NOTICE Service-disruption hazard |
If a node has been taken out of the Ring Upgrade Mode, the node cannot be returned to the original pre-upgrade state without affecting service.
All nodes in the ring must be in the provisioned Ring Upgrade Mode.
Use this procedure to back out a non Very Large Fabric (VLF) OC-48 to VLF OC-192 UPSR upgrade.
Backing out of an upgrade in progress returns all nodes in the ring to their pre-upgrade state.
To temporarily stop the upgrade refer to Procedure 12-21: Suspend non-VLF OC-48 UPSR to VLF OC-192 UPSR upgrade.
Important!
Transmission hits will occur during this procedure whenever an OLIU circuit pack with a different line rate is installed or removed from a Main slot. The transmission hit is a result of an internal system timing adjustment to accommodate different line rates in the two Main slots.
You must log in as a Privileged user to complete this procedure.
The following equipment is required to perform this procedure:
Original non-VLF OC-48 OLIU circuit packs for each node to be backed out
The temporary replacement non-VLF OC-192 OLIU circuit pack is required for Main slot M2 of the starting node.
As the upgrade is backed out around the UPSR, ensure that technicians are available at each end of an optical span as the upgrade is backed out.
NOTICE Equipment damage hazard |
Rocking circuit packs back and forth when removing or installing them can damage circuit pack and/or shelf connectors.
Do not rock circuit packs back and forth when removing or installing them. Carefully slide circuit packs into or out of the shelf slot.
NOTICE Service-disruption hazard |
Removing or installing circuit packs during a System Reset can cause system errors.
Do not remove or install a circuit pack during a System Reset. If a System Reset occurs, wait until the System Reset is complete, then remove or install the circuit pack.
Prior to performing this procedure:
Refer to Laser safety and Electrostatic discharge information in Chapter 1, Safety.
Review the applicable Alcatel-Lucent 1665 Data Multiplexer (DMX) Software Release Description for any detailed procedures or cautions that may apply to this backout procedure.
Determine the local operating procedures for removing a circuit pack. Local operating procedures for removing a circuit pack may vary. One method is to disconnect the optical fibers and remove the circuit pack. Another method is to verify the circuit pack active/standby status, perform manual switches if the circuit pack is active, and then disconnect the optical fibers and remove the circuit pack.
NOTICE Service-disruption hazard |
If a node has been taken out of the Ring Upgrade Mode, the node cannot be returned to the original pre-upgrade state without affecting service.
All nodes in the ring must be in the provisioned Ring Upgrade Mode.
Important!
This procedure starts at the last node upgraded.
When optical fibers are disconnected during this procedure, inc. LOS, section DCC channel failed, and neighbor SYSCTL CP unavailable alarms are reported. The holdover mode active condition may also be reported depending on the provisioned system timing mode.
Complete the following steps to back out an non-VLF OC-48 to VLF OC-192 UPSR upgrade.
1 |
From office records and work instructions, determine the network configuration and current status of the upgrade. | ||||||
2 |
Identify the last node that was upgraded.
Reference: Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session | ||||||
3 |
If required, verify the active/standby status of the VLF OC-192 OLIU circuit pack in Main slot M2 and perform manual switches to switch traffic away from an active circuit pack. Reference: Procedure 12-20.2: Verify active/standby status of circuit pack to be replaced | ||||||
4 |
Using office records, determine the original/temporary replacement non-VLF OC-48 OLIU circuit pack types installed in the Main slots and the temporary replacement non-VLF OC-192 OLIU circuit pack installed in Main slot M2. | ||||||
5 |
Important! The VLF OC-192 OLIU circuit pack in Main slot M2 of the starting node must be replaced with the temporary replacement non-VLF OC-192 OLIU circuit pack. The temporary replacement non-VLF OC-192 OLIU circuit pack maintains traffic while the upgrade is backed out at Main slot M1 and the other nodes in the ring. As a final step, this temporary replacement non-VLF OC-192 OLIU circuit pack is backed out. Open a faceplate latch on the VLF OC-192 OLIU circuit pack in Main slot M2. Disconnect the optical fibers from the VLF OC-192 OLIU circuit pack in Main slot M2. Then replace the VLF OC-192 OLIU circuit pack in Main slot M2 with the temporary replacement non-VLF OC-192 OLIU circuit pack. Result: The system reports an unexpected CP type alarm for Main slot M2. Alarms may also be reported at other nodes in the ring. If the provisioned system timing mode is External, the system may also report an inc. DS1 sync. ref. OOL alarm. Reference: Procedure 4-2: Install OLIU circuit packs in Main slots | ||||||
6 |
Measure the optical receive power of the receive fiber using an optical power meter. Select the appropriate LBO to attenuate the receive signal to the middle of the allowable optical receive power range. Refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) Applications and Planning Guide, 365-372-300 for the SONET optical specifications of the OC-192 OLIU circuit packs. | ||||||
7 |
Clean all fiber connectors, and connect the transmit and receive optical fibers to the temporary replacement non-VLF OC-192 OLIU circuit pack in Main slot M2. Reference: Procedure 14-3: Clean optical fibers, dual LC adapters and LC lightguide buildouts (LBOs) | ||||||
8 |
