platform

airflowCorrected

Table 1. airflowCorrected properties

Property name

Value

Application name

platform

Event name

airflowCorrected

Default severity

notice

Message format string

The type in slot slot now matches the dominant airflow of other modules in the system

Cause

The specified module is now part of the majority (either front to back, or back to front) fans + PSUs in the system. This clearance is triggered when a module moves from being part of the minority to the majority, typically through other modules being plugged/unplugged.

Effect

The specified module is providing correct airflow to the system.

Raising event

airflowMismatch

Clearing event

N/A

airflowMismatch

Table 2. airflowMismatch properties

Property name

Value

Application name

platform

Event name

airflowMismatch

Default severity

critical

Message format string

The type in slot slot does not match the airflow of other modules in the system

Cause

The inserted module does not match the airflow direction of other modules in the system.

Effect

The system is working with inefficient cooling, and may trigger thermal protection.

Raising event

N/A

Clearing event

airflowCorrected

componentBooting

Table 3. componentBooting properties

Property name

Value

Application name

platform

Event name

componentBooting

Default severity

informational

Message format string

Component type slot has started initialization

Cause

The componentBooting event is generated when the active control module has started initializing the component.

Effect

The specified component has started initializing.

Raising event

N/A

Clearing event

N/A

componentDown

Table 4. componentDown properties

Property name

Value

Application name

platform

Event name

componentDown

Default severity

critical

Message format string

Component type slot is no longer operational

Cause

The componentDown event is generated when a component has transitioned from any other operational state to the down state.

Effect

The specified component is now down.

Raising event

N/A

Clearing event

componentUp

componentFailed

Table 5. componentFailed properties

Property name

Value

Application name

platform

Event name

componentFailed

Default severity

critical

Message format string

Component type slot has failed, reason reason

Cause

The componentFailed event is generated when a component has transitioned from any other operational state to the failed state.

Effect

The specified component is now failed.

Raising event

N/A

Clearing event

componentUp

componentInserted

Table 6. componentInserted properties

Property name

Value

Application name

platform

Event name

componentInserted

Default severity

notice

Message format string

Component type slot has been inserted into the system

Cause

The componentInserted event is generated when a component has been initially detected by the active control module.

Effect

The specified component is detected.

Raising event

componentRemoved, fantrayEmpty

Clearing event

N/A

componentInsertedInInvalidSlot

Table 7. componentInsertedInInvalidSlot properties

Property name

Value

Application name

platform

Event name

componentInsertedInInvalidSlot

Default severity

warning

Message format string

Component type is inserted in invalid slot slot

Cause

The componentInsertedInInvalidSlot event is generated when a component is being inserted in invalid slot.

Effect

The specified component will not be taken into use.

Raising event

N/A

Clearing event

N/A

componentLocatorDisabled

Table 8. componentLocatorDisabled properties

Property name

Value

Application name

platform

Event name

componentLocatorDisabled

Default severity

notice

Message format string

Locator LED disabled on type slot

Cause

The componentLocatorDisabled event is generated when the locator LED for the component has been disabled, either via timeout, or via operator action.

Effect

The specified component's LED is no longer flashing with locator functionality.

Raising event

N/A

Clearing event

N/A

componentLocatorEnabled

Table 9. componentLocatorEnabled properties

Property name

Value

Application name

platform

Event name

componentLocatorEnabled

Default severity

notice

Message format string

Locator LED enabled on type slot for duration seconds

Cause

The componentLocatorEnabled event is generated when the locator LED for the component has been enabled by an operator action.

Effect

The specified component's LED is now flashing with locator functionality.

Raising event

N/A

Clearing event

N/A

componentPowerDown

Table 10. componentPowerDown properties

Property name

Value

Application name

platform

Event name

componentPowerDown

Default severity

critical

Message format string

Component type slot is being powered down due to insufficient power capacity

Cause

The componentPowerDown event is generated when a component is being powered off by the active control module as a means to bring the overall power consumption of the chassis down to a level the available power supplies are able to accommodate.

