CpmIcPortSFFStatusDDMCorrupt
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
4012 |
Event name | CpmIcPortSFFStatusDDMCorrupt |
SNMP notification prefix and OID | TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.7 |
Default severity | minor |
Source stream |
main |
Message format string | CPM interconnect port SFF DDM checksums do not match |
Cause | The tmnxCpmIcPortSFFStatusFailure notification is generated when the value of tmnxCpmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'. |
Effect | The SFF device is not operational and the associated CPM interconnect port cannot be used. The SFF and port will not recover without operator intervention. |
Recovery | Remove and reinsert the SFF device. If the problem persists then replace the SFF device. |
CpmIcPortSFFStatusFailure
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4011 |
Event name | CpmIcPortSFFStatusFailure |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.7 |
Default severity |
minor |
Source stream | main |
Message format string | CPM interconnect port SFF checksums do not match |
Cause | The tmnxCpmIcPortSFFStatusFailure notification is generated when the value of tmnxCpmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'. |
Effect | The SFF device is not operational and the associated CPM interconnect port cannot be used. The SFF and port will not recover without operator intervention. |
Recovery | Remove and reinsert the SFF device. If the problem persists then replace the SFF device. |
CpmIcPortSFFStatusReadError
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4013 |
Event name | CpmIcPortSFFStatusReadError |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.7 |
Default severity |
minor |
Source stream | main |
Message format string | CPM interconnect port SFF read failure |
Cause | The tmnxCpmIcPortSFFStatusFailure notification is generated when the value of tmnxCpmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'. |
Effect | The SFF device is not operational and the associated CPM interconnect port cannot be used. The SFF and port will not recover without operator intervention. |
Recovery | Remove and reinsert the SFF device. If the problem persists then replace the SFF device. |
CpmIcPortSFFStatusUnsupported
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4014 |
Event name | CpmIcPortSFFStatusUnsupported |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.7 |
Default severity |
minor |
Source stream | main |
Message format string | CPM interconnect port SFF unsupported type |
Cause | The tmnxCpmIcPortSFFStatusFailure notification is generated when the value of tmnxCpmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'. |
Effect | The SFF device is not operational and the associated CPM interconnect port cannot be used. The SFF and port will not recover without operator intervention. |
Recovery | Remove and reinsert the SFF device. If the problem persists then replace the SFF device. |
SfmIcPortSFFStatusDDMCorrupt
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4022 |
Event name | SfmIcPortSFFStatusDDMCorrupt |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.5 |
Default severity |
minor |
Source stream | main |
Message format string | SFM interconnect port SFF DDM checksums do not match |
Cause | The tmnxSfmIcPortSFFStatusFailure notification is generated when the value of tmnxSfmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'. |
Effect | The SFF device is not operational and the associated SFM interconnect port cannot be used. The SFF and port will not recover without operator intervention. |
Recovery | Remove and reinsert the SFF device. If the problem persists then replace the SFF device. |
SfmIcPortSFFStatusFailure
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4021 |
Event name | SfmIcPortSFFStatusFailure |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.5 |
Default severity |
minor |
Source stream | main |
Message format string | SFM interconnect port SFF checksums do not match |
Cause | The tmnxSfmIcPortSFFStatusFailure notification is generated when the value of tmnxSfmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'. |
Effect | The SFF device is not operational and the associated SFM interconnect port cannot be used. The SFF and port will not recover without operator intervention. |
Recovery | Remove and reinsert the SFF device. If the problem persists then replace the SFF device. |
SfmIcPortSFFStatusReadError
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4023 |
Event name | SfmIcPortSFFStatusReadError |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.5 |
Default severity |
minor |
Source stream | main |
Message format string | SFM interconnect port SFF read failure |
Cause | The tmnxSfmIcPortSFFStatusFailure notification is generated when the value of tmnxSfmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'. |
Effect | The SFF device is not operational and the associated SFM interconnect port cannot be used. The SFF and port will not recover without operator intervention. |
Recovery | Remove and reinsert the SFF device. If the problem persists then replace the SFF device. |
SfmIcPortSFFStatusUnsupported
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4024 |
Event name | SfmIcPortSFFStatusUnsupported |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.5 |
Default severity |
minor |
Source stream | main |
Message format string | SFM interconnect port SFF unsupported type |
Cause | The tmnxSfmIcPortSFFStatusFailure notification is generated when the value of tmnxSfmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'. |
Effect | The SFF device is not operational and the associated SFM interconnect port cannot be used. The SFF and port will not recover without operator intervention. |
Recovery | Remove and reinsert the SFF device. If the problem persists then replace the SFF device. |
tChassisAirflowDirMismatch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2233 |
Event name | tChassisAirflowDirMismatch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.244 |
Default severity |
critical |
Source stream | main |
Message format string | $tmnxHwClass$ $tmnxChassisNotifyHwIndex$: airflow direction mismatch |
Cause | The tChassisAirflowDirMismatch notification is generated when airflow direction is not identical for all chassis fans and power-supply fans equipped by the physical chassis. |
Effect | Mismatched airflow direction among fans may cause increased temperature, intermittent errors, and could damage components. |
Recovery | The operator must identify a single preferred airflow direction, remove any chassis fans and power-supply fans which do not match it, and replace them with equipment having fans of the preferred airflow direction. |
tChassisAirflowDirMismatchClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2234 |
Event name | tChassisAirflowDirMismatchClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.245 |
Default severity |
critical |
Source stream | main |
Message format string | $tmnxHwClass$ $tmnxChassisNotifyHwIndex$: airflow direction mismatch cleared |
Cause | The tChassisAirflowDirMismatchClr notification is generated to indicate that all chassis fans and power-supply fans with mismatched airflow directions have been replaced, and all chassis-fans and power-supply fans share the same direction. |
Effect | N/A |
Recovery | N/A |
tChassisPowerSupplyMismatch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2235 |
Event name | tChassisPowerSupplyMismatch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.246 |
Default severity |
critical |
Source stream | main |
Message format string | $tmnxHwClass$ $tmnxChassisNotifyHwIndex$: power-supply type mismatch |
Cause | The tChassisPowerSupplyMismatch notification is generated when power-supply elements equipped to the physical chassis are not all of the same type. |
Effect | There is an increased risk of power-supply failure. Intermittent error or damage to components may also result. |
Recovery | The operator must identify a single preferred or required power-supply type, remove any power-supply elements of other types, and replace them with equipment of the preferred power-supply type. |
tChassisPowerSupplyMismatchClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2236 |
Event name | tChassisPowerSupplyMismatchClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.247 |
Default severity |
critical |
Source stream | main |
Message format string | $tmnxHwClass$ $tmnxChassisNotifyHwIndex$: power-supply type mismatch cleared |
Cause | The tChassisPowerSupplyMismatchClr notification is generated to indicate that all power-supply elements of mismatched types have been replaced, and all power-supply elements now share the same type. |
Effect | N/A |
Recovery | N/A |
tChassisPowerSupplyUnsup
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2237 |
