Important!
This is not a stand-alone procedure. Perform this procedure only as directed by another procedure.
Important!
When optical fibers are disconnected during this procedure, inc. LOS, section DCC channel failed, and neighbor SYSCTL CP unavailable alarms are reported. The holdover mode active condition may also be reported depending on the provisioned system timing mode.
Complete the following steps to upgrade the in-service UPSR connections at a Alcatel-Lucent 1665 DMXtend node connected to the UPSR using single-rate circuit packs in the Main slots.
1 |
If required, verify the active/standby status of the OC-3 circuit pack in Main slot M1 and perform manual switches to switch traffic away from an active circuit pack. Reference: Procedure 12-1.3: Verify active/standby status of circuit pack/port to be upgraded | ||||||
2 |
Important! The Ring Upgrade Mode is required for cross-connections and provisioning data to be mapped to the replacement circuit pack. At the WaveStar® CIT System View, select Configuration → Ring Upgrade Mode. Result: A dialog box appears asking you to confirm changing the NE Mode to Ring Upgrade Mode. Click Yes. The ABN LED is lighted on the SYSCTL circuit pack faceplate and the WaveStar® CIT Alarm List shows the Ring Upgrade Mode as Not Alarmed. For more information about the Ring Upgrade Mode, refer to Ring Upgrade Mode. | ||||||
3 |
Important! If the circuit pack is active for timing and/or transmission, opening the latch causes timing and/or transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch. Open the faceplate latch on the OC-3 OLIU circuit pack in Main slot M1. Disconnect the optical fibers from the OC-3 OLIU circuit pack in Main slot M1. Reference: | ||||||
4 |
If required at both ends of the optical span to be upgraded, perform the following to connect the replacement OC-12 circuit pack in Main slot M1 and the required OC-12 circuit pack/port at the opposite end of the upgraded OC-12 optical span:
Result: The inc. OC3 LOS alarms clear. Transmission is now supported on the upgraded optical span. Reference: Procedure 14-4: Perform connection and verification of optical facility | ||||||
5 |
Important! Perform this step only if the opposite end of the upgraded optical span is an OC-12 port in a Function/Growth group and the Optical Synchronization Source is to be reprovisioned to the upgrade OC-12 port. If required at the opposite end of the upgraded optical span, select Configuration → Timing/Sync to reprovision the Optical Synchronization Source to the upgrade OC-12 port on the OC-12 OLIU circuit pack in slot 2 of the Function/Growth group. Reference: Procedure 6-5: Network Element synchronization provisioning | ||||||
6 |
Important! The UPD/INIT button does not work during this upgrade. At the System View select Configuration → Update System → Upgrade. Select main-1 (default) as the Directed Slot Choice and click OK. Result: A dialog box appears asking you to confirm executing this command. Click Yes.
| ||||||
7 |
If required, verify the active/standby status of the OC-3 circuit pack in Main slot M2 and perform manual switches to switch traffic away from an active circuit pack. Reference: Procedure 12-1.3: Verify active/standby status of circuit pack/port to be upgraded | ||||||
8 |
Important! Do not reconnect the optical fibers until instructed to do so. The optical fibers are reconnected after the OC-3 circuit pack/port is upgraded at each end of the optical span. If the circuit pack is active for timing and/or transmission, opening the latch causes timing and/or transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch. Open the faceplate latch on the OC-3 OLIU circuit pack in Main slot M2. Disconnect the optical fibers from the OC-3 OLIU circuit pack in Main slot M2. Reference: The following figure shows the state of the current node and the adjacent optical spans. STOP! To complete the upgrade, return to the procedure that directed you to perform this procedure. End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |