to 9 | |
Introduced | 24.10.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
signal-failure
Synopsis | Enter the signal-failure context | |
Context | configure esa number host-port port crc-monitor signal-failure | |
Tree | signal-failure | |
Description | Commands in this context configure the error rate at which to declare the signal failure (SF) condition on an Ethernet interface. The value represents M*10E-N, errored frames over total frames received over W seconds of the sliding window. The CRC errors on the interface are sampled once per second. A default of 10 seconds is used when no additional window-size is configured. If you omit the multiplier value, the multiplier returns to the default value of 1. Note: Crossing the configured signal failure (SF) threshold causes the router ESA port to enter an operational state of down when the router side detects the SF, or the port is shut down when the ESA detects the SF, which triggers redundancy for all configured ISA groups. | |
Introduced | 24.10.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
multiplier number
Synopsis | SF multiplier | |
Context | configure esa number host-port port crc-monitor signal-failure multiplier number | |
Tree | multiplier | |
Max. range | 0 to 4294967295 | |
Default | 1 | |
Introduced | 24.10.R1 | |
Platforms |
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
threshold number
Synopsis | SF threshold | |
Context | configure esa number host-port port crc-monitor signal-failure threshold number | |
Tree | threshold | |
Range | 1 to 9 | |
Introduced | 24.10.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
window-size number
Synopsis | Window size of the monitor | |
Context | configure esa number host-port port crc-monitor window-size number | |
Tree | window-size | |
Range | 10 to 60 | |
Units | seconds | |
Default | 10 | |
Introduced | 24.10.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
vm [vm-id] number
[vm-id] number
admin-state keyword
Synopsis | Administrative state of the ESA-VM instance | |
Context | configure esa number vm number admin-state keyword | |
Tree | admin-state | |
Description | This command configures the administrative state of the ESA-VM instance. The state affects the operational state of the instance and all entities contained within the instance; however, configuration settings or statistics are not changed, reset, or removed. | |
Options | ||
Default | disable | |
Introduced | 20.5.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
cores number
Warning: Modifying this element toggles the admin-state of the parent element automatically for the new value to take effect. | ||
Synopsis | Number of CPU physical cores allocated to the ESA-VM | |
Context | configure esa number vm number cores number | |
Tree | cores | |
Description | This command specifies the number of CPU physical cores allocated to the ESA-VM instance. If an invalid value is configured for the number of cores, the VM remains in a failed state. | |
Range | 0 to 128 | |
Default | 0 | |
Introduced | 20.5.R1 | |
Platforms |
7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
description description
Synopsis | Text description | |
Context | configure esa number vm number description description | |
Tree | description | |
String length | 1 to 80 | |
Introduced | 20.5.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
host-port reference
Warning: Modifying this element recreates the parent element automatically for the new value to take effect. | ||
Synopsis | Ethernet port associated with the ESA-VM instance | |
Context | configure esa number vm number host-port reference | |
Tree | host-port | |
Description | This command configures an Ethernet port associated with the ESA-VM instance. The port ID must be the same as the port ID associated with the ESA context on which the ESA-VM is configured. | |
Reference | ||
Introduced | 20.5.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |
memory number
Warning: Modifying this element toggles the admin-state of the parent element automatically for the new value to take effect. | ||
Synopsis | Amount of memory allocated to the ESA-VM | |
Context | configure esa number vm number memory number | |
Tree | memory | |
Range | 0 to 256 | |
Units | gigabytes | |
Default | 0 | |
Introduced | 20.5.R1 | |
Platforms | 7450 ESS, 7750 SR, 7750 SR-e, 7750 SR-s |