Event name | tChassisPowerSupplyUnsup |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.248 |
Default severity |
critical |
Source stream | main |
Message format string | $tmnxChassisNotifyHwIndex$: power-supply not supported |
Cause | The tChassisPowerSupplyUnsup notification is generated when power-supply elements equipped to the physical chassis are not of a supported type. |
Effect | There is an increased risk of power-supply failure. Intermittent error or damage to components may also result. |
Recovery | The operator must identify any equipped power supply elements of unsupported type, remove them, and replace them with equipment of a supported power-supply type |
tIPsecEsaVmMemHighWatermark
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2220 |
Event name | tIPsecEsaVmMemHighWatermark |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.231 |
Default severity |
minor |
Source stream | main |
Message format string | The memory usage ratio for ESA-VM $tmnxEsaNotifyId$/$tmnxEsaVmNotifyId$ has almost reached the maximum value. |
Cause | A tIPsecEsaVmMemHighWatermark notification is generated when the ESA VM memory usage ratio has almost reached the maximum value. |
Effect | The system may stop accepting new IKE states shortly. |
Recovery | Use fewer SAs for each IKE tunnel. |
tIPsecEsaVmMemLowWatermark
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2219 |
Event name | tIPsecEsaVmMemLowWatermark |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.230 |
Default severity |
minor |
Source stream | main |
Message format string | The memory usage ratio for ESA-VM $tmnxEsaNotifyId$/$tmnxEsaVmNotifyId$ has dropped back to the normal level. |
Cause | A tIPsecEsaVmMemLowWatermark notification is generated when the ESA VM memory usage ratio has dropped back to the normal level. |
Effect | The system accepts new IKE states. |
Recovery |
There is no recovery required for this notification. |
tIPsecIsaMemHighWatermark
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2151 |
Event name | tIPsecIsaMemHighWatermark |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.138 |
Default severity |
minor |
Source stream | main |
Message format string | The memory usage ratio for ISA $tmnxCardSlotNum$/$tmnxMDASlotNum$ has almost reached the maximum value. |
Cause | A tIPsecIsaMemHighWatermark notification is generated when the ISA card memory usage ratio has almost reached the maximum value. |
Effect | The system may stop accepting new IKE states shortly. |
Recovery | Use fewer SAs for each IKE tunnel. |
tIPsecIsaMemLowWatermark
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2150 |
Event name | tIPsecIsaMemLowWatermark |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.137 |
Default severity |
minor |
Source stream | main |
Message format string | The memory usage ratio for ISA $tmnxCardSlotNum$/$tmnxMDASlotNum$ has dropped back to the normal level. |
Cause | A tIPsecIsaMemLowWatermark notification is generated when the ISA card memory usage ratio has dropped back to the normal level. |
Effect | The system accepts new IKE states. |
Recovery |
There is no recovery required for this notification. |
tIPsecIsaMemMax
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2152 |
Event name | tIPsecIsaMemMax |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.139 |
Default severity | minor |
Source stream |
main |
Message format string | The memory usage for ISA $tmnxCardSlotNum$/$tmnxMDASlotNum$ has reached the maximum value. |
Cause |
A tIPsecIsaMemMax notification is generated when the ISA card memory usage ratio has reached the maximum value. |
Effect | The system stops accepting new IKE states. |
Recovery | Use fewer SAs for each IKE tunnel. |
tmnxAlarmInputVoltageFailure
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3014 |
Event name | tmnxAlarmInputVoltageFailure |
SNMP notification prefix and OID |
TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSASChassisNotification.10 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : alarm input voltage failure |
Cause | A tmnxAlarmInputVoltageFailure notification is sent when the internal power supply for alarm inputs fails. The value of tmnxSasAlarmInputPowerStatus indicates whether the power to external alarm inputs is on or off. |
Effect | If the alarm inputs use the internal power supply, then a failure in the power supply will cause state change event alarms to not be raised. |
Recovery | Check the internal power source for alarm inputs and rectify the problem. |
tmnxBluetoothModuleConnectionChg
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2187 |
Event name | tmnxBluetoothModuleConnectionChg |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.178 |
Default severity |
minor |
Source stream | main |
Message format string | Bluetooth Module $tmnxChassisNotifyCpmCardSlotNum$ got $tmnxBluetoothModuleConnected$ to $tmnxBluetoothModuleConnectedMac$. |
Cause | The tmnxBluetoothModuleConnectionChg notification is generated when a remote Bluetooth device connects with or disconnects from the indicated Bluetooth module. |
Effect | A Bluetooth device has connected with or disconnected from a Bluetooth module. |
Recovery | No recovery required. |
tmnxCardResMacFdbHighUsgClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 5164 |
Event name | tmnxCardResMacFdbHighUsgClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.149 |
Default severity |
minor |
Source stream | main |
Message format string | The FDB table usage for card $tmnxMacScaleCardSlotNum$ is below 90% of the card limit |
Cause | The tmnxCardResMacFdbHighUsgClr notification is generated when the FDB table size drops below 90% of the card limit. |
Effect | The FDB table size for the card drops below 90% of the card limit. |
Recovery | None needed. |
tmnxCardResMacFdbHighUsgSet
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 5163 |
Event name | tmnxCardResMacFdbHighUsgSet |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.148 |
Default severity |
minor |
Source stream | main |
Message format string | The FDB table usage for card $tmnxMacScaleCardSlotNum$ is above 95% of the card limit |
Cause | The tmnxCardResMacFdbHighUsgSet notification is generated when the FDB table size exceeds 95% of the card limit. |
Effect | The FDB table size for the card exceeds 95% of the card limit. |
Recovery | None needed. |
tmnxChassisHiBwMcastAlarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2052 |
Event name | tmnxChassisHiBwMcastAlarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.43 |
Default severity |
minor |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Plane shared by multiple multicast high bandwidth taps |
Cause | The tmnxChassisHiBwMcastAlarm notification is generated when a plane is shared by more than one high bandwidth multicast tap. |
Effect | N/A |
Recovery | N/A |
tmnxChassisNotificationClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2016 |
Event name | tmnxChassisNotificationClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.25 |
Default severity |
major |
Source stream | main |
Message format string | Clear $tmnxHwClass$ $tmnxHwIndex$ $tmnxChassisNotifyOID$ |
Cause | A trap indicating the clear of a chassis notification identified by tmnxChassisNotifyOID. |
Effect | N/A |
Recovery | N/A |
tmnxChassisUpgradeComplete
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2034 |
Event name | tmnxChassisUpgradeComplete |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.42 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : software upgrade complete |
Cause | The tmnxChassisUpgradeComplete notification is generated to indicate that all the IOMs are running matching software versions in reference to the active CPM software version changed as part of the upgrade process. |
Effect | N/A |
Recovery | N/A |
tmnxChassisUpgradeInProgress
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2033 |
Event name | tmnxChassisUpgradeInProgress |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.41 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : software upgrade in progress |
Cause | The tmnxChassisUpgradeInProgress notification is generated only after a CPM switchover occurs and the new active CPM is running new software, while the IOMs or XCMs are still running old software. This is the start of the upgrade process. The tmnxChassisUpgradeInProgress notification will continue to be generated every 30 minutes while at least one IOM is still running older software. |
Effect | A software mismatch between the CPM and IOM or XCM is generally fine for a short duration (during an upgrade) but may not allow for correct long-term operation. |
Recovery | Complete the upgrade of all IOMs or XCMs. |
tmnxCpmALocalIcPortAvail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4009 |
Event name | tmnxCpmALocalIcPortAvail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.6 |
Default severity |
major |
Source stream | main |
Message format string | CPM $tmnxChassisNotifyCpmCardSlotNum$ can reach the chassis using its local CPM interconnect ports |
Cause | The tmnxCpmLocalIcPortAvail notification is generated when the CPM re-establishes communication with the other chassis using its local CPM interconnect ports. |
Effect | A new control communications path is now available between the CPM and the other chassis. |
Recovery | N/A |
tmnxCpmANoLocalIcPort
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
4007 |
Event name | tmnxCpmANoLocalIcPort |
SNMP notification prefix and OID | TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.5 |
Default severity | major |
Source stream |
main |
Message format string | CPM $tmnxChassisNotifyCpmCardSlotNum$ can not reach the chassis using its local CPM interconnect ports |
Cause | The tmnxCpmNoLocalIcPort alarm is generated when the CPM cannot reach the other chassis using its local CPM interconnect ports. |
Effect | Another control communications path may still be available between the CPM and the other chassis via the mate CPM in the same chassis. If that alternative path is not available then complete disruption of control communications to the other chassis will occur and the tmnxInterChassisCommsDown alarm is raised. A tmnxCpmNoLocalIcPort alarm on the active CPM indicates that a further failure of the local CPM interconnect ports on the standby CPM will cause complete disruption of control communications to the other chassis and the tmnxInterChassisCommsDown alarm is raised. A tmnxCpmNoLocalIcPort alarm on the standby CPM indicates that a CPM switchover may cause temporary disruption of control communications to the other chassis while the rebooting CPM comes back into service. |
Recovery | Ensure that all CPM interconnect ports in the system are properly cabled together with working cables. |
tmnxCpmBLocalIcPortAvail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4010 |
Event name | tmnxCpmBLocalIcPortAvail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.6 |
Default severity |
major |
Source stream | main |
Message format string | CPM $tmnxChassisNotifyCpmCardSlotNum$ can reach the chassis using its local CPM interconnect ports |
Cause | The tmnxCpmLocalIcPortAvail notification is generated when the CPM re-establishes communication with the other chassis using its local CPM interconnect ports. |
Effect | A new control communications path is now available between the CPM and the other chassis. |
Recovery | N/A |
tmnxCpmBNoLocalIcPort
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
4008 |
Event name | tmnxCpmBNoLocalIcPort |
SNMP notification prefix and OID | TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.5 |
Default severity | major |
Source stream |
main |
Message format string | CPM $tmnxChassisNotifyCpmCardSlotNum$ can not reach the chassis using its local CPM interconnect ports |
Cause | The tmnxCpmNoLocalIcPort alarm is generated when the CPM cannot reach the other chassis using its local CPM interconnect ports. |
Effect | Another control communications path may still be available between the CPM and the other chassis via the mate CPM in the same chassis. If that alternative path is not available then complete disruption of control communications to the other chassis will occur and the tmnxInterChassisCommsDown alarm is raised. A tmnxCpmNoLocalIcPort alarm on the active CPM indicates that a further failure of the local CPM interconnect ports on the standby CPM will cause complete disruption of control communications to the other chassis and the tmnxInterChassisCommsDown alarm is raised. A tmnxCpmNoLocalIcPort alarm on the standby CPM indicates that a CPM switchover may cause temporary disruption of control communications to the other chassis while the rebooting CPM comes back into service. |
Recovery | Ensure that all CPM interconnect ports in the system are properly cabled together with working cables. |
tmnxCpmCardSyncFileNotPresent
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2057 |
Event name | tmnxCpmCardSyncFileNotPresent |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.45 |
Default severity |
minor |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Optional file $tmnxChassisNotifyCardSyncFile$ is not present during sync operation |
Cause | The tmnxCpmCardSyncFileNotPresent notification is generated when the redundancy file synchronization failed to locate an optional file. |
Effect | N/A |
Recovery | N/A |
tmnxCpmIcPortDDMClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4016 |
Event name | tmnxCpmIcPortDDMClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.9 |
Default severity |
minor |
Source stream | main |
Message format string | CPM interconnect port SFF DDM $tmnxDDMLaneIdOrModule$ ($tmnxDDMFailedObject$) cleared |
Cause | The tmnxCpmIcPortDDMFailure notification is generated when an SFF in a CPM interconnect port that supports Digital Diagnostic Monitoring (DDM) clears a failed state. |
Effect | N/A |
Recovery | N/A |
tmnxCpmIcPortDDMFailure
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4015 |
Event name | tmnxCpmIcPortDDMFailure |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.8 |
Default severity |
minor |
Source stream | main |
Message format string | CPM interconnect port SFF DDM $tmnxDDMLaneIdOrModule$ ($tmnxDDMFailedObject$) raised |
Cause | The tmnxCpmIcPortDDMFailure notification is generated when an SFF in a CPM interconnect port that supports Digital Diagnostic Monitoring (DDM) enters a failed state. |
Effect | N/A |
Recovery | N/A |
tmnxCpmIcPortDown
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4003 |
Event name | tmnxCpmIcPortDown |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.1 |
Default severity |
minor |
Source stream | main |
Message format string | CPM interconnect port is not operational. Error code = $tmnxCpmIcPortOperState$ |
Cause | The tmnxCpmIcPortDown alarm is generated when the CPM interconnect port is not operational. The reason may be a cable connected incorrectly, a disconnected cable, a faulty cable, or a misbehaving CPM interconnect port or card. |
Effect | At least one of the control plane paths used for inter-chassis CPM communication is not operational. Other paths may be available. |
Recovery | A manual verification and testing of each CPM interconnect port is required to ensure fully functional operation. Physical replacement of cabling may be required. |
tmnxCpmIcPortSFFInserted
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4005 |
Event name | tmnxCpmIcPortSFFInserted |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.3 |
Default severity |
minor |
Source stream | main |
Message format string | CPM interconnect port SFF inserted |
Cause |
The tmnxCpmIcPortSFFInserted notification is generated when the small form factor (SFF) pluggable optical module (eg. QSFP) is inserted into a CPM interconnect port. |
Effect | This event is for notification only. |
Recovery |
N/A |
tmnxCpmIcPortSFFRemoved
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
4006 |
Event name | tmnxCpmIcPortSFFRemoved |
SNMP notification prefix and OID | TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.4 |
Default severity | minor |
Source stream |
main |
Message format string | CPM interconnect port SFF removed |
Cause | The tmnxCpmIcPortSFFRemoved notification is generated when the SFF (eg. QSFP) is removed from the CPM interconnect port. Removing an SFF causes both this trap, and also a tmnxCpmIcPortDown event. |
Effect | Removing the SFF will cause the CPM interconnect port to go down. This port will no longer be able to be used as part of the control plane between chassis but other paths may be available. |
Recovery | Insert a working SFF into the port. |
tmnxCpmIcPortUp
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
4004 |
Event name | tmnxCpmIcPortUp |
SNMP notification prefix and OID | TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.2 |
Default severity | minor |
Source stream |
main |
Message format string | CPM interconnect port is operational |
Cause | The tmnxCpmIcPortUp notification is generated when the CPM interconnect port is operational again. |
Effect | A control plane communication path between CPM cards in the different chassis have been established. |
Recovery | N/A |
tmnxCpmMemSizeMismatch
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2153 |
Event name | tmnxCpmMemSizeMismatch |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.140 |
Default severity | major |
Source stream |
main |
Message format string | The standby CPM $tmnxChassisNotifyCpmCardSlotNum$ has a different memory size than the active $tmnxChassisNotifyHwIndex$ |
Cause | A tmnxCpmMemSizeMismatch notification is generated when the RAM memory size of the standby CPM (i.e., tmnxChassisNotifyCpmCardSlotNum) is different than the active CPM (i.e., tmnxChassisNotifyHwIndex). |
