Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear inc. OCN alarms.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. OCN alarm in the resulting alarm list. | ||||||
2 |
Determine the alarm level(s) for the active inc. OCN alarm(s). Clear the alarms in order of severity. | ||||||
3 |
Refer to the Probable Cause column in the alarm list, determine the affected OC-N line, and note the corresponding AID. | ||||||
4 |
Visually check the local receive fiber connections between the circuit pack faceplate/pluggable transmission module and the LGX panel or equivalent connection point for faulty connections or damage.
| ||||||
5 |
From the System View, click the Alarm List button and click Refresh. | ||||||
6 |
Is the inc. OCN alarm still present?
| ||||||
7 |
| ||||||
8 |
Disconnecting cables and/or replacing pluggable transmission modules may disrupt service. Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a luggable transmission module. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure. Replace the affected local pluggable transmission module. Reference: Procedure 6-8: Replace pluggable transmission module | ||||||
9 |
From the System View, click the Alarm List button and click Refresh. | ||||||
10 |
Is the inc. OCN alarm still present?
| ||||||
11 |
Disconnecting cables and/or replacing circuit packs may disrupt service. Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a circuit pack. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure. Replace the affected local OC-N OLIU circuit pack. Reference: | ||||||
12 |
From the System View, click the Alarm List button and click Refresh. | ||||||
13 |
Is the inc. OCN alarm still present?
| ||||||
14 |
Important! At this point, the local network element is operating correctly. The trouble is in the far-end network element or in the fiber/cable between the far-end network element and the local network element. Follow local procedures for addressing OCN-related conditions/alarms at the far-end network element. | ||||||
15 |
From the System View at the local network element, click the Alarm List button and click Refresh. | ||||||
16 |
Is the inc. OCN alarm still present?
| ||||||
17 |
Follow local procedures to isolate and clear the fiber/cable trouble between the far-end network element and the local network element. End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |