OPEN_FLOW
tmnxOFFlowEntryInsertFailed
Property name  | Value  | 
|---|---|
Application name  | OPEN_FLOW  | 
Event ID  | 
2001  | 
Event name  | tmnxOFFlowEntryInsertFailed  | 
SNMP notification prefix and OID  | TIMETRA-OPEN-FLOW-MIB.tmnxOpenFlowNotification.1  | 
Default severity  | minor  | 
Source stream  | 
main  | 
Message format string  | Failed to add flow-entry for open-flow switch " $tmnxOFSwitchName$" flow-table $tmnxOFFlowTableId$. Flow-table Oper Status: $tmnxOFFlowTableOperStatus$. Failure Reason $tmnxOFNotifyDescription$  | 
Cause  | The tmnxOFFlowEntryInsertFailed notification is generated when a flow-entry could not be inserted into an open-flow table.  | 
Effect  | The flow-entry won't be available in the flow-table. If inserting of a default flow-entry failed, then the value of tmnxOFFlowTableOperStatus is set to 'outOfService (3)'.  | 
Recovery  | In order to insert the failed flow-entry into flow-table is to change the admin state of an open-flow switch instance to 'outOfService (3)' and then back to 'inService (1)' and try inserting the flow-entry again.  |