Effect

The specified component is powering down.

Raising event

N/A

Clearing event

componentPowerUp

componentPowerUp

Table 11. componentPowerUp properties

Property name

Value

Application name

platform

Event name

componentPowerUp

Default severity

warning

Message format string

Component type slot is being powered up due to sufficient power capacity

Cause

The componentPowerUp event is generated when a component is being powered on by the active control module, following on from a power down as a result of insufficient power supplies. This event is not generated during normal power on events.

Effect

The specified component is powering on.

Raising event

componentPowerDown

Clearing event

N/A

componentRemoved

Table 12. componentRemoved properties

Property name

Value

Application name

platform

Event name

componentRemoved

Default severity

critical

Message format string

Component type slot has been removed from the system

Cause

The componentRemoved event is generated when a component has is no longer detected in the system. This does not necessarily indicate that the component has been physically removed, but indicates that it is no longer detected by the active control module.

Effect

The specified component is no longer detected by the active control module.

Raising event

N/A

Clearing event

componentInserted

componentRestarted

Table 13. componentRestarted properties

Property name

Value

Application name

platform

Event name

componentRestarted

Default severity

critical

Message format string

Component type slot has been restarted

Cause

The componentRestarting event is generated when the a component has been restarted.

Effect

The specified component has been restarted.

Raising event

N/A

Clearing event

N/A

componentTemperatureExceeded

Table 14. componentTemperatureExceeded properties

Property name

Value

Application name

platform

Event name

componentTemperatureExceeded

Default severity

warning

Message format string

Component type slot has exceeded its temperature threshold, current temperature temperatureC

Cause

The componentTemperatureExceeded event is generated when the component has exceeded its temperature threshold.

Effect

The specified component has a temperature sensor that is overheating, the component may shut down by thermal protection.

Raising event

N/A

Clearing event

componentTemperatureNormal

componentTemperatureFailure

Table 15. componentTemperatureFailure properties

Property name

Value

Application name

platform

Event name

componentTemperatureFailure

Default severity

warning

Message format string

Component type slot has exceeded its safe operating temperature, component will be powered down in 10 seconds. Current temperature temperatureC

Cause

The componentTemperatureFailure event is generated when the component has exceeded its maximum temperature.

Effect

The specified component has a temperature sensor that has overheated, the component will shut down in 10 seconds for thermal protection.

Raising event

N/A

Clearing event

componentTemperatureNormal

componentTemperatureNormal

Table 16. componentTemperatureNormal properties

Property name

Value

Application name

platform

Event name

componentTemperatureNormal

Default severity

notice

Message format string

Component type slot temperature is now normal, current temperature temperatureC

Cause

The componentTemperatureNormal event is generated when the component has recovered from a temperature exceeded state.

Effect

The specified component is now within temperature operating limits.

Raising event

componentTemperatureExceeded, componentTemperatureFailure

Clearing event

N/A

componentUp

Table 17. componentUp properties

Property name

Value

Application name

platform

Event name

componentUp

Default severity

notice

Message format string

Component type slot is now operational

Cause

The componentUp event is generated when a component has transitioned from any other operational state to the up state.

Effect

The specified component is now up.

Raising event

componentDown, componentFailed

Clearing event

N/A

controlModuleActivityChange

Table 18. controlModuleActivityChange properties

Property name

Value

Application name

platform

Event name

controlModuleActivityChange

Default severity

critical

Message format string

Control module slot has become activity_state

Cause

The controlModuleActivityChange event is generated when there has been an activity change on either control module.

Effect

The specified control module has transitioned to the specified state.

Raising event

N/A

Clearing event

N/A

controlModuleConfigSynchronized

Table 19. controlModuleConfigSynchronized properties

Property name

Value

Application name

platform

Event name

controlModuleConfigSynchronized

Default severity

informational

Message format string

Configuration synchronization with standby control module standby_slot has succeeded

Cause

Configuration has been successfully synchronized between the active and standby control modules.

Effect

The standby control module now has the same configuration as the active.

Raising event

N/A

Clearing event

N/A

controlModuleImageSynchronized

Table 20. controlModuleImageSynchronized properties

Property name

Value

Application name

platform

Event name

controlModuleImageSynchronized

Default severity

informational

Message format string

Image synchronization with standby control module standby_slot has succeeded

Cause

Images have been successfully synchronized between the active and standby control modules.

Effect

The standby control module now has the same images as the active.

Raising event

N/A

Clearing event

N/A

controlModuleInSync

Table 21. controlModuleInSync properties

Property name

Value

Application name

platform

Event name

controlModuleInSync

Default severity

informational

Message format string

Active and standby control modules are now synchronized

Cause

All synchronization activities have completed between the active and standby control modules.

Effect

The standby control module is now ready for a control module switchover, if necessary.

Raising event

controlModuleSyncLost

Clearing event

N/A

controlModuleOverlaySynchronized

Table 22. controlModuleOverlaySynchronized properties

Property name

Value

Application name

platform

Event name

controlModuleOverlaySynchronized

Default severity

informational

Message format string

Overlay synchronization with standby control module standby_slot has succeeded

Cause

Overlays have been successfully synchronized between the active and standby control modules.

Effect

The standby control module now has the same overlay as the active.

Raising event

N/A

Clearing event

N/A

controlModuleSyncLost

Table 23. controlModuleSyncLost properties

Property name

Value

Application name

platform

Event name

controlModuleSyncLost

Default severity

critical

Message format string

Active control module has lost visibility of the standby control module

Cause

Connection between the active and standby control modules has been lost.

Effect

The standby control module is no longer capable of taking over in the event of a failure of the active, no configuration or images are being synchronized.

Raising event

N/A

Clearing event

controlModuleInSync

controlModuleSyncStart

Table 24. controlModuleSyncStart properties

Property name

Value

Application name

platform

Event name

controlModuleSyncStart

Default severity

informational

Message format string

Active and standby control modules are now synchronizing synchronization_category

Cause

A synchronization has been triggered between the active and standby control modules.

Effect

Configuration, images, or persistent storage is being synchronized between the active and standby control module.

Raising event

N/A

Clearing event

N/A

fantrayEmpty

Table 25. fantrayEmpty properties

Property name

Value

Application name

platform

Event name

fantrayEmpty

Default severity

critical

Message format string

Component fan-tray slot is not present in the system

Cause

The fantrayEmpty event is generated when a fan-tray has transitioned from any other operational state to the empty state, or is never present.

Effect

The system may have cooling issues.

Raising event

N/A

Clearing event

componentInserted

fips140ConfiguredOperDown

Table 26. fips140ConfiguredOperDown properties

Property name

Value

Application name

platform

Event name

fips140ConfiguredOperDown

Default severity

critical

Message format string

FIPS-140 is enabled operationally down for reason down-reason

Cause

FIPS-140 has been successfully configured but it is oper-down because of an error.

Effect

None

Raising event

N/A

Clearing event

N/A

fips140ConfiguredOperUp

Table 27. fips140ConfiguredOperUp properties

Property name

Value

Application name

platform

Event name

fips140ConfiguredOperUp

Default severity

notice

Message format string

FIPS-140 has been enabled and fully operational

Cause

FIPS-140 is successfully enabled and operational.

Effect

None

Raising event

N/A

Clearing event

N/A

fips140ConfiguredWaitingReboot

Table 28. fips140ConfiguredWaitingReboot properties

Property name

Value

Application name

platform

Event name

fips140ConfiguredWaitingReboot

Default severity

notice

Message format string

FIPS-140 is enabled but operationally down until next reboot

Cause

FIPS-140 has been successfully configured.

Effect

FIPS-140 active after next reboot

Raising event

N/A

Clearing event

N/A

fips140NotActive

Table 29. fips140NotActive properties

Property name

Value

Application name

platform

Event name

fips140NotActive

Default severity

notice

Message format string

FIPS-140 is not activated

Cause

FIPS-140 is not configured.