Effect | There is an increased risk of the memory overflow on the standby CPM during the CPM switchover. |
Recovery | Use CPMs with the same memory size. |
tmnxCpmMemSizeMismatchClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2154 |
Event name | tmnxCpmMemSizeMismatchClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.141 |
Default severity |
cleared |
Source stream | main |
Message format string | The standby CPM $tmnxChassisNotifyCpmCardSlotNum$ has the same memory size as the active $tmnxChassisNotifyHwIndex$ |
Cause | A tmnxCpmMemSizeMismatchClear notification is generated when the RAM memory sizes of the standby (i.e., tmnxChassisNotifyCpmCardSlotNum) and active (i.e., tmnxChassisNotifyHwIndex) CPMs become matched. |
Effect | The tmnxCpmMemSizeMismatch notification is cleared. |
Recovery | There is no recovery required for this notification. |
tmnxDcpCardFpEventOvrflw
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2084 |
Event name | tmnxDcpCardFpEventOvrflw |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.72 |
Default severity |
minor |
Source stream | main |
Message format string | TODO |
Cause | The tmnxDcpCardFpEventOvrflw notification is generated when a flood of distributed CPU FP protection events occur on a particular card and some of the events are lost due to event throttling mechanism. |
Effect | Some FP notifications configured on the card may not be received. |
Recovery | Notifications will resume once the event throttling ends. |
tmnxDcpCardFpEventOvrflwClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2089 |
Event name | tmnxDcpCardFpEventOvrflwClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.77 |
Default severity |
minor |
Source stream | main |
Message format string | TODO |
Cause | The tmnxDcpCardFpEventOvrflwClr notification is generated when the event throttling has ended for distributed CPU protection FP events on a particular card. |
Effect | Notifications are received again since the event throttling has ended. |
Recovery | There is no recovery for this notification. |
tmnxDcpCardSapEventOvrflw
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2085 |
Event name | tmnxDcpCardSapEventOvrflw |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.73 |
Default severity |
minor |
Source stream | main |
Message format string | TODO |
Cause | The tmnxDcpCardSapEventOvrflw notification is generated when a flood of distributed CPU protection SAP events occur on a particular card and some of the events are lost due to event throttling mechanism. |
Effect | Some SAP notifications configured on the card may not be received. |
Recovery | Notifications will resume once the event throttling ends. |
tmnxDcpCardSapEventOvrflwClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2090 |
Event name | tmnxDcpCardSapEventOvrflwClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.78 |
Default severity |
minor |
Source stream | main |
Message format string | TODO |
Cause | The tmnxDcpCardSapEventOvrflwClr notification is generated when the event throttling has ended for distributed CPU protection SAP events on a particular card. |
Effect | Notifications are received again since the event throttling has ended. |
Recovery | There is no recovery for this notification. |
tmnxDcpCardVrtrIfEventOvrflw
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2086 |
Event name | tmnxDcpCardVrtrIfEventOvrflw |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.74 |
Default severity |
minor |
Source stream | main |
Message format string | TODO |
Cause | The tmnxDcpCardVrtrIfEventOvrflw notification is generated when a flood of distributed CPU protection network-interface events occur on a particular card and some of the events are lost due to event throttling mechanism. |
Effect | Some network-interface notifications configured on the card may not be received. |
Recovery | Notifications will resume once the event throttling ends. |
tmnxDcpCardVrtrIfEventOvrflwClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2091 |
Event name | tmnxDcpCardVrtrIfEventOvrflwClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.79 |
Default severity |
minor |
Source stream | main |
Message format string | TODO |
Cause | The tmnxDcpCardVrtrIfEventOvrflwClr notification is generated when the event throttling has ended for distributed CPU protection network-interface events on a particular card. |
Effect | Notifications are received again since the event throttling has ended. |
Recovery | There is no recovery for this notification. |
tmnxDcpFpDynPoolUsageHiAlmClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2088 |
Event name | tmnxDcpFpDynPoolUsageHiAlmClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.76 |
Default severity |
minor |
Source stream | main |
Message format string | TODO |
Cause | The tmnxDcpFpDynPoolUsageHiAlmClear notification is generated when the dynamic enforcement policer pool usage on the forwarding plane is no longer exhausted. |
Effect | Dynamic enforcement policers are available in the free pool to be allocated when needed. |
Recovery | There is no recovery required for this notification. |
tmnxDcpFpDynPoolUsageHiAlmRaise
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2087 |
Event name | tmnxDcpFpDynPoolUsageHiAlmRaise |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.75 |
Default severity |
minor |
Source stream | main |
Message format string | TODO |
Cause | The tmnxDcpFpDynPoolUsageHiAlmRaise notification is generated when the dynamic enforcement policer pool usage on the forwarding plane is nearly exhausted. |
Effect | Dynamic enforcement policers may not get allocated on the forwarding plane. |
Recovery | This notification will be cleared when either the dynamic enforcement policer pool is increased or the usage drops. |
tmnxEnvTempTooHigh
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2005 |
Event name | tmnxEnvTempTooHigh |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.2 |
Default severity |
major |
Source stream | main |
Message format string | $tmnxHwClass$ $tmnxChassisNotifyHwIndex$: temperature too high |
Cause | Generated when the temperature sensor reading on an equipment object is greater than its configured threshold. |
Effect | This could be causing intermittent errors and could also cause permanent damage to components. |
Recovery | Remove or power down the affected cards, or improve the cooling to the node. More powerful fan trays may also be required. |
tmnxEqBpEpromFail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2161 |
Event name | tmnxEqBpEpromFail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.150 |
Default severity |
critical |
Source stream | main |
Message format string | CPM BP EPROM could not be accessed |
Cause | The tmnxEqBpEpromFail notification is generated when the active CPM is no longer able to access the backplane EPROM due to a hardware defect. |
Effect | The active CPM is at risk of failing to initialize after node reboot due to not being able to access the BP EPROM to read the chassis type. |
Recovery | Contact Nokia customer support. |
tmnxEqBpEpromFailClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2162 |
Event name | tmnxEqBpEpromFailClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.151 |
Default severity |
cleared |
Source stream | main |
Message format string | CPM BP EPROM can now be accessed |
Cause | The tmnxEqBpEpromFailClear notification is generated when the EPROM error condition is cleared. |
Effect | N/A |
Recovery | N/A |
tmnxEqBpEpromWarning
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2163 |
Event name | tmnxEqBpEpromWarning |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.152 |
Default severity |
minor |
Source stream | main |
Message format string | One CPM BP EPROM could not be accessed |
Cause | The tmnxEqBpEpromWarning notification is generated when the active CPM is no longer able to access one backplane EPROM due to a hardware defect, but a redundant EPROM is present and accessible. |
Effect | There is no effect on system operation. |
Recovery | No recovery action required. |
tmnxEqBpEpromWarningClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2164 |
Event name | tmnxEqBpEpromWarningClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.153 |
Default severity |
cleared |
Source stream | main |
Message format string | All CPM BP EPROMs can be accessed |
Cause | The tmnxEqBpEpromWarningClear notification is generated when the backplane EPROM warning condition is cleared. |
Effect | N/A |
Recovery | N/A |
tmnxEqCardChipIfCellEvent
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2103 |
Event name | tmnxEqCardChipIfCellEvent |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.90 |
Default severity |
minor |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxEqCardChipIfCellEvent notification is generated when an inter-chip interface (XPL2 bundle) experiences internal datapath cell errors. |
