Procedure 4-6: Install DS1/DS3/16/3 circuit packs

- Overview

Use this procedure to install the LNW39 and LNW391 DS1/DS3/16/3 combination circuit pack(s).

Important!

The LNW39 and LNW391 circuit packs have common funtionality; however, they are not directly interchangeable. Therefore, the LNW39 and LNW391 circuit packs cannot occupy the same Function group together.

Important!

If the Main slots are equipped with LNW84 OC3/OC12/OC48, LNW140 OC-3/DS1, or LNW141 OC-192 circuit packs, the DS1/DS3/16/3 combination circuit pack is not supported.

- Privilege level

You must log in as a Privileged or General user to complete this procedure.

- Before you begin

Prior to beginning this procedure:

  1. Refer to Required equipment and Before you begin in this chapter.

  2. Refer to Electrostatic discharge.

  3. Ensure that DS1/DS3/16/3 circuit pack(s) is available for installation.

Steps

Complete the following steps to install DS1/DS3/16/3 circuit pack(s).

 
1

Determine from office records or circuit order the length of the DS1 and DS3 cabling between the Alcatel-Lucent 1665 DMXtend and the DSX-1/3 cross-connect points and any other circuit pack parameters to be set.


2

Holding the circuit pack vertically, rotate the circuit pack 90 degrees to the left (counter-clockwise). The faceplate label with LNW39/LNW391 should be on your left, away from the fan unit.


3

Open the faceplate latch and seat the circuit pack in slot A1/B1 by applying steady pressure to the faceplate and latch assembly.

Result:

The FAULT LED and ACTIVE LED lights. The FAULT LED begins flashing after about 20 seconds. (Firmware updates may take place that add additional wait time.)

Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation.


4

Secure the circuit pack in the shelf using the latch lever and thumbscrew.


5

Is a second (protection) DS1/DS3/16/3 circuit pack required in Function group slot A2/B2?

If...

Then...

Yes

Continue with Step 6.

No

Insert LNW43 Application Blank or LNW96 Detectable Blank circuit pack into the unequipped Function group slot A2/B2. If an LNW96 Detectable Blank circuit pack was installed, select View → Refresh Equipment. Click on the slot just equipped and Select to view the circuit pack in the system view.

Proceed to Step 9.


6

Holding the circuit pack vertically, rotate the circuit pack 90 degrees to the left (counter-clockwise). The faceplate label with LNW39/LNW391 should be on your left, away from the fan unit.


7

Open the faceplate latch and seat the circuit pack in slot A2/B2 by applying steady pressure to the faceplate and latch assembly.

Result:

The FAULT LED and ACTIVE LED lights. The FAULT LED begins flashing after about 20 seconds. (Firmware updates may take place that add additional wait time.)

Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation.


8

Secure the circuit pack in the shelf using the latch lever and thumbscrew.


9

From the System View window, click the Alarm List button to verify that no alarms, loopbacks, protection switch lockouts, or protection switches are present for the ports on the circuit packs just installed.

Result:

The NE Alarm List appears. No alarms should be present for the circuit pack(s) just installed.


10

Do you wish to provision circuit pack and/or port parameters at this time?

If...

Then...

Yes

Refer to Procedure 4-10: Provision DS1/E1 circuit packs/ports for service and Procedure 4-8: Provision DS3/EC1 circuit packs/ports for service.

No

STOP! End of Procedure.


End of steps