Procedure 4-2: Install OLIU circuit packs in Main slots

- Overview

Use this procedure to install the following OLIU circuit packs in the Main slots:

  • LNW38 OC12/1.3/IR1

  • LNW40 OC3/1.3/IR1

  • LNW41 OC48 OLIU with one pluggable transmission module

  • LNW51 OC12/1.3/LR1

  • LNW52 OC48/1.3/LR1

  • LNW84 OC3/OC12/OC48 very large fabric multiport multirate OLIU with up to eight pluggable transmission modules or without pluggable transmission modules (headless, optics-free, switch applications), 16 DS1 ports and 3 DS3 ports

  • LNW140 OC3/1.3/IR1 + DS1

  • LNW141 OC192 very large fabric OLIU with one pluggable transmission module or without a pluggable transmission module (headless, optics-free, switch applications)

  • LNW302 OC3 with one pluggable transmission module

  • LNW380 OC12/1.5/LR2

  • LNW382 OC12 with one pluggable transmission module

  • LNW601 OC3/1.3/LR1

Important!

The OLIU circuit packs in the Main slots must both have the same optical line rate and VT cross-connect size. If the circuit packs in the Main slots have different optical line rates or VT cross-connect sizes, the system reports an unexpected CP type alarm and service may be impacted.

Important!

The LNW84 OC3/OC12/OC48, LNW140 OC3/1.3/IR1 + DS1 and LNW141 OC192 circuit packs are only compatible with the Alcatel-Lucent 1665 DMXtend Shelf with removable center dividers (DMXTEND-RCD-CE Shelf Type).

To determine the shelf type, select View → Equipment, highlight Shelf, and click Select to obtain the shelf details.

- Privilege level

You must log in as a Privileged, General, Maintenance, or Reports Only user to complete this procedure.

Required equipment

In addition to the equipment listed in Required equipment, if loopbacks are to be performed, the following equipment is also required:

  • Optical loopback cables

  • Lightguide buildouts (LBOs)

  • Optical fiber cleaning tools

Refer to the list of Class 1 SFP/XFP transceivers that are approved by Alcatel-Lucent in Procedure 4-16: Install pluggable transmission modules.

Refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Installation Manual, 365-372-327, as required, when removing and/or installing pluggable transmission modules.

A deeper shelf cover (comcode 849064282) is required for shelves equipped with LNW84 OC3/OC12/OC48 circuit packs. This shelf cover provides more space to prevent fibers from touching the front cover when the cover is closed.

Important!

Release 4.0 or later software is required to support LNW140 OC3/1.3/IR1 + DS1 circuit packs. If LNW140 OC3/1.3/IR1 + DS1 circuit packs are installed in an Alcatel-Lucent 1665 DMXtend using pre-Release 4.0 software, equipment failures and equipment protection switching do not operate correctly.

NOTICE

Equipment damage

The LNW38, LNW40, LNW51, LNW52, LNW140, LNW302,LNW380, LNW382, and LNW601 OLIU circuit packs do not meet GR-78 R9-3 requirements on ESD susceptibility.

Always use proper ESD procedures when handling these OLIU circuit packs to avoid equipment damage.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin in this chapter.

  2. Refer to Laser safety and Electrostatic discharge information in Chapter 1, Safety.

  3. Obtain the work instructions for this procedure.

  4. Ensure that the correct OLIU circuit pack(s) is available for installation.

    The OLIU circuit packs in the Main slots must both have the same optical line rate and VT cross-connect size. If the circuit packs in the Main slots have different optical line rates or VT cross-connect sizes, the system reports an unexpected CP type alarm and service may be impacted.

    Alcatel-Lucent 1665 DMXtend supports the following high-speed OC-3/12/48/192 OLIU circuit packs:
    • LNW38: one OC-12 port (1310 nm, intermediate-reach, VT mapping across 12 STS-1 signals, OSP hardened)

    • LNW40: one OC-3 port (1310 nm, intermediate-reach, VT mapping across 6 STS-1 signals, OSP hardened)

    • LNW41: one OC-48 port SFP based (1310-nm, VT mapping across 48 STS-1 signals, OSP hardened)

    • LNW51: one OC-12 port (1310 nm, long-reach, VT mapping across 12 STS-1 signals, OSP hardened)

    • LNW52: one OC-48 port (1310 nm, long-reach, VT mapping across 12 STS-1 signals, OSP hardened) intended for use as a temporary upgrade circuit pack only

