Procedure 14-9: Perform DS1/E1 transmission test

- Overview

Use this procedure to test a DS1 or E1 port at a stand-alone Alcatel-Lucent 1665 DMXtend shelf or in an Alcatel-Lucent 1665 DMXtend network.

If this procedure is being used to perform end-to-end testing in an Alcatel-Lucent 1665 DMXtend network, it is assumed that the complete Alcatel-Lucent 1665 DMXtend network configuration (UPSR, 1+1, or Bidirectional 1+1) has already been established/tested and that only a particular DS1 or E1 port is being tested at this time.

In end-to-end testing, one shelf is referred to as the near end and the other shelf as the far end. These designations are arbitrary; either shelf can be the near-end or the far-end shelf.

Important!

The LNW18 and LNW20 TMUX circuit packs do not support the DS1 port transmission tests.

Important!

The Port Maintenance parameter for the affected ports must be provisioned Allow to perform this procedure. If the Port Maintenance parameter for the affected ports is provisioned to Inhibit, loopback and test transmission commands for the affected ports are denied.

To view the Port Maintenance parameter, a Privileged, General, Maintenance, or Reports Only user must select Administration → Allow/Inhibit Port Maintenance to access the required port.

To provision the Port Maintenance parameter, a Privileged user must perform Procedure 7-23: Allow/inhibit port/tributary maintenance.

- Privilege level

You must log in as either a Privileged or General user to complete this procedure.

Required equipment

In addition to the equipment listed in Required equipment, a DS1 or E1 Test Set is also required.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

  3. Obtain the work instructions for this procedure and note the assigned AIDs.

  4. Select View → Equipment to access the required DS1/E1 port and verify that the DS1/E1 port parameters have been provisioned correctly (according to the work instructions) at the terminating Alcatel-Lucent 1665 DMXtend shelf(s) of the circuit being tested.

    If required, select Configuration → Equipment to make DS1/E1 port provisioning changes.

    Refer to Procedure 4-10: Provision DS1/E1 circuit packs/ports for service for more information.

Steps

Complete the following steps to perform a DS1/E1 transmission test.

 
1

Important!

Proper terminating and pass-through cross-connections must exist at each shelf (including stand-alone shelves) to establish continuity for the DS1/E1 circuit being tested.

Select View → Cross-Connections to obtain a cross-connection list and verify that the proper VT1.5/STS-n (DS1) cross-connections exist for the DS1 circuit to be tested. If an E1 circuit is to be tested, verify the proper STS-3 cross-connections exist.

If required, select Configuration → Cross-Connections to access the Cross-Connection Wizard and create the proper VT1.5/STS-n cross-connections for the DS1/E1 circuit to be tested.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) TL1 Message Details, 365-372-328


2

If the transmission test is to be performed...

Then...

at a stand-alone shelf in the Terminal direction (toward the fiber),

At the required OLIUs, loop back the fiber.

Refer to Procedure 14-6: Connect OLIU optical loopbacks.

at a stand-alone shelf in the Facility direction (toward the DSX),

At the DSX-1 panel or equivalent connection point, connect a patch cord from the OUT jack to the IN jack associated with the DS1/E1 circuit being tested.

in an Alcatel-Lucent 1665 DMXtend network (end-to-end)

At the far-end DSX-1 panel or equivalent connection point, connect a patch cord from the OUT jack to the IN jack associated with the DS1/E1 circuit being tested, OR log in to the far-end Alcatel-Lucent 1665 DMXtend shelf and select Fault → Analysis → Loopback to perform a Terminal loopback on the DS1/E1 circuit being tested.

Reference:

The following figures show the test arrangements.

Figure 14-8: Stand-Alone shelf with OLIU loopback
Stand-Alone shelf with OLIU loopback
Figure 14-9: Stand-Alone shelf with DSX loopback
Stand-Alone shelf with DSX loopback
Figure 14-10: End-to-End DS1/E1 circuit with far-end loopback
End-to-End DS1/E1 circuit with far-end loopback
3

If the transmission test is to be performed...

Then...

at a stand-alone shelf in the Terminal direction (toward the fiber),

Either select Fault → Test → Transmission to perform a terminal transmission test on the DS1/E1 port, or connect a test set to the port to be tested at the DSX-1 panel or equivalent connection point and apply a DS1/E1 test signal.

at a stand-alone shelf in the Facility direction (toward the DSX),

Select Fault → Test → Transmission to perform a facility transmission test on the DS1/E1 port.

in an Alcatel-Lucent 1665 DMXtend network (end-to-end),

At the Near End, either select Fault → Test → Transmission to perform a terminal transmission test on the DS1/E1 port, or connect a test set to the port to be tested at the DSX-1 panel or equivalent connection point and apply a DS1/E1 test signal.


4

Was the test successful (error free)?

If...

Then...

Yes,

Continue with Step 5.

No,

Proceed to Step 21.


5

Is the protection slot associated with the DS1/E1 circuit under test equipped with a companion circuit pack?

If...

Then...

Yes,

Continue with Step 6.

No,

Proceed to Step 9.


6

Select Fault → Protection Switch command to perform a manual switch from the current active circuit pack to the standby circuit pack. This may cause a hit and register some errors during the switch.


7

Was the circuit pack protection switch successful (recovered error free)?

If...

Then...

Yes,

Verify that the Standby circuit pack is now Active, and repeat Step 3 for the protection circuit pack. Then continue with Step 8.

No,

Proceed to Step 21.


8

Was the test successful (error free)?

If...

Then...

Yes,

Continue with Step 9.

No,

Proceed to Step 21.


9

Are you performing this test for a stand-alone Alcatel-Lucent 1665 DMXtend shelf or for end-to-end testing within an Alcatel-Lucent 1665 DMXtend network?

If...

Then...

Stand-alone test,

Continue with Step 10.

End-to-end test,

Proceed to Step 15.


10

Remove any patch cords/fibers used to loop back the circuit under test and disconnect the test set from the DSX-1 panel or equivalent connection point, if required.


11

Delete any cross-connections entered to perform this procedure.

Reference:

Procedure 10-2: Discontinue DS1 or E1 service


12

In the System View screen, select Configuration → Update System → Update All to retire existing alarms caused by this procedure.


13

If required, repeat Step 1 through Step 12 for each DS1/E1 circuit to be tested.


14

STOP! End of Procedure.


15

At the near end, disconnect the test set from the DSX-1 panel or equivalent connection point, if required.


16

At the near end and far end, delete any cross-connections entered to perform this procedure.

Reference:

Procedure 10-2: Discontinue DS1 or E1 service


17

At the far end, select Fault → Analysis → Loopback to release the terminal loopback, or remove the patch cords at the DSX-1 panel or equivalent connection point for the circuit under test.


18

At the near end and far end, select Configuration → Update System → Update All to retire existing alarms caused by this procedure.


19

If required, return to Step 1 and repeat this procedure for each DS1/E1 circuit to be tested.


20

STOP! End of Procedure.


21

Has the circuit pack that failed this test been replaced?

If...

Then...

Yes,

Proceed to Step 23.

No,

Continue with Step 22.


22

Replace the DS1/E1 circuit pack and repeat this procedure.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326


23

Trouble may be in the DSX cross-connect wiring, T1 interface wiring, VT1.5/STS-1/STS-3 cross-connections in the network, or the shelf backplane. If you continue to experience problems, contact your next level of support.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326


End of steps