Effect

None

Raising event

N/A

Clearing event

N/A

fips140Removed

Table 30. fips140Removed properties

Property name

Value

Application name

platform

Event name

fips140Removed

Default severity

notice

Message format string

FIPS-140 has been disabled but is operationally up until next reboot

Cause

FIPS-140 has been successfully unconfigured.

Effect

FIPS-140 inactive after next reboot.

Raising event

N/A

Clearing event

N/A

linecardCapacityDegraded

Table 31. linecardCapacityDegraded properties

Property name

Value

Application name

platform

Event name

linecardCapacityDegraded

Default severity

critical

Message format string

Linecard slot forwarding complex forwarding-complex fabric capacity degraded

Cause

The specified linecard's forwarding complex has insufficient operational fabric links.

Effect

Packets may be dropped if the linecard's forwarding complex is sending and receiving significant amounts of traffic to the fabric.

Raising event

N/A

Clearing event

linecardCapacityNormal

linecardCapacityNormal

Table 32. linecardCapacityNormal properties

Property name

Value

Application name

platform

Event name

linecardCapacityNormal

Default severity

informational

Message format string

Linecard slot forwarding complex forwarding-complex fabric capacity normal

Cause

The specified linecard's forwarding complex has sufficient operational fabric links again.

Effect

Normal behavior is restored for sending and receiving traffic to the fabric.

Raising event

linecardCapacityDegraded

Clearing event

N/A

platformLowPower

Table 33. platformLowPower properties

Property name

Value

Application name

platform

Event name

platformLowPower

Default severity

emergency

Message format string

Insufficient power for currently installed components, current_powerW available, required_powerW required

Cause

Available power from operational power supplies is insufficient to power all components in the system.

Effect

Components in the system will be powered down until required power is lower than what is supplied by operational power supplies.

Raising event

N/A

Clearing event

platformNormalPower

platformLowReservePower

Table 34. platformLowReservePower properties

Property name

Value

Application name

platform

Event name

platformLowReservePower

Default severity

critical

Message format string

Insufficient reserve power for currently installed components, current_powerW available, required_powerW required

Cause

Available power is less than one power supply capacity extra to power all components in the system.

Effect

Power will be insufficient if one operational power supply is lost.

Raising event

N/A

Clearing event

platformNormalPower

platformNoPowerRedundancy

Table 35. platformNoPowerRedundancy properties

Property name

Value

Application name

platform

Event name

platformNoPowerRedundancy

Default severity

warning

Message format string

Power redundancy based on mode redundancy_mode is not available, required PSUs required_psus, operational PSUs active_psus

Cause

The available PSUs are not able to accomodate the configured power redundancy mode.

Effect

The desired power redundancy is not available.

Raising event

N/A

Clearing event

platformPowerRedundancyRecovered

platformNormalPower

Table 36. platformNormalPower properties

Property name

Value

Application name

platform

Event name

platformNormalPower

Default severity

informational

Message format string

Sufficient power for currently installed components, current_powerW available, required_powerW required

Cause

Available power from operational power supplies is sufficient to power all components in the system.

Effect

Enough power is available.

Raising event

platformLowPower, platformLowReservePower

Clearing event

N/A

platformPowerRedundancyRecovered

Table 37. platformPowerRedundancyRecovered properties

Property name

Value

Application name

platform

Event name

platformPowerRedundancyRecovered

Default severity

informational

Message format string

Power redundancy based on mode redundancy_mode is available, required PSUs required_psus, operational PSUs active_psus

Cause

The available PSUs are able to accomodate the configured power redundancy mode.

Effect

The desired power redundancy is available.

Raising event

platformNoPowerRedundancy

Clearing event

N/A

psuInputDown

Table 38. psuInputDown properties

Property name

Value

Application name

platform

Event name

psuInputDown

Default severity

warning

Message format string

Power input on power-supply slot is down

Cause

Input fault on the specified power supply is set.

