chassis

alarmInput1StateCleared

Table 1. alarmInput1StateCleared properties

Property name

Value

Application name

chassis

Event name

alarmInput1StateCleared

Default severity

alert

Message format string

Alarm input alarm_input_description has changed status to alarm_clear_message

Cause

The alarmInput1StateCleared event is logged when the status of the alarm 1 input on pin 1 changes.

Effect

An event has occurred in the external equipment connected to the alarm input.

Raising event

alarmInput1StateRaised

Clearing event

N/A

alarmInput1StateRaised

Table 2. alarmInput1StateRaised properties

Property name

Value

Application name

chassis

Event name

alarmInput1StateRaised

Default severity

alert

Message format string

Alarm input alarm_input_description has changed status to alarm_trigger_message

Cause

The alarmInput1StateRaised event is raised when the status of the alarm 1 input on pin 1 changes.

Effect

An event has occurred in the external equipment connected to the alarm input.

Raising event

N/A

Clearing event

alarmInput1StateCleared

alarmInput2StateCleared

Table 3. alarmInput2StateCleared properties

Property name

Value

Application name

chassis

Event name

alarmInput2StateCleared

Default severity

alert

Message format string

Alarm input alarm_input_description has changed status to alarm_clear_message

Cause

The alarmInput2StateCleared event is logged when the status of the alarm 2 input on pin 2 changes.

Effect

An event has occurred in the external equipment connected to the alarm input.

Raising event

alarmInput2StateRaised

Clearing event

N/A

alarmInput2StateRaised

Table 4. alarmInput2StateRaised properties

Property name

Value

Application name

chassis

Event name

alarmInput2StateRaised

Default severity

alert

Message format string

Alarm input alarm_input_description has changed status to alarm_trigger_message

Cause

The alarmInput2StateRaised event is raised when the status of the alarm 2 input on pin 2 changes.

Effect

An event has occurred in the external equipment connected to the alarm input.

Raising event

N/A

Clearing event

alarmInput2StateCleared

alarmInput3StateCleared

Table 5. alarmInput3StateCleared properties

Property name

Value

Application name

chassis

Event name

alarmInput3StateCleared

Default severity

alert

Message format string

Alarm input alarm_input_description has changed status to alarm_clear_message

Cause

The alarmInput3StateCleared event is logged when the status of the alarm 3 input on pin 4 changes.

Effect

An event has occurred in the external equipment connected to the alarm input.

Raising event

alarmInput3StateRaised

Clearing event

N/A

alarmInput3StateRaised

Table 6. alarmInput3StateRaised properties

Property name

Value

Application name

chassis

Event name

alarmInput3StateRaised

Default severity

alert

Message format string

Alarm input alarm_input_description has changed status to alarm_trigger_message

Cause

The alarmInput3StateRaised event is raised when the status of the alarm 3 input on pin 4 changes.

Effect

An event has occurred in the external equipment connected to the alarm input.

Raising event

N/A

Clearing event

alarmInput3StateCleared

alarmInput4StateCleared

Table 7. alarmInput4StateCleared properties

Property name

Value

Application name

chassis

Event name

alarmInput4StateCleared

Default severity

alert

Message format string

Alarm input alarm_input_description has changed status to alarm_clear_message

Cause

The alarmInput4StateCleared event is logged when the status of the alarm 4 input on pin 5 changes.

Effect

An event has occurred in the external equipment connected to the alarm input.

Raising event

alarmInput4StateRaised

Clearing event

N/A

alarmInput4StateRaised

Table 8. alarmInput4StateRaised properties

Property name

Value

Application name

chassis

Event name

alarmInput4StateRaised

Default severity

alert

Message format string

Alarm input alarm_input_description has changed status to alarm_trigger_message

Cause

The alarmInput4StateRaised event is raised when the status of the alarm 4 input on pin 5 changes.

Effect

An event has occurred in the external equipment connected to the alarm input.

Raising event

N/A

Clearing event

alarmInput4StateCleared

interfaceStormControlRateReached

Table 9. interfaceStormControlRateReached properties

Property name

Value

Application name

chassis

Event name

interfaceStormControlRateReached

Default severity

warning

Message format string

The ingress traffic rate in interface-name has exceeded at least one of the configured storm-control rates (broadcast, multicast or unknown-unicast rates).

Cause

This event is generated when the traffic exceeds any of the configured storm control rates.

Effect

broadcast, multicast or unknown-unicast frames are discarded at this rate

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighGainAlarm

Table 10. olsTransceiverAmplifierHighGainAlarm properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighGainAlarm

Default severity

error

Message format string

The gain of the amplifier_name of the optical line system in interface interface_name has increased to high_threshold dBm or above

Cause

The gain of the amplifier in the module has increased

Effect

High gain may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighGainAlarmClear

Table 11. olsTransceiverAmplifierHighGainAlarmClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighGainAlarmClear

Default severity

informational

Message format string

The gain of the amplifier_name of the optical line system in interface interface_name decreased below high_threshold dBm

Cause

The gain of the amplifier in the module has decreased

Effect

High gain may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighGainWarning

Table 12. olsTransceiverAmplifierHighGainWarning properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighGainWarning

Default severity

warning

Message format string

The gain of the amplifier_name of the optical line system in interface interface_name has increased to high_threshold dBm or above

Cause

The gain of the amplifier in the module has increased

Effect

High gain may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighGainWarningClear

Table 13. olsTransceiverAmplifierHighGainWarningClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighGainWarningClear

Default severity

informational

Message format string

The gain of the amplifier_name of the optical line system in interface interface_name decreased below high_threshold dBm

Cause

The gain of the amplifier in the module has decreased

Effect

High gain may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighInputPowerAlarm

Table 14. olsTransceiverAmplifierHighInputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighInputPowerAlarm

Default severity

error

Message format string

The input power of the amplifier_name of the optical line system in interface interface_name has increased to high_threshold dBm or above

Cause

The input power of the amplifier in the module has increased

Effect

High input power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighInputPowerAlarmClear

Table 15. olsTransceiverAmplifierHighInputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighInputPowerAlarmClear

Default severity

informational

Message format string

The input power of the amplifier_name of the optical line system in interface interface_name decreased below high_threshold dBm

Cause

The input power of the amplifier in the module has decreased

Effect

High input power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighInputPowerWarning

Table 16. olsTransceiverAmplifierHighInputPowerWarning properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighInputPowerWarning

Default severity

warning

Message format string

The input power of the amplifier_name of the optical line system in interface interface_name has increased to high_threshold dBm or above

Cause

The input power of the amplifier in the module has increased

Effect

High input power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighInputPowerWarningClear

Table 17. olsTransceiverAmplifierHighInputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighInputPowerWarningClear

Default severity

informational

Message format string

The input power of the amplifier_name of the optical line system in interface interface_name decreased below high_threshold dBm

Cause

The input power of the amplifier in the module has decreased

Effect

High input power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighOutputPowerAlarm

Table 18. olsTransceiverAmplifierHighOutputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighOutputPowerAlarm

Default severity

error

Message format string

The output power of the amplifier_name of the optical line system in interface interface_name has increased to high_threshold dBm or above

Cause

The output power of the amplifier in the module has increased

Effect

High output power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighOutputPowerAlarmClear

Table 19. olsTransceiverAmplifierHighOutputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighOutputPowerAlarmClear

Default severity

informational

Message format string

The output power of the amplifier_name of the optical line system in interface interface_name decreased below high_threshold dBm

Cause

The output power of the amplifier in the module has decreased

Effect

High output power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighOutputPowerWarning

Table 20. olsTransceiverAmplifierHighOutputPowerWarning properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighOutputPowerWarning

Default severity

warning

Message format string

The output power of the amplifier_name of the optical line system in interface interface_name has increased to high_threshold dBm or above

Cause

The output power of the amplifier in the module has increased

Effect

High output power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighOutputPowerWarningClear

Table 21. olsTransceiverAmplifierHighOutputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighOutputPowerWarningClear

Default severity

informational

Message format string

The output power of the amplifier_name of the optical line system in interface interface_name decreased below high_threshold dBm

Cause

The output power of the amplifier in the module has decreased

Effect

High output power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighTempAlarm

Table 22. olsTransceiverAmplifierHighTempAlarm properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighTempAlarm

Default severity

error

Message format string

The temperature of the amplifier_name of the optical line system in interface interface_name has increased to high_threshold degrees C or above

Cause

The temperature of the amplifier in the module has increased

Effect

High temperatures may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighTempAlarmClear

Table 23. olsTransceiverAmplifierHighTempAlarmClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighTempAlarmClear

Default severity

informational

Message format string

The temperature of the amplifier_name of the optical line system in interface interface_name decreased below high_threshold degrees C

Cause

The temperature of the amplifier in the module has decreased

Effect

High temperatures may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighTempWarning

Table 24. olsTransceiverAmplifierHighTempWarning properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighTempWarning

Default severity

warning

Message format string

The temperature of the amplifier_name of the optical line system in interface interface_name has increased to high_threshold degrees C or above

Cause

The temperature of the amplifier in the module has increased

Effect

High temperatures may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierHighTempWarningClear

Table 25. olsTransceiverAmplifierHighTempWarningClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierHighTempWarningClear

Default severity

informational

Message format string

The temperature of the amplifier_name of the optical line system in interface interface_name decreased below high_threshold degrees C

Cause

The temperature of the amplifier in the module has decreased

Effect

High temperatures may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowGainAlarm

Table 26. olsTransceiverAmplifierLowGainAlarm properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowGainAlarm

Default severity

error

Message format string

The gain of the amplifier_name of the optical line system in interface interface_name has decreased to low_threshold dBm or below

Cause

The gain of the amplifier in the module has decreased

Effect

Low gain may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowGainAlarmClear

Table 27. olsTransceiverAmplifierLowGainAlarmClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowGainAlarmClear

Default severity

informational

Message format string

The gain of the amplifier_name of the optical line system in interface interface_name has increased to low_threshold dBm or above

Cause

The gain of the amplifier in the module has increased

Effect

Low gain may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowGainWarning

Table 28. olsTransceiverAmplifierLowGainWarning properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowGainWarning

Default severity

warning

Message format string

The gain of the amplifier_name of the optical line system in interface interface_name has decreased to low_threshold dBm or below

Cause

The gain of the amplifier in the module has decreased

Effect

Low gain may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowGainWarningClear

Table 29. olsTransceiverAmplifierLowGainWarningClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowGainWarningClear

Default severity

informational

Message format string

The gain of the amplifier_name of the optical line system in interface interface_name has increased to low_threshold dBm or above

Cause

The gain of the amplifier in the module has increased

Effect

Low gain may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowInputPowerAlarm

Table 30. olsTransceiverAmplifierLowInputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowInputPowerAlarm

Default severity

error

Message format string

The input power of the amplifier_name of the optical line system in interface interface_name has decreased to low_threshold dBm or below

Cause

The input power of the amplifier in the module has decreased

Effect

Low input power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowInputPowerAlarmClear

Table 31. olsTransceiverAmplifierLowInputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowInputPowerAlarmClear

Default severity

informational

Message format string

The input power of the amplifier_name of the optical line system in interface interface_name has increased to low_threshold dBm or above

Cause

The input power of the amplifier in the module has increased

Effect

Low input power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowInputPowerWarning

Table 32. olsTransceiverAmplifierLowInputPowerWarning properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowInputPowerWarning

Default severity

warning

Message format string

The input power of the amplifier_name of the optical line system in interface interface_name has decreased to low_threshold dBm or below

Cause

The input power of the amplifier in the module has decreased

Effect

Low input power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowInputPowerWarningClear

Table 33. olsTransceiverAmplifierLowInputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowInputPowerWarningClear

Default severity

informational

Message format string

The input power of the amplifier_name of the optical line system in interface interface_name has increased to low_threshold dBm or above

Cause

The input power of the amplifier in the module has increased

Effect

Low input power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowOutputPowerAlarm

Table 34. olsTransceiverAmplifierLowOutputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowOutputPowerAlarm

Default severity

error

Message format string

The output power of the amplifier_name of the optical line system in interface interface_name has decreased to low_threshold dBm or below

Cause

The output power of the amplifier in the module has decreased

Effect

Low output power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowOutputPowerAlarmClear

Table 35. olsTransceiverAmplifierLowOutputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowOutputPowerAlarmClear

Default severity

informational

Message format string

The output power of the amplifier_name of the optical line system in interface interface_name has increased to low_threshold dBm or above

Cause

The output power of the amplifier in the module has increased

Effect

Low output power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowOutputPowerWarning

Table 36. olsTransceiverAmplifierLowOutputPowerWarning properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowOutputPowerWarning

Default severity

warning

Message format string

The output power of the amplifier_name of the optical line system in interface interface_name has decreased to low_threshold dBm or below

Cause

The output power of the amplifier in the module has decreased

Effect

Low output power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowOutputPowerWarningClear

Table 37. olsTransceiverAmplifierLowOutputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowOutputPowerWarningClear

Default severity

informational

Message format string

The output power of the amplifier_name of the optical line system in interface interface_name has increased to low_threshold dBm or above

Cause

The output power of the amplifier in the module has increased

Effect

Low output power may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowTempAlarm

Table 38. olsTransceiverAmplifierLowTempAlarm properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowTempAlarm

Default severity

error

Message format string

The temperature of the amplifier_name of the optical line system in interface interface_name has decreased to low_threshold degrees C or below

Cause

The temperature of the amplifier in the module has decreased

Effect

Low temperatures may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowTempAlarmClear

Table 39. olsTransceiverAmplifierLowTempAlarmClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowTempAlarmClear

Default severity

informational

Message format string

The temperature of the amplifier_name of the optical line system in interface interface_name has increased to low_threshold degrees C or above

Cause

The temperature of the amplifier in the module has increased

Effect

Low temperatures may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowTempWarning

Table 40. olsTransceiverAmplifierLowTempWarning properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowTempWarning

Default severity

warning

Message format string

The temperature of the amplifier_name of the optical line system in interface interface_name has decreased to low_threshold degrees C or below

Cause

The temperature of the amplifier in the module has decreased

Effect

Low temperatures may affect module performance

Raising event

N/A

Clearing event

N/A

olsTransceiverAmplifierLowTempWarningClear

Table 41. olsTransceiverAmplifierLowTempWarningClear properties

Property name

Value

Application name

chassis

Event name

olsTransceiverAmplifierLowTempWarningClear

Default severity

informational

Message format string

The temperature of the amplifier_name of the optical line system in interface interface_name has increased to low_threshold degrees C or above

Cause

The temperature of the amplifier in the module has increased

Effect

Low temperatures may affect module performance

Raising event

N/A

Clearing event

N/A

platformDatapathResourceHighUtilization

Table 42. platformDatapathResourceHighUtilization properties

Property name

Value

Application name

chassis

Event name

platformDatapathResourceHighUtilization

Default severity

warning

Message format string

The datapath resource called resource-name has reached threshold% or more utilization on linecard linecard, forwarding complex forwarding-complex

Cause

This event is generated when the utilization of a datapath resource has increased to a level that may warrant concern if further resources are consumed

Effect

None

Raising event

N/A

Clearing event

N/A

platformDatapathResourceHighUtilizationLowered

Table 43. platformDatapathResourceHighUtilizationLowered properties

Property name

Value

Application name

chassis

Event name

platformDatapathResourceHighUtilizationLowered

Default severity

notice

Message format string

The datapath resource called resource-name has decreased back to threshold% or less utilization on linecard linecard, forwarding complex forwarding-complex

Cause

This event is generated when the utilization of a datapath resource has decreased to a level that may no longer warrant concern

Effect

None

Raising event

N/A

Clearing event

N/A

platformDatapathResourceLimitCleared

Table 44. platformDatapathResourceLimitCleared properties

Property name

Value

Application name

chassis

Event name

platformDatapathResourceLimitCleared

Default severity

notice

Message format string

The datapath resource called resource-name has decreased from 100% utilization back to 95% or less utilization on linecard linecard, forwarding complex forwarding-complex

Cause

This event is generated when the utilization of a datapath resource has decreased to a level such that resource exhaustion is no longer imminent

Effect

None

Raising event

N/A

Clearing event

N/A

platformDatapathResourceLimitReached

Table 45. platformDatapathResourceLimitReached properties

Property name

Value

Application name

chassis

Event name

platformDatapathResourceLimitReached

Default severity

warning

Message format string

The datapath resource called resource-name has reached 100% utilization on linecard linecard, forwarding complex forwarding-complex

Cause

This event is generated when the utilization of a datapath resource has exhausted the resource

Effect

None

Raising event

N/A

Clearing event

N/A

platformMtuHighUtilization

Table 46. platformMtuHighUtilization properties

Property name

Value

Application name

chassis

Event name

platformMtuHighUtilization

Default severity

warning

Message format string

The MTU resource called resource-name has reached threshold% or more utilization on linecard linecard, forwarding complex forwarding-complex. Only free-entries entries are remaining.

Cause

This event is generated when the utilization of an MTU resource has increased to a level that may warrant concern if further resources are consumed

Effect

None

Raising event

N/A

Clearing event

N/A

platformMtuHighUtilizationLowered

Table 47. platformMtuHighUtilizationLowered properties

Property name

Value

Application name

chassis

Event name

platformMtuHighUtilizationLowered

Default severity

notice

Message format string

The MTU resource called resource-name has decreased back to threshold% or less utilization on linecard linecard, forwarding complex forwarding-complex.

Cause

This event is generated when the utilization of an MTU resource has decreased to a level that may no longer warrant concern

Effect

None

Raising event

N/A

Clearing event

N/A

platformPipelineResourceHighUtilization

Table 48. platformPipelineResourceHighUtilization properties

Property name

Value

Application name

chassis

Event name

platformPipelineResourceHighUtilization

Default severity

warning

Message format string

The pipeline resource called resource-name has reached threshold% or more utilization on linecard linecard, forwarding complex forwarding-complex, pipeline pipeline

Cause

This event is generated when the utilization of a pipeline resource has increased to a level that may warrant concern if futher resources are consumed

Effect

None

Raising event

N/A

Clearing event

N/A

platformPipelineResourceHighUtilizationLowered

Table 49. platformPipelineResourceHighUtilizationLowered properties

Property name

Value

Application name

chassis

Event name

platformPipelineResourceHighUtilizationLowered

Default severity

notice

Message format string

The pipeline resource called resource-name has decreased back to threshold% or less utilization on linecard linecard, forwarding complex forwarding-complex, pipeline pipeline

Cause

This event is generated when the utilization of a pipeline resource has decreased to a level that may no longer warrant concern