Effect | Contact Nokia customer support. |
Recovery |
Contact Nokia customer support. |
tmnxEqCardChipIfDownEvent
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2102 |
Event name | tmnxEqCardChipIfDownEvent |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.89 |
Default severity | minor |
Source stream |
main |
Message format string | Possible messages:
|
Cause | The tmnxEqCardChipIfDownEvent notification is generated when an inter-chip interface (XPL2 bundle) experiences an internal datapath problem. |
Effect | 7750 SR/7450 ESS: The IOM or IMM will either remain operational or the card will reset along with its associated MDAs. 7950 XRS: The associated XMA (MDA CLI context) will either remain operational or it will reset. The XCM (CLI card context) will not reset. |
Recovery | Contact Nokia customer support. |
tmnxEqCardFailure
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2001 |
Event name | tmnxEqCardFailure |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.7 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : failed, reason: $tmnxChassisNotifyCardFailureReason$ |
Cause | Generated when one of the cards in a chassis has failed. The card type may be IOM (or XCM), MDA (or XMA), SFM, CCM, CPM, Compact Flash, etc. The reason is indicated in the details of the log event or alarm, and also available in the tmnxChassisNotifyCardFailureReason attribute included in the SNMP notification. |
Effect | The effect is dependent on the card that has failed. IOM (or XCM) or MDA (or XMA) failure will cause a loss of service for all services running on that card. A fabric failure can impact traffic to/from all cards. 7750 SR/7450 ESS - If the IOM/IMM fails then the two associated MDAs for the slot will also go down. 7950 XRS - If one out of two XMAs fails in a XCM slot then the XCM will remain up. If only one remaining operational XMA within a XCM slot fails, then the XCM will go into a booting operational state. |
Recovery | Before taking any recovery steps, collect a tech-support file, then try resetting (clear) the card. If that doesn't work then try removing and then reinserting the card. If that doesn't work then replace the card. |
tmnxEqCardFirmwareUpgraded
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2032 |
Event name | tmnxEqCardFirmwareUpgraded |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.40 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : firmware upgraded |
Cause | Generated when a card is hot-inserted into the chassis and its firmware is automatically upgraded. The card type may be IOM or CPM module. |
Effect | N/A |
Recovery | N/A |
tmnxEqCardInserted
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2002 |
Event name | tmnxEqCardInserted |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.8 |
Default severity |
minor |
Source stream | main |
Message format string | Class $tmnxHwClass$ : inserted |
Cause | Generated when a card is inserted into the chassis. The card type may be IOM, Fabric, MDA, MCM, CCM CPM module, compact flash module, etc. |
Effect | N/A |
Recovery | N/A |
tmnxEqCardMissing
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 6007 |
Event name | tmnxEqCardMissing |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.303 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : missing |
Cause | The tmnxEqCardMissing notification is generated when the card configuration is present but the card is not detected in the slot. |
Effect | The missing card will cause a loss of service for all services running on that card. |
Recovery | Before taking any recovery steps collect a tech-support file, then try inserting a compatible card into the slot. |
tmnxEqCardMissingClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 6008 |
Event name | tmnxEqCardMissingClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.304 |
Default severity |
cleared |
Source stream | main |
Message format string | Class $tmnxHwClass$ : missing clear |
Cause | The tmnxEqCardMissingClear notification is generated when the card configuration is removed or the card is detected in the slot. |
Effect | N/A |
Recovery | N/A |
tmnxEqCardPChipCamEvent
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2076 |
Event name | tmnxEqCardPChipCamEvent |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.64 |
Default severity |
critical |
Source stream | main |
Message format string | A fault has been detected in the hardware on IOM $tmnxSlotNum$-forwarding engine $tmnxCardComplexNumber$ |
Cause | The tmnxEqCardPChipCamEvent notification is generated when either an IOM or a CPM experiences a persistent occurrence of a PChip CAM error. On a CPM card, the tmnxCardComplexNumber will be fixed to the value zero (0). |
Effect | Contact Nokia customer support. |
Recovery |
Contact Nokia customer support. |
tmnxEqCardPChipError
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2059 |
Event name | tmnxEqCardPChipError |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.47 |
Default severity | minor |
Source stream |
main |
Message format string | Slot $tmnxCardSlotNum$ detected $tmnxCardFwdDirection$ FCS errors on complex $tmnxCardComplexNumber$. Source card(s) of detected errors: $tmnxCardSrcSlotBitmap$ |
Cause | The tmnxEqCardPChipError notification is generated when persistent FCS errors are detected by the P chip in either the ingress or egress datapath/complex. The value tmnxCardSrcSlotBitmap is only used for the egress datapath/complex direction. |
Effect | N/A |
Recovery | N/A |
tmnxEqCardPChipMemoryEvent
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2063 |
Event name | tmnxEqCardPChipMemoryEvent |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.51 |
Default severity |
minor |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxEqCardPChipMemoryEvent notification is generated when a P-chip experiences an occurrence of a memory error. |
Effect | N/A |
Recovery | N/A |
tmnxEqCardQChipBufMemoryEvent
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2098 |
Event name | tmnxEqCardQChipBufMemoryEvent |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.86 |
Default severity |
minor |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxEqCardQChipBufMemoryEvent notification is generated when a Q-chip experiences an occurrence of a buffer memory error. |
Effect | Contact Nokia customer support. |
Recovery |
Contact Nokia customer support. |
tmnxEqCardQChipIntMemoryEvent
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2101 |
Event name | tmnxEqCardQChipIntMemoryEvent |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.88 |
Default severity |
minor |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxEqCardQChipIntMemoryEvent notification is generated when a Q-chip experiences an occurrence of an internal memory error. |
Effect | Contact Nokia customer support. |
Recovery |
Contact Nokia customer support. |
tmnxEqCardQChipStatsMemoryEvent
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2099 |
Event name | tmnxEqCardQChipStatsMemoryEvent |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.87 |
Default severity |
minor |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxEqCardQChipStatsMemoryEvent notification is generated when a Q-chip experiences an occurrence of a statistics memory error. |
Effect | Contact Nokia customer support. |
Recovery |
Contact Nokia customer support. |
tmnxEqCardRemoved
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2003 |
Event name | tmnxEqCardRemoved |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.9 |
Default severity | major |
Source stream |
main |
Message format string | Class $tmnxHwClass$ : removed |
Cause | Generated when a card is removed from the chassis. The card type may be IOM (or XCM), MDA (or XMA), SFM, CCM, CPM, Compact Flash, etc. |
Effect | The effect is dependent on the card that has been removed. IOM (or XCM) or MDA (or XMA) removal will cause a loss of service for all services running on that card. A fabric removal can impact traffic to/from all cards. |
Recovery | Before taking any recovery steps collect a tech-support file, then try reinserting the card. If that doesn't work then replace the card. |
tmnxEqCardSoftResetAlarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2060 |
Event name | tmnxEqCardSoftResetAlarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.48 |
Default severity |
minor |
Source stream | main |
Message format string | Slot $tmnxHwIndex$ entered soft-reset state $tmnxCardSoftResetState$ |
Cause | The tmnxEqCardSoftResetAlarm notification is generated when an IOM card enters and exits the 'soft-reset' state. |
Effect | N/A |
Recovery | N/A |
tmnxEqCardTChipParityEvent
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2110 |
Event name | tmnxEqCardTChipParityEvent |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.97 |
