Procedure 9-10.3: Establish DWDM ring network

Important!

This is not a standalone procedure. Perform this procedure only as directed by Procedure 9-10: Establish DWDM network.

Steps

Important!

This procedure assumes that the DWDM ring network is established by interconnecting Alcatel-Lucent 1665 DMXtend equipped as DWDM Add/Drop Ring nodes. However, the Alcatel-Lucent 1665 DMXtend may also be interconnected in a DWDM ring network with and Alcatel-Lucent 1665 DMX equipped as an Add/Drop Ring node.

If connecting to an Alcatel-Lucent 1665 DMXtend, refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) User Operations Guide, 365-372-325, as required, when performing this procedure.

If connecting to an Alcatel-Lucent 1665 DMX, refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) User Operations Guide, 365-372-301, as required, when performing this procedure.

Nodes are provisioned and optical spans are established individually around the ring starting with an Alcatel-Lucent 1665 DMXtend Add/Drop Ring node designated as the starting node. Continue through the ring network in the same direction until all nodes are provisioned.

This procedure assumes that all Alcatel-Lucent 1665 DMXtend shelves have been equipped with the required circuit packs for Add/Drop Ring nodes and software has been installed. If not, refer to Chapter 5, Node turnup procedures.

Ignore all alarms until the procedure is complete.

Complete the following steps to establish a DWDM ring network.

 
1

From the System View menu at an Add/Drop Ring node designated as the starting node, select Configuration → Equipment to access the OMD circuit pack in Function/Growth slot 1 and provision the OTS port parameters according to the work instructions.

Repeat this step for the companion OMD circuit pack in Function/Growth Slot 2.

Reference:

Procedure 4-25: Provision optical transport signal (OTS) port


2

Select View → Equipment to access the required OMD circuit packs and verify that the OTS ports were provisioned correctly.


3

Important!

The Optical Channel (OCH) ports of the OMD circuit packs within a Function/Growth Group are required to be pre-equipped with pass-through fiber jumpers. This minimizes the installation time of pass-through connections when a service is established. Constant travel to pass-through nodes is avoided when a service is added.

Verify that the pass-through fiber jumpers have been installed that connect the Optical Channel (OCH) ports of the OMD circuit packs in the Function/Growth Group.


4

Important!

OCH cross-connections to/from an OCH port are used to inform the network element about manual fiber connections. This allows the network element to enable alarm reporting and variable optical attenuators. The variable optical attenuators are enabled only when an OCH port is the destination of an OCH cross-connection.

Select View → OCH Cross-Connections to verify that the required pass-through OCH cross-connections exist.

If required, select Configuration → OCH Cross-Connections to access the OCH Cross-Connection Wizard and provision the required pass-through OCH cross-connections.


5

At the Add/Drop Ring node, provision the required synchronization functions (for example, timing mode) according to work instructions.

Reference:

Procedure 6-5: Network Element synchronization provisioning


6

At each Add/Drop Ring node in the ring network, provision the required OTS ports and synchronization functions according to the work instructions.

If the Add/Drop Ring node is an...

Then...

Alcatel-Lucent 1665 DMXtend,

Repeat Step 1 through Step 5 to provision the OTS ports and synchronization functions according to the work instructions.

Alcatel-Lucent 1665 DMX,

Refer to the other product's documentation to provision the required OTS ports and synchronization functions.


7

Beginning with the starting DWDM optical span, connect the optical fibers between the OTS ports and verify the integrity of the OTS line being established.

Reference:

Procedure 14-4: Perform connection and verification of optical facility


8

Perform end-to-end optical line test.

Reference:

Procedure 14-36: Perform end-to-end optical line test on DWDM line


9

Continue around the ring network until all nodes are connected.

If the node is an...

Then...

Alcatel-Lucent 1665 DMXtend,

Repeat Step 7 and Step 8 to connect and test the optical span.

Alcatel-Lucent 1665 DMX,

Refer to the other product's documentation to connect and test the optical span.


10

At each node in the ring network, click the Alarm List button and verify that no alarms are present. If required, clear any alarms that are present.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326


11

The DWDM ring network is now ready for optical channels to be added.

Reference:

Procedure 10-14: Add optical channel (OCH) to DWDM network


End of steps

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.