Effect

The specified power supply can no longer supply power to the system.

Raising event

N/A

Clearing event

psuInputUp

psuInputUp

Table 39. psuInputUp properties

Property name

Value

Application name

platform

Event name

psuInputUp

Default severity

notice

Message format string

Power input on power-supply slot is up

Cause

Input fault on the specified power supply is clear.

Effect

The specified power supply can now supply power to the system.

Raising event

psuInputDown

Clearing event

N/A

psuOutputDown

Table 40. psuOutputDown properties

Property name

Value

Application name

platform

Event name

psuOutputDown

Default severity

warning

Message format string

Power output on power-supply slot is down

Cause

Output fault on the specified power supply is set.

Effect

The specified power supply can no longer supply power to the system.

Raising event

N/A

Clearing event

psuOutputUp

psuOutputUp

Table 41. psuOutputUp properties

Property name

Value

Application name

platform

Event name

psuOutputUp

Default severity

notice

Message format string

Power output on power-supply slot is up

Cause

Output fault on the specified power supply is clear.

Effect

The specified power supply can now supply power to the system.

Raising event

psuOutputDown

Clearing event

N/A

psuTemperatureFault

Table 42. psuTemperatureFault properties

Property name

Value

Application name

platform

Event name

psuTemperatureFault

Default severity

warning

Message format string

Component type slot has raised a temperature fault, current temperature temperatureC

Cause

The psuTemperatureFault event is generated when the power supply raises a temperature fault.

Effect

The power supply is overheating, and may shut down by thermal protection.

Raising event

N/A

Clearing event

psuTemperatureNormal

psuTemperatureNormal

Table 43. psuTemperatureNormal properties

Property name

Value

Application name

platform

Event name

psuTemperatureNormal

Default severity

notice

Message format string

Component type slot temperature fault is now clear, current temperature temperatureC

Cause

The psuTemperatureNormal event is generated when the power supply recovered from a temperature fault state.

Effect

The power supply is now within temperature operating limits.

Raising event

psuTemperatureFault

Clearing event

N/A

systemInServiceSoftwareUpgrade

Table 44. systemInServiceSoftwareUpgrade properties

Property name

Value

Application name

platform

Event name

systemInServiceSoftwareUpgrade

Default severity

critical

Message format string

System is upgrading from old_version to new_version, utilizing warm reboot

Cause

The systemInServiceSoftwareUpgrade event is generated when a software triggered in service software upgrade request has been made.

Effect

The control and management plane of the system will go offline, the datapath will continue forwarding based on current state. The system will upgrade the kernel, operating system, and/or applications as needed.

Raising event

N/A

Clearing event

N/A

systemReboot

Table 45. systemReboot properties

Property name

Value

Application name

platform

Event name

systemReboot

Default severity

critical

Message format string

System going down for reboot

Cause

The systemReboot event is generated when a software triggered reboot has been made.

Effect

The system will go offline for reboot

Raising event

N/A

Clearing event

N/A

systemWarmReboot

Table 46. systemWarmReboot properties

Property name

Value

Application name

platform

Event name

systemWarmReboot

Default severity

critical

Message format string

System going down for warm reboot

Cause

The systemWarmReboot event is generated when a software triggered warm reboot has been made.

Effect

The control and management plane of the system will go offline, the datapath will continue forwarding based on current state.

Raising event

N/A

Clearing event

N/A

systemWarmRebootAborted

Table 47. systemWarmRebootAborted properties

Property name

Value

Application name

platform

Event name

systemWarmRebootAborted

Default severity

critical

Message format string

System has aborted a requested warm reboot due to reason

Cause

The systemWarmRebootAborted event is generated when a software triggered warm reboot request has been aborted, typically due to unsupported configuration.

Effect

The in progress warm reboot has been aborted, no effect to system configuration or state.

Raising event

N/A

Clearing event

N/A