Procedure 4-13: Install 10/100 Ethernet circuit packs

- Overview

Use this procedure to install the following 10/100 Ethernet circuit packs:

  • LNW66 10/100-FE

  • LNW71 10/100-PL

  • LNW74 10/100-T/F

Equipage guidelines (Main slots not equipped with Very Large Fabric circuit packs)

If the Main slots are not equipped with Very Large Fabric LNW84 or LNW141 OLIU circuit packs, the LNW66/LNW71/LNW74 Ethernet circuit packs are supported in slot 1 or slot 2 of Function/Growth group D and/or G. However, it is recommended that the LNW66/LNW71/LNW74 Ethernet circuit pack be installed in Function/Growth slot D1 and/or G1. A 177D apparatus blank or an LNW98 Detectable Blank circuit pack must be installed in the unequipped companion Function/Growth slot.

Equipage guidelines (Main slots equipped with Very Large Fabric circuit packs)

If the Main slots are equipped with Very Large Fabric OLIU circuit packs, the circuit packs in a Function/Growth group may be the same or different circuit pack type depending on the Slot Protection State.

For Ethernet circuit packs, the Slot Protection State parameter is fixed Unprotected. If the Slot Protection State is Protected and a 10/100 Ethernet circuit pack is installed, the system reports an unexpected CP type alarm and service may be impacted.

The following combinations of 0x1 compatible circuit pack types are supported in Function/Growth Slot 1 and Slot 2 when the Slot Protection State is Unprotected.

Slot 2

Slot 1

LNW66/LNW71

LNW74 (S1:2 and later)

LNW70 (S1:3 and later)/ LNW78

Other Front Access Circuit Packs 1

LNW66/LNW71

Not compatible

Not compatible

Not compatible

Compatible

LNW74 (S1:2 and later)

Not compatible

Compatible 2

Compatible

Compatible

LNW70 (S1:3 and later)/ LNW78

Not compatible

Compatible

Compatible

Compatible

Other Front Access Circuit Packs 1

Compatible

Compatible

Compatible

Compatible

Notes:
  1. This includes the LNW63, LNW64, LNW67, LNW68, LNW73/73C, LNW87, LNW170, LNW785, and all low-speed OLIU circuit packs. The LNW6, LNW7, LNW8, LNW16, LNW18, LNW19/19B, LNW20, LNW39, LNW70 (S1:2 and earlier), LNW74 (S1:1), LNW391, LNW801, LNW111, and LNW112 are not 0x1 compatible.

  2. The circuit pack Ethernet Mode parameter must be provisioned as FX to support LNW74 circuit packs in slot 1 and slot 2; otherwise, this configuration is incompatible.

If an incompatible circuit pack is installed in a Function/Growth slot, the system reports a CP not allowed - eqpt alarm.

Select View → Equipment to access the circuit pack details and determine the value of the Slot Protection State parameter.

The Slot Protection State parameter can be changed from Protected to Unprotected or from Unprotected to Protected. If required, refer to Procedure 4-23: Change slot protection state.

- Privilege level

You must log in as a Privileged, General, Maintenance, or Reports Only user to complete this procedure.

Required equipment

Use only Alcatel-Lucent Approved Class 1 SFP transceivers in the LNW74 10/100-T/F circuit pack. Refer to the list of Class 1 SFP/XFP transceivers that are approved by Alcatel-Lucent in Procedure 4-16: Install pluggable transmission modules.

Refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Installation Manual, 365-372-327, as required, when removing and/or installing pluggable transmission modules.

Ethernet port configurations (LNW74 circuit pack only)

When the Main slots are equipped with VLF OLIU circuit packs, the LNW74 circuit pack supports the following provisionable Ethernet port configurations .

Ethernet port mode parameter setting

Description

FT_FX

Electrical FE Backplane Ports 1–16: Enabled

Ports 17–24: optical FE

FX

Electrical FE Backplane Ports 1–16: Disabled

Ports 17–24: optical FE

- Before you begin

Prior to performing this procedure:

  1. Refer to Required equipment and Before you begin in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

  3. Obtain the work instructions for this procedure.

  4. Ensure that the appropriate Ethernet circuit pack is available for installation.

  5. If required, ensure that correct pluggable transmission modules are available for installation in the LNW74 circuit pack.

  6. Use the work instructions and select View → Equipment to access the circuit pack details and determine if the Main slots are equipped with Very Large Fabric LNW84 or LNW141 OLIU circuit packs.

Steps

Complete the following steps to install a 10/100 Ethernet circuit pack.

 
1

Determine the Function/Growth slots being equipped with circuit pack.

Reference:


2

For the LNW74 circuit pack only, ensure all optical fiber connectors and couplings are properly cleaned, if required.

Important!

Signal performances may be degraded if the connections and couplings are not cleaned properly.

Reference:

Procedure 14-3: Clean optical fibers, dual LC adapters and LC lightguide buildouts (LBOs)


3

Important!

Pluggable transmission modules are shipped with a dust cover installed into the optical ports to maintain cleanliness during storage and/or transportation. It is recommended that the dust cover be kept in place to maintain cleanliness until the optical fiber is connected. With proper care and handling, cleaning the pluggable transmission modules should not be necessary.

If required, clean any optical pluggable transmission modules being used.

Reference:

Procedure 14-28: Clean optical pluggable transmission module


4

Holding the pack vertically, rotate the pack 90 degrees to the right (clockwise). The faceplate label with LNW66/LNW71/LNW74 should be on your right, next to the fan unit.


5

Open both faceplate latches and seat the circuit pack in the required Function/Growth slot by applying steady pressure to both faceplate latches.

Result:

If a factory-fresh circuit pack is inserted, a firmware Smart Apply may begin (this is indicated by a blinking ACTIVE LED). The Smart Apply may take from 5–8 minutes and the user should wait for it to complete.

If the Smart Apply does not occur, the FAULT LED on the circuit pack lights. After approximately 100 seconds, the ACTIVE LED lights and the FAULT LED goes off.

Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation.


6

Important!

The LNW74 circuit pack ports 17–24 may be equipped with up to eight pluggable transmission modules and supports different Ethernet port configurations. Refer to Ethernet port configurations (LNW74 circuit pack only).

If required, install pluggable transmission modules.

Reference:

Procedure 4-16: Install pluggable transmission modules


7

If the companion Function/Growth slot is unequipped, install either a 177D apparatus blank or an LNW98 Detectable Blank circuit pack in the unequipped companion Function/Growth slot.


8

From the System View menu, select View → Equipment.

Result:

The View Equipment window opens.


9

Verify presence of the new circuit pack in the equipment list.


10

Select (highlight) the new circuit pack, then click Select at bottom of window.

Result:

Circuit pack parameter values display on right side of window.


11

Verify that the Circuit Pack State for the circuit pack reads In Service.


12

Click Close to exit.


13

From the System View window, click the Alarm List button to verify that no alarms are present for the ports on the circuit packs just installed.

Result:

The NE Alarm List appears. No alarms should be present for the circuit pack just installed.


14

If required, provision the circuit pack and/or port parameters.

Important!

When a new Ethernet circuit pack is installed, Ethernet PM reporting is enabled and TCA reporting is disabled for each port and VCG. If changes are required, refer to Procedure 8-5: Provision performance monitoring (PM) settings.

Reference:

Procedure 4-15: Provision Ethernet circuit packs/LAN port/VCG for service


End of steps