Default severity |
minor |
Source stream | main |
Message format string | Slot $tmnxHwIndex$ experienced a T-chip memory error occurrence on complex $tmnxCardComplexNumber$ |
Cause | The tmnxEqCardTChipParityEvent notification is generated when a T-chip experiences an occurrence of an internal memory error. |
Effect | Contact Nokia customer support. |
Recovery |
Contact Nokia customer support. |
tmnxEqDataPathFailureProtImpact
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2126 |
Event name | tmnxEqDataPathFailureProtImpact |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.113 |
Default severity |
minor |
Source stream | main |
Message format string | $tmnxHwClass$ $tmnxHwIndex$ experienced a datapath failure which impacted a protocol. |
Cause | The tmnxEqDataPathFailureProtImpact notification is generated when a slot experienced a data path failure which impacted a protocol. |
Effect | Services-related data associated with the impacted protocol may be lost. |
Recovery | N/A |
tmnxEqFlashDataLoss
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2023 |
Event name | tmnxEqFlashDataLoss |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.32 |
Default severity | major |
Source stream |
main |
Message format string | Class $tmnxHwClass$ : probable data loss |
Cause | tmnxEqFlashDataLoss is generated when an error occurs while data was being written to the compact flash. This notification indicates a probable data loss. |
Effect | N/A |
Recovery | N/A |
tmnxEqFlashDiskFull
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2024 |
Event name | tmnxEqFlashDiskFull |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.33 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : $tmnxChassisNotifyDiskFullReason$ |
Cause | tmnxEqFlashDiskFull is generated when there is no space left on the compact flash. No more data can be written to it. |
Effect | N/A |
Recovery | N/A |
tmnxEqFpgaSoftError
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2200 |
Event name | tmnxEqFpgaSoftError |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.211 |
Default severity |
minor |
Source stream | main |
Message format string | Slot $tmnxHwIndex$ detected an SEU event |
Cause | The tmnxEqFpgaSoftError notification is for experimental use only and should remain suppressed unless advised otherwise by Nokia customer support. |
Effect | Contact Nokia customer support. |
Recovery |
Contact Nokia customer support. |
tmnxEqHwEnhancedCapability
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2078 |
Event name | tmnxEqHwEnhancedCapability |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.66 |
Default severity |
major |
Source stream | main |
Message format string | CPM Upgrade In Progress. Card in slot $tmnxCardSlotNum$ has enhanced capabilities. |
Cause | The tmnxEqHwEnhancedCapability notification is generated when the hardware, specified by the supplied objects, consists of enhanced capabilities as compared to the active hardware. |
Effect | The system behaves normally under this situation, however, switching to the newer hardware will put the system in an incompatible state with the currently active hardware. That is, once this device takes activity, the lesser capable hardware will fail to communicate with it. In this mode, the system is deemed in a 'one-way upgrade' scenario. |
Recovery | Two modes of recovery exist for this notification: 1) Remove the enhanced hardware, and supply a more compatible device (status quo) with the active hardware. 2) Switch to the enhanced device, and replace the older hardware with a similarly enhanced device (upgrade). |
tmnxEqHwEventDetected
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2207 |
Event name | tmnxEqHwEventDetected |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.218 |
Default severity |
minor |
Source stream | main |
Message format string | $tmnxHwClass$ $tmnxChassisNotifyHwIndex$: $tmnxEqNotifyHwEventType$ event detected. (detail: $tmnxEqNotifyHwEventDetail$, action:$tmnxEqNotifyHwEventAction$) |
Cause |
Generated when events or errors being monitored are detected by hardware component. |
Effect | The system will perform the configured action on the hardware component. |
Recovery | Check hardware component. |
tmnxEqLowSwitchFabricCap
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2104 |
Event name | tmnxEqLowSwitchFabricCap |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.91 |
Default severity |
major |
Source stream | main |
Message format string | The switch fabric capacity is less than the forwarding capacity of $tmnxHwClass$ $tmnxHwIndex$ due to errors in fabric links. |
Cause |
The tmnxEqLowSwitchFabricCap alarm is generated when the total switch fabric capacity becomes less than the IOM capacity due to link failures. At least one of the taps on the IOM is below 100% capacity. |
Effect | There is diminished switch fabric capacity to forward service-impacting information. |
Recovery | If the system does not self-recover, the IOM must be rebooted. |
tmnxEqLowSwitchFabricCapClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2105 |
Event name | tmnxEqLowSwitchFabricCapClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.92 |
Default severity |
major |
Source stream | main |
Message format string | The switch fabric capacity alarm for $tmnxHwClass$ $tmnxHwIndex$ was cleared. |
Cause | The tmnxEqLowSwitchFabricCapClear notification is generated when the link failures that resulted in the tmnxEqLowSwitchFabricCap alarm to be raised have been resolved. |
Effect | There is sufficient switch fabric capacity to forward service-impacting information. |
Recovery | N/A |
tmnxEqMdaCfgNotCompatible
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2056 |
Event name | tmnxEqMdaCfgNotCompatible |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.44 |
Default severity | major |
Source stream |
main |
Message format string | Class $tmnxHwClass$ : configuration not compatible with equipped MDA |
Cause | Generated when a supported MDA is inserted into a slot of an IOM, the MDA is compatible with the currently provisioned MDA, but the current configuration on the MDA's ports is not compatible with the inserted MDA. |
Effect | Though services can still be created, if the tmnxMdaNotifyType is the same as the tmnxMDAEquippedType then the MDA will fail to operate as configured and will be in a failed state. |
Recovery | Change the configuration to reflect the capabilities of the MDA port, or switch out/re-provision the MDA for one that is compatible. |
tmnxEqMdaIngrXplError
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2129 |
Event name | tmnxEqMdaIngrXplError |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.116 |
Default severity |
minor |
Source stream | main |
Message format string | MDA $tmnxCardSlotNum$/$tmnxEqMdaSlotNum$ experienced an ingress XPL error occurrence. |
Cause | The tmnxEqMdaIngrXplError notification is generated when an MDA exhibits persistent ingress XPL errors. |
Effect | Contact Nokia customer support. |
Recovery |
Contact Nokia customer support. |
tmnxEqMdaSyncENotCompatible
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2061 |
Event name | tmnxEqMdaSyncENotCompatible |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.49 |
Default severity |
major |
Source stream | main |
Message format string | Provisioned synchronous ethernet not compatible with equipped MDA |
Cause | The tmnxEqMdaSyncENotCompatible notification is generated when an MDA card is inserted into a slot of an IOM. The MDA is compatible with the currently provisioned MDA, but the currently configured synchronous ethernet, tmnxMDASynchronousEthernet, is not compatible with the inserted MDA. |
Effect | Though services can still be created, if the tmnxMdaNotifyType is the same as the tmnxMDAEquippedType then the MDA will fail to operate as configured and will be in a failed state. |
Recovery | Change the configuration to reflect the capabilities of the MDA port, or switch out/re-provision the MDA for one that is compatible. |
tmnxEqMdaXplError
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2058 |
Event name | tmnxEqMdaXplError |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.46 |
Default severity |
minor |
Source stream | main |
Message format string | MDA $tmnxCardSlotNum$/$tmnxMDASlotNum$ experienced an egress XPL error occurrence. |
Cause | The tmnxEqMdaXplError notification is generated when an MDA exhibits persistent egress XPL Errors. |
Effect | N/A |
Recovery | N/A |
tmnxEqMgmtEthRedStandbyClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2137 |
Event name | tmnxEqMgmtEthRedStandbyClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.122 |
Default severity |
minor |
Source stream | main |
Message format string | The active CPM's management Ethernet port $tmnxChassisNotifyMgmtEthRedPort$ is serving as the system's management Ethernet port. |