Important! The UPD/INIT button does not work during this upgrade. At the System View select Configuration → Update System → Upgrade. Select main-2 as the Directed Slot Choice and click OK. Result: A dialog box appears asking you to confirm executing this command. Click Yes. The temporary replacement non-VLF OC-192 OLIU circuit pack in Main slot M2 is tested and autoprovisioned. The system performs an automatic path protection switch, and all traffic is now active on Main slot M2. Transmission hits (less than 60 ms) occur as traffic switches from the circuit pack in Main slot M1 to the circuit pack in Main slot M2. The unexpected CP type alarm for Main slot M2 clears, and the system reports an unexpected CP type alarm for Main slot M1. Alarms may also be reported at other nodes in the ring. Transmission is now supported on the optical span between Main slot M2 and the required OC-192 circuit pack/port at the opposite end of the OC-192 optical span. | ||||||
9 |
If an OC-192 OLIU circuit pack is connected to an OC-48 OLIU circuit pack equipment damage may occur. Do not reconnect the optical fibers until instructed to do so. The optical fibers are reconnected after the OC-192 OLIU circuit pack is backed out at each end of the optical span. Open the lower faceplate latch on the VLF OC-192 OLIU circuit pack in Main slot M1. Disconnect the optical fibers from the VLF OC-192 OLIU circuit pack in Main slot M1. Then replace the VLF OC-192 OLIU circuit pack in Main slot M1 with the required non-VLF OC-48 OLIU circuit pack (Series 1:6 or greater). Result: The original non-VLF OC-48 OLIU circuit pack in Main slot M1 is tested and autoprovisioned. The system reports an unexpected circuit pack type condition and an inc. OC192 LOS alarm for Main slot M1. Reference: Procedure 4-2: Install OLIU circuit packs in Main slots This completes the first phase of backing out the upgrade at the starting node. Backing out the upgrade at the starting node will be completed after backing out the upgrade at all other nodes in the ring. The following figure shows the state of the starting node and the adjacent optical spans. | ||||||
10 |
Log in to the adjacent node connected to Main slot M1. (Refer to the UPSR example at the end of the procedure.) Reference: Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session | ||||||
11 |
Back out the high-speed VLF OC-192 UPRS upgrade connections at the node to the original non-VLF OC-48 UPSR connections. Reference: Procedure 12-20.1: Back out high-speed non-VLF OC-48 to VLF OC-192 UPSR upgrade at node | ||||||
12 |
Except for the starting node, has the upgrade been backed out of all nodes in the UPSR?
| ||||||
13 |
Log in to the starting node. (Refer to the UPSR example at the end of the procedure.) Reference: Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session | ||||||
14 |
Important! The UPD/INIT button does not work during this upgrade. At the System View select Configuration → Update System → Upgrade. Select main-1 (default) as the Directed Slot Choice and click OK. Result: A dialog box appears asking you to confirm executing this command. Click Yes. The unexpected circuit pack type condition for Main slot M1 clears, and the system reports an unexpected circuit pack type condition for Main slot M2. | ||||||
15 |
If required, verify the active/standby status of the temporary replacement non-VLF OC-192 OLIU circuit pack in Main slot M2 and perform manual switches to switch traffic away from an active circuit pack. Reference: Procedure 12-20.2: Verify active/standby status of circuit pack to be replaced | ||||||
16 |
Important! If the circuit pack is active for timing and/or transmission, opening the latch causes timing and/or transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch. Open the lower faceplate latch on the temporary replacement non-VLF OC-192 OLIU circuit pack in Main slot M2. Disconnect the optical fibers from the temporary replacement non-VLF OC-192 OLIU circuit pack in Main slot M2. Then replace the temporary replacement non-VLF OC-192 OLIU circuit pack in Main slot M2 with the original non-VLF OC-48 OLIU circuit pack. Result: The unexpected circuit pack type condition for Main slot M2 clears, and the system reports an inc. OC48 LOS alarm for Main slot M2. Reference: Procedure 4-2: Install OLIU circuit packs in Main slots | ||||||
17 |
At both ends of the optical span to be backed out, perform the following to connect the original non-VLF OC-48 circuit pack in Main slot M2 and the required non-VLF OC-48 circuit pack/port at the opposite end of the original OC-48 optical span:
Result: The inc. OC48 LOS alarms clear. Transmission is now supported on the original OC-48 optical span. Reference: Procedure 14-4: Perform connection and verification of optical facility | ||||||
18 |
Important! At each node in the UPSR, the system reports the ring upgrade mode standing condition (not alarmed) in the NE Alarm List until the node is manually provisioned back to the Normal mode. At each node in the UPSR, click the Alarm List button in the top right corner of the System View to view the NE Alarm List and verify that no alarms or standing conditions are present (except ring upgrade mode and ABN condition). Refer to the appropriate trouble clearing procedures to clear all existing alarms and standing conditions (except ring upgrade mode and ABN condition) before continuing with this procedure. Reference: Alcatel-Lucent 1665 Data Multiplexer (DMX) Alarm Messages and Trouble Clearing Guide, 365-372-302 | ||||||
19 |
Important! This completes the backout procedure, except for taking the nodes out of the Ring Upgrade Mode. The decision to take the nodes out of the Ring Upgrade Mode or leave them depends on the reason the back out was necessary, and what is required before again starting the upgrade. In the Ring Upgrade Mode, UPSR cross-connections cannot be created or removed. If required at each node in the UPSR, select Configuration → Normal Mode. Result: A dialog box appears asking you to confirm changing the NE Mode to Normal mode. Click Yes. The ABN LED is turned off on the SYSCTL circuit pack faceplate and the Ring Upgrade Mode will be removed from the WaveStar® CIT alarm list. End of steps |