Effect

None

Raising event

N/A

Clearing event

N/A

platformPipelineResourceLimitCleared

Table 50. platformPipelineResourceLimitCleared properties

Property name

Value

Application name

chassis

Event name

platformPipelineResourceLimitCleared

Default severity

notice

Message format string

The pipeline resource called resource-name has decreased from 100% utilization back to 95% or less utilization on linecard linecard, forwarding complex forwarding-complex, pipeline

Cause

This event is generated when the utilization of a pipeline resource has decreased to a level such that resource exhaustion is no longer imminent

Effect

None

Raising event

N/A

Clearing event

N/A

platformPipelineResourceLimitReached

Table 51. platformPipelineResourceLimitReached properties

Property name

Value

Application name

chassis

Event name

platformPipelineResourceLimitReached

Default severity

warning

Message format string

The pipeline resource called resource-name has reached 100% utilization on linecard linecard, forwarding complex forwarding-complex, pipeline

Cause

This event is generated when the utilization of a pipeline resource has exhausted the resource

Effect

None

Raising event

N/A

Clearing event

N/A

portDown

Table 52. portDown properties

Property name

Value

Application name

chassis

Event name

portDown

Default severity

warning

Message format string

Interface interface_name is now down for reason: oper_down_reason

Cause

The interface has transitioned from the up state to the down state

Effect

The interface is now down

Raising event

N/A

Clearing event

portUp

portEtherCrcMonAlarmClear

Table 53. portEtherCrcMonAlarmClear properties

Property name

Value

Application name

chassis

Event name

portEtherCrcMonAlarmClear

Default severity

warning

Message format string

Interface interface-name reported CRC frame errors have dropped below configured threshold-name threshold multiplier*10e-exponent

Cause

This event is generated when an Ethernet port CRC monitoring alarm condition is cleared or the monitoring is disabled.

Effect

None

Raising event

N/A

Clearing event

N/A

portEtherCrcMonAlarmSet

Table 54. portEtherCrcMonAlarmSet properties

Property name

Value

Application name

chassis

Event name

portEtherCrcMonAlarmSet

Default severity

warning

Message format string

Interface interface-name reported CRC frame errors in excess of the configured threshold-name threshold multiplier*10e-exponent

Cause

This event is generated when an Ethernet port CRC frame monitoring alarm condition is detected. It is generated only when CRC monitoring is enabled on the port

Effect

On a signal failure (SF) threshold being exceeded, the port is taken out of service until the CRC alarm condition is cleared

Raising event

N/A

Clearing event

N/A

portEtherSymMonAlarmClear

Table 55. portEtherSymMonAlarmClear properties

Property name

Value

Application name

chassis

Event name

portEtherSymMonAlarmClear

Default severity

warning

Message format string

Interface interface-name reported symbol errors have dropped below configured threshold-name threshold multiplier*10e-exponent

Cause

This event is generated when an Ethernet port symbol monitoring alarm condition is cleared or the monitoring is disabled.

Effect

None

Raising event

N/A

Clearing event

N/A

portEtherSymMonAlarmSet

Table 56. portEtherSymMonAlarmSet properties

Property name

Value

Application name

chassis

Event name

portEtherSymMonAlarmSet

Default severity

warning

Message format string

Interface interface-name reported symbol errors in excess of the configured threshold-name threshold multiplier*10e-exponent

Cause

This event is generated when an Ethernet port symbol monitoring alarm condition is detected. It is generated only when symbol monitoring is enabled on the port

Effect

On a signal failure (SF) threshold being exceeded, the port is taken out of service until the symbol alarm condition is cleared

Raising event

N/A

Clearing event

N/A

portUp

Table 57. portUp properties

Property name

Value

Application name

chassis

Event name

portUp

Default severity

notice

Message format string

Interface interface_name is now up

Cause

The interface has transitioned from the down state to the up state

Effect

The interface is now up

Raising event

portDown

Clearing event

N/A

secureBootDisabled

Table 58. secureBootDisabled properties

Property name

Value

Application name

chassis

Event name

secureBootDisabled

Default severity

warning

Message format string

Control module control booted with Secure Boot Disabled

Cause

The control module booted with Secure Boot disabled

Effect

Boot software is not subject to signature verification

Raising event

N/A

Clearing event

secureBootEnabled

secureBootEnabled

Table 59. secureBootEnabled properties

Property name

Value

Application name

chassis

Event name

secureBootEnabled

Default severity

notice

Message format string

Control module control booted with Secure Boot Enabled

Cause

The control module booted with Secure Boot Enabled

Effect

Boot software is subject to signature verification

Raising event

secureBootDisabled

Clearing event

N/A

secureBootModDatasetInconsistent

Table 60. secureBootModDatasetInconsistent properties

Property name

Value

Application name

chassis

Event name

secureBootModDatasetInconsistent

Default severity

warning

Message format string

Control module control secure boot variable modification dataset is not consistent

Cause

The control module booted with Secure Boot enabled, but the secure boot variable modification dataset is not consistent with the secure boot variables

Effect

Boot software was/is subject to complete signature verification, but no update to the variables is possible

Raising event

N/A

Clearing event

N/A

secureBootModDatasetNotPresent

Table 61. secureBootModDatasetNotPresent properties

Property name

Value

Application name

chassis

Event name

secureBootModDatasetNotPresent

Default severity

warning

Message format string

Control module control secure boot variable modification dataset in not present

Cause

The control module booted with Secure Boot enabled, but the secure boot variable modification dataset is not present

Effect

Boot software was/is subject to complete signature verification, but no update to the variables is possible

Raising event

N/A

Clearing event

N/A

secureBootRevokeUpdateRecommended

Table 62. secureBootRevokeUpdateRecommended properties

Property name

Value

Application name

chassis

Event name

secureBootRevokeUpdateRecommended

Default severity

alert

Message format string

Control module control secure boot database revoke list (dbx) is inconsistent

Cause

The control module booted with Secure Boot enabled, but the secure boot database dbx contents are inconsistent with the expected values from the variable modification data set

Effect

Boot software was/is not subject to complete signature verification against the dbx (revoke list)

Raising event

N/A

Clearing event

N/A

secureBootVariablesConsistent

Table 63. secureBootVariablesConsistent properties

Property name

Value

Application name

chassis

Event name

secureBootVariablesConsistent

Default severity

notice

Message format string

Control module control secure boot variables are consistent

Cause

The control module booted with Secure Boot enabled, and the secure boot variables are consistent with the expected values from the variable modification data set

Effect

Boot software was/is subject to complete signature verification

Raising event

N/A

Clearing event

N/A

secureBootVarsUpdateRecommended

Table 64. secureBootVarsUpdateRecommended properties

Property name

Value

Application name

chassis

Event name

secureBootVarsUpdateRecommended

Default severity

warning

Message format string

Control module control secure boot database update recommended

Cause

The control module booted with Secure Boot enabled, but the secure boot database contents are inconsistent with the expected values from the variable modification data set

Effect

Current software was subject to complete signature verification, however an update to the secure boot database is recommended

Raising event

N/A

Clearing event

N/A

subinterfaceDown

Table 65. subinterfaceDown properties

Property name

Value

Application name

chassis

Event name

subinterfaceDown

Default severity

warning

Message format string

The subinterface subinterface_name is now down for reason: oper_down_reason

Cause

This event is generated when the subinterface has transitioned from the up state to the down state

Effect

The subinterface is now down

Raising event

N/A

Clearing event

N/A

subinterfaceUp

Table 66. subinterfaceUp properties

Property name

Value

Application name

chassis

Event name

subinterfaceUp

Default severity

notice

Message format string

The subinterface subinterface_name is now up

Cause

This event is generated when the subinterface has transitioned from the down state to the up state.

Effect

The subinterface is now up

Raising event

N/A

Clearing event

N/A

systemResourceHighUtilization

Table 67. systemResourceHighUtilization properties

Property name

Value

Application name

chassis

Event name

systemResourceHighUtilization

Default severity

warning

Message format string

The system resource called resource-name has reached threshold% or more utilization

Cause

This event is generated when the utilization of a system resource has increased to a level that may warrant concern if further resources are consumed

Effect

None

Raising event

N/A

Clearing event

N/A

systemResourceHighUtilizationLowered

Table 68. systemResourceHighUtilizationLowered properties

Property name

Value

Application name

chassis

Event name

systemResourceHighUtilizationLowered

Default severity

notice

Message format string

The system resource called resource-name has decreased back to threshold% or less utilization

Cause

This event is generated when the utilization of a system resource has decreased to a level that may no longer warrant concern

Effect

None

Raising event

N/A

Clearing event

N/A

systemResourceLimitCleared

Table 69. systemResourceLimitCleared properties

Property name

Value

Application name

chassis

Event name

systemResourceLimitCleared

Default severity

notice

Message format string

The system resource called resource-name has decreased from 100% utilization back to 95% or less utilization

Cause

This event is generated when the utilization of a system resource has decreased to a level such that resource exhaustion is no longer imminent

Effect

None

Raising event

N/A

Clearing event

N/A

systemResourceLimitReached

Table 70. systemResourceLimitReached properties

Property name

Value

Application name

chassis

Event name

systemResourceLimitReached

Default severity

warning

Message format string

The system resource called resource-name has reached 100% utilization

Cause

This event is generated when the utilization of a system resource has exhausted the resource

Effect

None

Raising event

N/A

Clearing event

N/A

transceiverChannelHighInputPowerAlarm

Table 71. transceiverChannelHighInputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighInputPowerAlarm

Default severity

critical

Message format string

The input power measured for channel channel_num of the transceiver associated with interface interface_name has increased to high_threshold dBm or more

Cause

The input power of the optical channel has increased

Effect

High input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighInputPowerAlarmClear

Table 72. transceiverChannelHighInputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighInputPowerAlarmClear

Default severity

informational

Message format string

The input power measured for channel channel_num of the transceiver associated with interface interface_name has decreased below high_threshold dBm

Cause

The input power of the optical channel has decreased

Effect

High input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighInputPowerWarning

Table 73. transceiverChannelHighInputPowerWarning properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighInputPowerWarning

Default severity

warning

Message format string

The input power measured for channel channel_num of the transceiver associated with interface interface_name has increased to high_threshold dBm or more

Cause

The input power of the optical channel has increased

Effect

High input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighInputPowerWarningClear

Table 74. transceiverChannelHighInputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighInputPowerWarningClear

Default severity

informational

Message format string

The input power measured for channel channel_num of the transceiver associated with interface interface_name has decreased below high_threshold dBm

Cause

The input power of the optical channel has decreased

Effect

High input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighLaserBiasCurrentAlarm

Table 75. transceiverChannelHighLaserBiasCurrentAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighLaserBiasCurrentAlarm

Default severity

critical

Message format string

The laser bias current supplied to channel channel_num of the transceiver associated with interface interface_name has increased to high_threshold mA or more

Cause

Laser bias increases with temperature and age. Consider lowering the ambient temperature or replacing the laser.

Effect

High laser bias may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighLaserBiasCurrentAlarmClear

Table 76. transceiverChannelHighLaserBiasCurrentAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighLaserBiasCurrentAlarmClear

Default severity

informational

Message format string

The laser bias current supplied to channel channel_num of the transceiver associated with interface interface_name has decreased below high_threshold mA

Cause

Laser bias current has decreased

Effect

High laser bias may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighLaserBiasCurrentWarning

Table 77. transceiverChannelHighLaserBiasCurrentWarning properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighLaserBiasCurrentWarning

Default severity

warning

Message format string

The laser bias current supplied to channel channel_num of the transceiver associated with interface interface_name has increased to high_threshold mA or more

Cause

Laser bias increases with temperature and age. Consider lowering the ambient temperature or replacing the laser.