Cause | The tmnxEqMgmtEthRedStandbyClear notification is generated when the active CPM's management Ethernet port goes operationally up and the management Ethernet port reverts from the standby CPM to the active CPM. |
Effect | The management of the node is operating from the active CPM's management Ethernet port and is redundant. |
Recovery | No recovery required. |
tmnxEqMgmtEthRedStandbyRaise
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2136 |
Event name | tmnxEqMgmtEthRedStandbyRaise |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.121 |
Default severity |
minor |
Source stream | main |
Message format string | The standby CPM's management Ethernet port $tmnxChassisNotifyMgmtEthRedPort$ is serving as the system's management Ethernet port. |
Cause | The tmnxEqMgmtEthRedStandbyRaise notification is generated when the active CPM's management Ethernet port goes operationally down and the standby CPM's management Ethernet port is operationally up and now serving as the system's management Ethernet port. |
Effect | The management Ethernet port is no longer redundant. The node can be managed via the standby CPM's management Ethernet port only. |
Recovery | Bring the active CPM's management Ethernet port operationally up. |
tmnxEqOperStateChange
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2055 |
Event name | tmnxEqOperStateChange |
SNMP notification prefix and OID |
TIMETRA-SYSTEM-MIB.tmnxSysNotifications.85 |
Default severity |
major |
Source stream | main |
Message format string | $tmnxNotifyObjectName$ changed operational state: $tmnxNotifyRowOperState$ |
Cause | The tmnxEqOperStateChange notification is generated when a change occurred in the operational state on the piece of hardware. |
Effect | If the state has changed to out of service, then all ports and services associated with the module change to out of service and traffic is impacted. |
Recovery | Investigation is required to determine the cause of the change. |
tmnxEqPhysChassisFanFailure
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2148 |
Event name | tmnxEqPhysChassisFanFailure |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.135 |
Default severity |
critical |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ fan $tmnxPhysChassisFanIndex$ failure |
Cause | The tmnxEqPhysChassisFanFailure notification is generated when one of the fans in a fan tray fails on a particular physical chassis. |
Effect | The fan is no longer operational. |
Recovery |
Insert a new fan. |
tmnxEqPhysChassisFanFailureClear
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2149 |
Event name | tmnxEqPhysChassisFanFailureClear |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.136 |
Default severity | cleared |
Source stream |
main |
Message format string | Chassis $tmnxPhysChassisNum$ fan $tmnxPhysChassisFanIndex$ failure cleared |
Cause | The tmnxEqPhysChassisFanFailureClear notification is generated when the fan failure is cleared on the particular physical chassis. |
Effect | The fan is operational again. |
Recovery |
There is no recovery for this notification. |
tmnxEqPhysChassPowerSupAcFail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2140 |
Event name | tmnxEqPhysChassPowerSupAcFail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.127 |
Default severity |
critical |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ AC failure |
Cause | The tmnxEqPhysChassPowerSupAcFail notification is generated when an AC failure occurs on the power supply. |
Effect | The power supply is no longer operational. |
Recovery | Insert a new power supply. |
tmnxEqPhysChassPowerSupAcFailClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2141 |
Event name | tmnxEqPhysChassPowerSupAcFailClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.128 |
Default severity |
cleared |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ AC failure cleared |
Cause | The tmnxEqPhysChassPowerSupAcFailClr notification is generated when the AC failure is cleared on the power supply. |
Effect | The power supply is operational again. |
Recovery | There is no recovery for this notification. |
tmnxEqPhysChassPowerSupDcFail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2142 |
Event name | tmnxEqPhysChassPowerSupDcFail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.129 |
Default severity |
critical |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ DC failure |
Cause | The tmnxEqPhysChassPowerSupDcFail notification is generated when a DC failure occurs on the power supply. |
Effect | The power supply is no longer operational. |
Recovery | Insert a new power supply. |
tmnxEqPhysChassPowerSupDcFailClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2143 |
Event name | tmnxEqPhysChassPowerSupDcFailClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.130 |
Default severity |
cleared |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ DC failure cleared |
Cause | The tmnxEqPhysChassPowerSupDcFailClr notification is generated when the DC failure is cleared on the power supply. |
Effect | The power supply is operational again. |
Recovery | There is no recovery for this notification. |
tmnxEqPhysChassPowerSupInFail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2144 |
Event name | tmnxEqPhysChassPowerSupInFail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.131 |
Default severity |
critical |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ input failure |
Cause | The tmnxEqPhysChassPowerSupInFail notification is generated when an input failure occurs on the power supply. |
Effect | The power supply is no longer operational. |
Recovery | Check input feed and/or insert a new power supply. |
tmnxEqPhysChassPowerSupInFailClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2145 |
Event name | tmnxEqPhysChassPowerSupInFailClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.132 |
Default severity |
cleared |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ input failure cleared |
Cause | The tmnxEqPhysChassPowerSupInFailClr notification is generated when the input failure is cleared on the power supply. |
Effect | The power supply is operational again. |
Recovery | There is no recovery for this notification. |
tmnxEqPhysChassPowerSupOutFail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2146 |
Event name | tmnxEqPhysChassPowerSupOutFail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.133 |
Default severity |
critical |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ output failure |
Cause | The tmnxEqPhysChassPowerSupOutFail notification is generated when an output failure occurs on the power supply. |
Effect | The power supply is no longer operational. |
Recovery | Insert a new power supply. |
tmnxEqPhysChassPowerSupOutFailCl
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2147 |
Event name | tmnxEqPhysChassPowerSupOutFailCl |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.134 |
Default severity |
cleared |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ output failure cleared |
Cause | The tmnxEqPhysChassPowerSupOutFailCl notification is generated when an output failure is cleared on the power supply. |
Effect | The power supply is operational again. |
Recovery | There is no recovery for this notification. |
tmnxEqPhysChassPowerSupOvrTmp
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2138 |
Event name | tmnxEqPhysChassPowerSupOvrTmp |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.125 |
Default severity |
critical |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ over temperature |
Cause | The tmnxEqPhysChassPowerSupOvrTmp notification is generated when a power supply's temperature surpasses the threshold of the particular physical chassis. |
Effect | The power supply is no longer operational. |
Recovery | Check input feed and/or insert a new power supply. |
tmnxEqPhysChassPowerSupOvrTmpClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2139 |
Event name | tmnxEqPhysChassPowerSupOvrTmpClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.126 |
Default severity |
cleared |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ over temperature cleared |
Cause | The tmnxEqPhysChassPowerSupOvrTmpClr notification is generated when a power supply's temperature is reduced below the threshold of the particular physical chassis. |
Effect | The power supply is operational again. |
Recovery | There is no recovery for this notification. |
tmnxEqPowerCapacityExceeded
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2092 |
Event name | tmnxEqPowerCapacityExceeded |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.80 |
Default severity |
minor |
Source stream | main |
Message format string | The system has reached maximum power capacity $tmnxChassisNotifyPowerCapacity$ watts |