    • Very Large Fabric multirate multiport LNW84: up to eight OC-3/OC-12 ports or 2 OC-48 ports SFP based (VT mapping across 192 STS-1 signals, OSP hardened) or optics-free for headless switch applications

    • LNW140: one OC-3 port (1310 nm, intermediate-reach, VT mapping across 6 STS-1 signals, OSP hardened) and 16 DS1 ports with PM functionality

    • Very Large Fabric LNW141: one OC-192 port XFP based (1550 nm, VT mapping across 192 STS-1 signals, OSP hardened) or optics-free for headless switch applications

    • LNW302: one OC-3 port SFP based (VT mapping across 6 STS-1 signals, OSP hardened)

    • LNW380: one OC-12 port (1550 nm, long-reach, VT mapping across 12 STS-1 signals, OSP hardened)

    • LNW382: one OC-12 port SFP based (VT mapping across 12 STS-1 signals, OSP hardened)

    • LNW601: one OC-3 port (1310 nm, long-reach, VT mapping across 6 STS-1 signals, OSP hardened)

    The LNW84, LNW140 and LNW141 circuit packs are only compatible with the Alcatel-Lucent 1665 DMXtend Shelf with removable center dividers (DMXTEND-RCD-CE Shelf Type). To determine the shelf type, select View → Equipment, highlight Shelf, and click Select to obtain the shelf details.

Steps

Complete the following steps to install OLIU circuit packs in Main slots.

 
1

Ensure all optical fiber connectors and couplings are properly cleaned.

Important!

Signal performances may be degraded if the connections and couplings are not cleaned properly.

Reference:

Procedure 14-3: Clean optical fibers, dual LC adapters and LC lightguide buildouts (LBOs)


2

Important!

Pluggable transmission modules are shipped with a dust cover installed into the optical ports to maintain cleanliness during storage and/or transportation. It is recommended that the dust cover be kept in place to maintain cleanliness until the optical fiber is connected. With proper care and handling, cleaning the pluggable transmission modules should not be necessary.

If required, clean the pluggable transmission module(s).

Reference:

Procedure 14-28: Clean optical pluggable transmission module


3

Important!

The LNW84 OC3/OC12/OC48, LNW140 OC-3/DS1 and LNW141 OC-192 circuit packs are full-length circuit packs installed in the Main and Function A/B slots of the Alcatel-Lucent 1665 DMXtend Shelf with removable center dividers (DMXTEND-RCD-CE Shelf Type). The center dividers between the Main and Function A/B sections of the slots must be removed.

If...

Then...

Installing full-length LNW84, LNW140, or LNW141 circuit packs,

Remove the center dividers between the Main and Function A/B sections of the slots, if required.

Installing half-length LNW38, LNW40, LNW41, LNW51, LNW52, LNW302, LNW380, LNW382, or LNW601 circuit packs,

Install the center dividers between the Main and Function A/B sections of the slots, if required.

Reference:

Refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Installation Manual, 365-372-327, as required, when removing/installing the center dividers between the Main and Function A/B sections of the slots.


4

If required, carefully remove any caution tags that are attached to the LNW84 circuit pack.

Holding the OLIU circuit pack vertically, rotate the OLIU circuit pack 90 degrees to the right (clockwise). The faceplate label with LNW( ) should be on your right, next to the fan unit.


5

Important!

The LNW41 OC-48 OLIU circuit pack supports the circuit pack-level FAULT and ACTIVE LEDs only. The LNW41 OC-48 OLIU circuit pack does not support a port LED for the pluggable transmission module.

Open the faceplate latch(es) and seat the OLIU circuit pack in Main slot M1 by applying steady pressure to the faceplate and latch assembly.

Result:

For non-VLF OLIU circuit packs, the FAULT LED lights for approximately 20 seconds then goes off, indicating successful installation.

For VLF OLIU circuit packs, the FAULT LED lights for approximately 10 minutes then goes off, indicating successful installation.

Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation.

If response is not correct, replace the OLIU circuit pack. Refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326.


6

Secure the OLIU circuit pack in the shelf using the latch lever(s) and thumbscrew (if equipped).


7

Important!

The LNW41 OC-48 and LNW141 OC-192 OLIU circuit packs may be equipped with a pluggable transmission module. However, a pluggable transmission module is not required when the LNW141 OC-192 OLIU is used in headless, optics-free, switch applications.