Effect

High laser bias may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighLaserBiasCurrentWarningClear

Table 78. transceiverChannelHighLaserBiasCurrentWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighLaserBiasCurrentWarningClear

Default severity

informational

Message format string

The laser bias current supplied to channel channel_num of the transceiver associated with interface interface_name has decreased below high_threshold mA

Cause

Laser bias current has decreased

Effect

High laser bias may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighOutputPowerAlarm

Table 79. transceiverChannelHighOutputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighOutputPowerAlarm

Default severity

critical

Message format string

The output power measured for channel channel_num of the transceiver associated with interface interface_name has increased to high_threshold dBm or more

Cause

The output power of the optical channel has increased

Effect

High output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighOutputPowerAlarmClear

Table 80. transceiverChannelHighOutputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighOutputPowerAlarmClear

Default severity

informational

Message format string

The output power measured for channel channel_num of the transceiver associated with interface interface_name has decreased below high_threshold dBm

Cause

The output power of the optical channel has decreased

Effect

High output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighOutputPowerWarning

Table 81. transceiverChannelHighOutputPowerWarning properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighOutputPowerWarning

Default severity

warning

Message format string

The output power measured for channel channel_num of the transceiver associated with interface interface_name has increased to high_threshold dBm or more

Cause

The output power of the optical channel has increased

Effect

High output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelHighOutputPowerWarningClear

Table 82. transceiverChannelHighOutputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelHighOutputPowerWarningClear

Default severity

informational

Message format string

The output power measured for channel channel_num of the transceiver associated with interface interface_name has decreased below high_threshold dBm

Cause

The output power of the optical channel has decreased

Effect

High output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowInputPowerAlarm

Table 83. transceiverChannelLowInputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowInputPowerAlarm

Default severity

critical

Message format string

The input power measured for channel channel_num of the transceiver associated with interface interface_name has decreased to low_threshold dBm or less

Cause

The input power of the optical channel has decreased

Effect

Low input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowInputPowerAlarmClear

Table 84. transceiverChannelLowInputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowInputPowerAlarmClear

Default severity

informational

Message format string

The input power measured for channel channel_num of the transceiver associated with interface interface_name has increased above low_threshold dBm

Cause

The input power of the optical channel has increased

Effect

Low input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowInputPowerWarning

Table 85. transceiverChannelLowInputPowerWarning properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowInputPowerWarning

Default severity

warning

Message format string

The input power measured for channel channel_num of the transceiver associated with interface interface_name has decreased to low_threshold dBm or less

Cause

The input power of the optical channel has decreased

Effect

Low input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowInputPowerWarningClear

Table 86. transceiverChannelLowInputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowInputPowerWarningClear

Default severity

informational

Message format string

The input power measured for channel channel_num of the transceiver associated with interface interface_name has increased above low_threshold dBm

Cause

The input power of the optical channel has increased

Effect

Low input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowLaserBiasCurrentAlarm

Table 87. transceiverChannelLowLaserBiasCurrentAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowLaserBiasCurrentAlarm

Default severity

critical

Message format string

The laser bias current supplied to channel channel_num of the transceiver associated with interface interface_name has decreased to low_threshold mA or less

Cause

The laser bias current of the optical channel has decreased

Effect

Low laser bias current may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowLaserBiasCurrentAlarmClear

Table 88. transceiverChannelLowLaserBiasCurrentAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowLaserBiasCurrentAlarmClear

Default severity

informational

Message format string

The laser bias current supplied to channel channel_num of the transceiver associated with interface interface_name has increased above low_threshold mA

Cause

The laser bias current of the optical channel has increased

Effect

Low laser bias current may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowLaserBiasCurrentWarning

Table 89. transceiverChannelLowLaserBiasCurrentWarning properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowLaserBiasCurrentWarning

Default severity

warning

Message format string

The laser bias current supplied to channel channel_num of the transceiver associated with interface interface_name has decreased to low_threshold mA or less

Cause

The laser bias current of the optical channel has decreased

Effect

Low laser bias current may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowLaserBiasCurrentWarningClear

Table 90. transceiverChannelLowLaserBiasCurrentWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowLaserBiasCurrentWarningClear

Default severity

informational

Message format string

The laser bias current supplied to channel channel_num of the transceiver associated with interface interface_name has increased above low_threshold mA

Cause

The laser bias current of the optical channel has increased

Effect

Low laser bias current may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowOutputPowerAlarm

Table 91. transceiverChannelLowOutputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowOutputPowerAlarm

Default severity

critical

Message format string

The output power measured for channel channel_num of the transceiver associated with interface interface_name has decreased to low_threshold dBm or less

Cause

The output power of the optical channel has decreased

Effect

Low output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowOutputPowerAlarmClear

Table 92. transceiverChannelLowOutputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowOutputPowerAlarmClear

Default severity

informational

Message format string

The output power measured for channel channel_num of the transceiver associated with interface interface_name has increased above low_threshold dBm

Cause

The output power of the optical channel has increased

Effect

Low output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowOutputPowerWarning

Table 93. transceiverChannelLowOutputPowerWarning properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowOutputPowerWarning

Default severity

warning

Message format string

The output power measured for channel channel_num of the transceiver associated with interface interface_name has decreased to low_threshold dBm or less

Cause

The output power of the optical channel has decreased

Effect

Low output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverChannelLowOutputPowerWarningClear

Table 94. transceiverChannelLowOutputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverChannelLowOutputPowerWarningClear

Default severity

informational

Message format string

The output power measured for channel channel_num of the transceiver associated with interface interface_name has increased above low_threshold dBm

Cause

The output power of the optical channel has increased

Effect

Low output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighInputPowerAlarm

Table 95. transceiverHighInputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverHighInputPowerAlarm

Default severity

critical

Message format string

The input power measured for the transceiver associated with interface interface_name has increased to high_threshold dBm or more

Cause

The input power of the optics has increased

Effect

High input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighInputPowerAlarmClear

Table 96. transceiverHighInputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverHighInputPowerAlarmClear

Default severity

informational

Message format string

The input power measured for the transceiver associated with interface interface_name has decreased below high_threshold dBm

Cause

The input power of the optics has decreased

Effect

High input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighInputPowerWarning

Table 97. transceiverHighInputPowerWarning properties

Property name

Value

Application name

chassis

Event name

transceiverHighInputPowerWarning

Default severity

warning

Message format string

The input power measured for the transceiver associated with interface interface_name has increased to high_threshold dBm or more

Cause

The input power of the optics has increased

Effect

High input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighInputPowerWarningClear

Table 98. transceiverHighInputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverHighInputPowerWarningClear

Default severity

informational

Message format string

The input power measured for the transceiver associated with interface interface_name has decreased below high_threshold dBm

Cause

The input power of the opticsl has decreased

Effect

High input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighLaserBiasCurrentAlarm

Table 99. transceiverHighLaserBiasCurrentAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverHighLaserBiasCurrentAlarm

Default severity

critical

Message format string

The laser bias current supplied to the transceiver associated with interface interface_name has increased to high_threshold mA or more

Cause

Laser bias increases with temperature and age. Consider lowering the ambient temperature or replacing the laser.

Effect

High laser bias may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighLaserBiasCurrentAlarmClear

Table 100. transceiverHighLaserBiasCurrentAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverHighLaserBiasCurrentAlarmClear

Default severity

informational

Message format string

The laser bias current supplied to the transceiver associated with interface interface_name has decreased below high_threshold mA

Cause

Laser bias current has decreased

Effect

High laser bias may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighLaserBiasCurrentWarning

Table 101. transceiverHighLaserBiasCurrentWarning properties

Property name

Value

Application name

chassis

Event name

transceiverHighLaserBiasCurrentWarning

Default severity

warning

Message format string

The laser bias current supplied to the transceiver associated with interface interface_name has increased to high_threshold mA or more

Cause

Laser bias increases with temperature and age. Consider lowering the ambient temperature or replacing the laser.

Effect

High laser bias may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighLaserBiasCurrentWarningClear

Table 102. transceiverHighLaserBiasCurrentWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverHighLaserBiasCurrentWarningClear

Default severity

informational

Message format string

The laser bias current supplied to the transceiver associated with interface interface_name has decreased below high_threshold mA

Cause

Laser bias current has decreased

Effect

High laser bias may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighOutputPowerAlarm

Table 103. transceiverHighOutputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverHighOutputPowerAlarm

Default severity

critical

Message format string

The output power measured for the transceiver associated with interface interface_name has increased to high_threshold dBm or more

Cause

The output power of the optics has increased

Effect

High output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighOutputPowerAlarmClear

Table 104. transceiverHighOutputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverHighOutputPowerAlarmClear

Default severity

informational

Message format string

The output power measured for the transceiver associated with interface interface_name has decreased below high_threshold dBm

Cause

The output power of the optics has decreased

Effect

High output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighOutputPowerWarning

Table 105. transceiverHighOutputPowerWarning properties

Property name

Value

Application name

chassis

Event name

transceiverHighOutputPowerWarning

Default severity

warning

Message format string

The output power measured for the transceiver associated with interface interface_name has increased to high_threshold dBm or more

Cause

The output power of the optics has increased

Effect

High output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverHighOutputPowerWarningClear

Table 106. transceiverHighOutputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverHighOutputPowerWarningClear

Default severity

informational

Message format string

The output power measured for the transceiver associated with interface interface_name has decreased below high_threshold dBm

Cause

The output power of the optics has decreased

Effect

High output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowInputPowerAlarm

Table 107. transceiverLowInputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverLowInputPowerAlarm

Default severity

critical

Message format string

The input power measured for the transceiver associated with interface interface_name has decreased to low_threshold dBm or less

Cause

The input power of the optics has decreased

Effect

Low input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowInputPowerAlarmClear

Table 108. transceiverLowInputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverLowInputPowerAlarmClear

Default severity

informational

Message format string

The input power measured for the transceiver associated with interface interface_name has increased above low_threshold dBm

Cause

The input power of the optics has increased

Effect

Low input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowInputPowerWarning

Table 109. transceiverLowInputPowerWarning properties

Property name

Value

Application name

chassis

Event name

transceiverLowInputPowerWarning

Default severity

warning

Message format string

The input power measured for the transceiver associated with interface interface_name has decreased to low_threshold dBm or less

Cause

The input power of the optics has decreased

Effect

Low input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowInputPowerWarningClear

Table 110. transceiverLowInputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverLowInputPowerWarningClear

Default severity

informational

Message format string

The input power measured for the transceiver associated with interface interface_name has increased above low_threshold dBm

Cause

The input power of the optics has increased

Effect

Low input power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowLaserBiasCurrentAlarm

Table 111. transceiverLowLaserBiasCurrentAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverLowLaserBiasCurrentAlarm

Default severity

critical

Message format string

The laser bias current supplied to the transceiver associated with interface interface_name has decreased to low_threshold mA or less

Cause

The laser bias current of the optics has decreased

Effect

Low laser bias current may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowLaserBiasCurrentAlarmClear

Table 112. transceiverLowLaserBiasCurrentAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverLowLaserBiasCurrentAlarmClear

Default severity

informational

Message format string

The laser bias current supplied to the transceiver associated with interface interface_name has increased above low_threshold mA

Cause

The laser bias current of the optics has increased

Effect

Low laser bias current may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowLaserBiasCurrentWarning

Table 113. transceiverLowLaserBiasCurrentWarning properties

Property name

Value

Application name

chassis

Event name

transceiverLowLaserBiasCurrentWarning

Default severity

warning

Message format string

The laser bias current supplied to the transceiver associated with interface interface_name has decreased to low_threshold mA or less

Cause

The laser bias current of the optics has decreased

Effect

Low laser bias current may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowLaserBiasCurrentWarningClear

Table 114. transceiverLowLaserBiasCurrentWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverLowLaserBiasCurrentWarningClear

Default severity

informational

Message format string

The laser bias current supplied to the transceiver associated with interface interface_name has increased above low_threshold mA

Cause

The laser bias current of the optics has increased

Effect

Low laser bias current may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowOutputPowerAlarm

Table 115. transceiverLowOutputPowerAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverLowOutputPowerAlarm

Default severity

critical

Message format string

The output power measured for the transceiver associated with interface interface_name has decreased to low_threshold dBm or less

Cause

The output power of the optics has decreased

Effect

Low output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowOutputPowerAlarmClear

Table 116. transceiverLowOutputPowerAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverLowOutputPowerAlarmClear

Default severity

informational

Message format string

The output power measured for the transceiver associated with interface interface_name has increased above low_threshold dBm

Cause

The output power of the optics has increased

Effect

Low output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowOutputPowerWarning

Table 117. transceiverLowOutputPowerWarning properties

Property name

Value

Application name

chassis

Event name

transceiverLowOutputPowerWarning

Default severity

warning

Message format string

The output power measured for the transceiver associated with interface interface_name has decreased to low_threshold dBm or less

Cause

The output power of the optics has decreased

Effect

Low output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverLowOutputPowerWarningClear

Table 118. transceiverLowOutputPowerWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverLowOutputPowerWarningClear

Default severity

informational

Message format string

The output power measured for the transceiver associated with interface interface_name has increased above low_threshold dBm

Cause

The output power of the optics has increased

Effect

Low output power may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleDown

Table 119. transceiverModuleDown properties

Property name

Value

Application name

chassis

Event name

transceiverModuleDown

Default severity

warning

Message format string

The transceiver associated with the interface interface_name is now down

Cause

The transceiver oper-state has transitioned from the up state to any lower state

Effect

The transceiver is not operational

Raising event

N/A

Clearing event

N/A

transceiverModuleHighTemperatureAlarm

Table 120. transceiverModuleHighTemperatureAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverModuleHighTemperatureAlarm

Default severity

critical

Message format string

The temperature of the transceiver associated with the interface interface_name has increased to high_threshold degrees C or more

Cause

The temperature of the transceiver module has increased

Effect

High temperatures may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleHighTemperatureAlarmClear

Table 121. transceiverModuleHighTemperatureAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverModuleHighTemperatureAlarmClear

Default severity

informational

Message format string

The temperature of the transceiver associated with the interface interface_name has decreased below high_threshold degrees C

Cause

The temperature of the transceiver module has decreased

Effect

High temperatures may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleHighTemperatureWarning

Table 122. transceiverModuleHighTemperatureWarning properties

Property name

Value

Application name

chassis

Event name

transceiverModuleHighTemperatureWarning

Default severity

warning

Message format string

The temperature of the transceiver associated with the interface interface_name has increased to high_threshold degrees C or more

Cause

The temperature of the transceiver module has increased

Effect

High temperatures may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleHighTemperatureWarningClear

Table 123. transceiverModuleHighTemperatureWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverModuleHighTemperatureWarningClear

Default severity

informational

Message format string

The temperature of the transceiver associated with the interface interface_name has decreased below high_threshold degrees C

Cause

The temperature of the transceiver module has decreased

Effect

High temperatures may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleHighVoltageAlarm

Table 124. transceiverModuleHighVoltageAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverModuleHighVoltageAlarm

Default severity

critical

Message format string

The voltage of the transceiver associated with the interface interface_name has increased to high_threshold Volts or more

Cause

The voltage supplied to the transceiver module has increased

Effect

High voltages may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleHighVoltageAlarmClear

Table 125. transceiverModuleHighVoltageAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverModuleHighVoltageAlarmClear

Default severity

informational

Message format string

The voltage of the transceiver associated with the interface interface_name has decreased below high_threshold Volts

Cause

The voltage supplied to the transceiver module has decreased

Effect

High voltages may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleHighVoltageWarning

Table 126. transceiverModuleHighVoltageWarning properties

Property name

Value

Application name

chassis

Event name

transceiverModuleHighVoltageWarning

Default severity

warning

Message format string

The voltage of the transceiver associated with the interface interface_name has increased to high_threshold Volts or more

Cause

The voltage supplied to the transceiver module has increased

Effect

High voltages may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleHighVoltageWarningClear

Table 127. transceiverModuleHighVoltageWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverModuleHighVoltageWarningClear

Default severity

informational

Message format string

The voltage of the transceiver associated with the interface interface_name has decreased below high_threshold Volts

Cause

The voltage supplied to the transceiver module has decreased

Effect

High voltages may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleLowTemperatureAlarm

Table 128. transceiverModuleLowTemperatureAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverModuleLowTemperatureAlarm

Default severity

critical

Message format string

The temperature of the transceiver associated with the interface interface_name has decreased to low_threshold degrees C or less

Cause

The temperature of the transceiver module has decreased

Effect

Low temperatures may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleLowTemperatureAlarmClear

Table 129. transceiverModuleLowTemperatureAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverModuleLowTemperatureAlarmClear

Default severity

informational

Message format string

The temperature of the transceiver associated with the interface interface_name has increased above low_threshold degrees C

Cause

The temperature of the transceiver module has increased

Effect

Low temperatures may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleLowTemperatureWarning

Table 130. transceiverModuleLowTemperatureWarning properties

Property name

Value

Application name

chassis

Event name

transceiverModuleLowTemperatureWarning

Default severity

warning

Message format string

The temperature of the transceiver associated with the interface interface_name has decreased to low_threshold degrees C or less

Cause

The temperature of the transceiver module has decreased

Effect

Low temperatures may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleLowTemperatureWarningClear

Table 131. transceiverModuleLowTemperatureWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverModuleLowTemperatureWarningClear

Default severity

informational

Message format string

The temperature of the transceiver associated with the interface interface_name has increased above low_threshold degrees C

Cause

The temperature of the transceiver module has increased

Effect

Low temperatures may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleLowVoltageAlarm

Table 132. transceiverModuleLowVoltageAlarm properties

Property name

Value

Application name

chassis

Event name

transceiverModuleLowVoltageAlarm

Default severity

critical

Message format string

The voltage of the transceiver associated with the interface interface_name has decreased to low_threshold Volts or less

Cause

The voltage supplied to the transceiver module has decreased

Effect

Low voltages may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleLowVoltageAlarmClear

Table 133. transceiverModuleLowVoltageAlarmClear properties

Property name

Value

Application name

chassis

Event name

transceiverModuleLowVoltageAlarmClear

Default severity

informational

Message format string

The voltage of the transceiver associated with the interface interface_name has increased above low_threshold Volts

Cause

The voltage supplied to the transceiver module has increased

Effect

Low voltages may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleLowVoltageWarning

Table 134. transceiverModuleLowVoltageWarning properties

Property name

Value

Application name

chassis

Event name

transceiverModuleLowVoltageWarning

Default severity

warning

Message format string

The voltage of the transceiver associated with the interface interface_name has decreased to low_threshold Volts or less

Cause

The voltage supplied to the transceiver module has decreased

Effect

Low voltages may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleLowVoltageWarningClear

Table 135. transceiverModuleLowVoltageWarningClear properties

Property name

Value

Application name

chassis

Event name

transceiverModuleLowVoltageWarningClear

Default severity

informational

Message format string

The voltage of the transceiver associated with the interface interface_name has increased above low_threshold Volts

Cause

The voltage supplied to the transceiver module has increased

Effect

Low voltages may affect transceiver performance

Raising event

N/A

Clearing event

N/A

transceiverModuleUp

Table 136. transceiverModuleUp properties

Property name

Value

Application name

chassis

Event name

transceiverModuleUp

Default severity

notice

Message format string

The transceiver associated with the interface interface_name is now up

Cause

The transceiver oper-state has transitioned from any other state to the up state

Effect

The transceiver is now operational

Raising event

N/A

Clearing event

N/A