The LNW302 OC-3 and LNW382 OC-12 OLIU circuit packs may be equipped with a pluggable transmission module.

The LNW84 OLIU circuit pack may be equipped with a mix of up to eight OC-3/12/48 pluggable transmission modules. However, pluggable transmission modules are not required when the LNW84 OLIU circuit pack is used in headless, optics-free, switch applications.

If required, install pluggable transmission module.

Reference:

Procedure 4-16: Install pluggable transmission modules


8

Is a second (protection) OLIU circuit pack required in Main slot M2?

If...

Then...

Yes

Continue with Step 9.

No

Insert LNW42 Application Blank or LNW95 Detectable Blank circuit pack into Main slot M2.

Proceed to Step 13.


9

If required, carefully remove any caution tags that are attached to the LNW84 circuit pack.

Holding the OLIU circuit pack vertically, rotate the OLIU circuit pack 90 degrees to the right (clockwise). The faceplate label with LNW( ) should be on your right, next to the fan unit.


10

Open the faceplate latch(es) and seat the second OLIU circuit pack in Main slot M2 by applying steady pressure to the faceplate and latch assembly.

Result:

For non-VLF OLIU circuit packs, the FAULT LED lights for approximately 20 seconds then goes off, indicating successful installation.

For VLF OLIU circuit packs, the FAULT LED lights for approximately 10 minutes then goes off, indicating successful installation.

Select View → Refresh System View and the circuit pack appears in the WaveStar® CIT System View indicating successful installation.

If response is not correct, replace the OLIU circuit pack. Refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326.


11

Secure the OLIU circuit pack in the shelf using the latch lever(s) and thumbscrew (if equipped).


12

Important!

The LNW41 OC-48 and LNW141 OC-192 OLIU circuit packs may be equipped with a pluggable transmission module. However, a pluggable transmission module is not required when the LNW141 OC-192 OLIU is used in headless, optics-free, switch applications.

The LNW302 OC-3 and LNW382 OC-12 OLIU circuit packs may be equipped with a pluggable transmission module.

The LNW84 OLIU circuit pack may be equipped with a mix of up to eight OC-3/12/48 pluggable transmission modules. However, pluggable transmission modules are not required when the LNW84 OLIU circuit pack is used in headless, optics-free, switch applications.

If required, install pluggable transmission module.

Reference:

Procedure 4-16: Install pluggable transmission modules


13

If optical port testing is...

Then...

required and has not already been performed,

Determine the optical port to be tested and continue with Step 14.

not required or has already been performed,

Proceed to Step 20.


14

Note:

If the port Signal Type parameter is STNA (Signal Type Not Available) for a port on an LNW84 multirate multiport OLIU circuit pack, then the port is not usable and cannot be tested.

Select Configuration → DCC Terminations to access the required optical port on the installed OLIU circuit pack and provision OSI over DCC as disabled to prevent DCC-related alarms. Click Apply and Close.


15

Loop back the required optical port on the installed OLIU circuit pack to test port functionality.

Reference:

Procedure 14-6: Connect OLIU optical loopbacks


16

Remove the lightguide jumper used to loop back the port and the LBO, if required.

Result:

The OLIU FAULT LED and the port LED associated with the pluggable transmission module starts flashing. The MN and NE LEDs are lighted on the SYSCTL circuit pack.


17

From the System View window, click the Alarm List button to obtain the NE Alarm List and verify that the alarm is associated with the port being tested.


18

Important!

It is recommended that the dust cover be installed into the optical ports on the pluggable transmission module to maintain cleanliness until the optical fiber is connected.

If required, reinstall the dust cover into the optical ports on the pluggable transmission module to maintain cleanliness.


19

Select Configuration → Update System → Update All to clear the incoming signal alarms.

Result:

The OLIU FAULT LED and the port LED associated with the pluggable transmission module stops flashing. All alarms are cleared.

If required, repeat Step 14 through Step 19 to test all optical ports on the OLIU circuit packs just installed.


20

From the System View window, click the Alarm List button to obtain the NE Alarm List. Verify that no alarms, protection switches, protection switch lockouts, and loopbacks are present for the ports on the OLIU circuit packs just installed.

Result:

No alarms should be present for the OLIU circuit packs just installed.


21

If required at this time, provision the circuit pack and/or port parameters.

Reference:

Procedure 4-4: Provision OLIU circuit packs/ports for service


22

If required at this time, provision the LNW84 circuit pack DS3 and DS1 port parameters.

Reference:


End of steps