Cause | The tmnxEqPowerCapacityExceeded alarm is generated when a device needs power to boot, but there is not enough power capacity to support the device. |
Effect | A non-powered device will not boot until the power capacity is increased to support the device. |
Recovery | Add a new power supply to the system or change the faulty power supply for a working one. |
tmnxEqPowerCapacityExceededClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2093 |
Event name | tmnxEqPowerCapacityExceededClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.81 |
Default severity |
minor |
Source stream | main |
Message format string | The system power capacity is sufficient to support installed devices |
Cause | The tmnxEqPowerCapacityExceededClear notification is generated when the available power capacity exceeds the required power to boot all inserted devices. |
Effect | Devices that failed to boot due to power constrains, power up. |
Recovery | N/A |
tmnxEqPowerLostCapacity
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2094 |
Event name | tmnxEqPowerLostCapacity |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.82 |
Default severity | major |
Source stream |
main |
Message format string | The system can no longer support configured devices. Power capacity dropped to $tmnxChassisNotifyPowerCapacity$ watts |
Cause | The tmnxEqPowerLostCapacity alarm is generated when a power supply fails or is removed which puts the system in an overloaded situation. |
Effect | Devices are powered off in order of lowest power priority (tmnxMDAHwPowerPriority) until the available power capacity can support the powered devices. |
Recovery | Add a new power supply to the system or change the faulty power supply for a working one. |
tmnxEqPowerLostCapacityClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2095 |
Event name | tmnxEqPowerLostCapacityClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.83 |
Default severity |
major |
Source stream | main |
Message format string | The system has reached a sustainable power capacity. |
Cause | The tmnxEqPowerLostCapacityClear notification is generated when the available power capacity exceeds the required power to boot all inserted devices. |
Effect | Devices that powered off due to power constrains, power up. |
Recovery | N/A |
tmnxEqPowerOverloadState
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2096 |
Event name | tmnxEqPowerOverloadState |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.84 |
Default severity | critical |
Source stream |
main |
Message format string | The system has reached critical power capacity. Increase available power now. |
Cause | The tmnxEqPowerOverloadState alarm is generated when the overloaded power capacity cannot support the power requirements and there are no further devices that can be powered off. |
Effect | The system runs a risk of experiencing brownouts while the available power capacity does not meet the required power consumption. |
Recovery | Add power capacity or manually shut down devices until the power capacity meets the power needs. |
tmnxEqPowerOverloadStateClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2097 |
Event name | tmnxEqPowerOverloadStateClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.85 |
Default severity |
critical |
Source stream | main |
Message format string | The system has reached a sustainable power capacity for critical equipment. |
Cause | The tmnxEqPowerOverloadStateClear notification is generated when the available power capacity meets or exceeds the power needs of the powered on devices. |
Effect | N/A |
Recovery | N/A |
tmnxEqPowerSafetyAlertClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2107 |
Event name | tmnxEqPowerSafetyAlertClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.94 |
Default severity |
minor |
Source stream | main |
Message format string | Possible messages:
|
Cause |
The tmnxEqPowerSafetyAlertClear notification is generated when the system power capacity raises above the configured safety alert threshold. |
Effect | This event is for notification only. |
Recovery |
N/A |
tmnxEqPowerSafetyAlertThreshold
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2106 |
Event name | tmnxEqPowerSafetyAlertThreshold |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.93 |
Default severity | minor |
Source stream |
main |
Message format string | The system power capacity for zone $tmnxChassisPwrMgmtZone$ dropped below the configured safety alert threshold of $tmnxChassisPwrMgmtSafetyAlert$ watts. |
Cause | The tmnxEqPowerSafetyAlertThreshold notification is generated when the system power capacity drops below the configured safety alert threshold. |
Effect | This event is for notification only. |
Recovery |
N/A |
tmnxEqPowerSafetyLevelClear
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2109 |
Event name | tmnxEqPowerSafetyLevelClear |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.96 |
Default severity | minor |
Source stream |
main |
Message format string | The peak nodal power for zone $tmnxChassisPwrMgmtZone$ consumption dropped below the configured safety level threshold of $tmnxChassisPwrMgmtSafetyLevel$ percent |
Cause | The tmnxEqPowerSafetyLevelClear notification is generated when the peak nodal power consumption drops below the configured safety level threshold. |
Effect | This event is for notification only. |
Recovery |
N/A |
tmnxEqPowerSafetyLevelThreshold
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2108 |
Event name | tmnxEqPowerSafetyLevelThreshold |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.95 |
Default severity | minor |
Source stream |
main |
Message format string | The peak nodal power for zone $tmnxChassisPwrMgmtZone$ consumption exceeded the configured safety level threshold of $tmnxChassisPwrMgmtSafetyLevel$ percent |
Cause | The tmnxEqPowerSafetyLevelThreshold notification is generated when the peak nodal power consumption exceeds the configured safety level threshold. |
Effect | This event is for notification only. |
Recovery |
N/A |
tmnxEqPowerSupplyInserted
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2010 |
Event name | tmnxEqPowerSupplyInserted |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.4 |
Default severity | major |
Source stream |
main |
Message format string | $tmnxChassisNotifyHwIndex$ inserted |
Cause | Generated when one of the chassis' power supplies is inserted. |
Effect | N/A |
Recovery | N/A |
tmnxEqPowerSupplyRemoved
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2011 |
Event name | tmnxEqPowerSupplyRemoved |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.5 |
Default severity |
major |
Source stream | main |
Message format string | $tmnxChassisNotifyHwIndex$, power lost |
Cause | The tmnxEqPowerSupplyRemoved notification is generated when one of the power supplies is removed from the chassis or low input voltage is detected. The operating voltage range for the 7750 SR-7 and 7750 SR-12 is -40 to -72 VDC. The notification is generated if the system detects that the voltage of the power supply has dropped to -42.5 VDC. |
Effect | Reduced power can cause intermittent errors and could also cause permanent damage to components. |
Recovery | Reinsert the power supply or raise the input voltage above -42.5 VDC. |
tmnxEqProvPowerCapacityAlm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2115 |
Event name | tmnxEqProvPowerCapacityAlm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.102 |
Default severity |
minor |
Source stream | main |
Message format string | The provisioned power capacity can no longer support configured devices. |
Cause | The tmnxEqProvPowerCapacityAlm notification is generated if a power zone's provisioned power capacity can no longer support configured devices. |
Effect | There is an increased risk of device power outages that may be service affecting. |
Recovery | Increase the provisioned power capacity. |
tmnxEqProvPowerCapacityAlmClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2116 |
Event name | tmnxEqProvPowerCapacityAlmClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.103 |
Default severity |
minor |
Source stream | main |
Message format string | The provisioned power capacity now supports configured devices. |
Cause | The tmnxEqProvPowerCapacityAlmClr notification is generated when the power zone's provisioned power capacity can support configured devices. |
Effect | All configured devices in the power zone have enough provisioned power capacity. |
Recovery | N/A |
tmnxEqSyncIfTimingBITS2Alarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2073 |
Event name | tmnxEqSyncIfTimingBITS2Alarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.61 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on BITS 2 reference |
Cause | Generated when an alarm condition on the BITS 2 timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingBITS2AlarmClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2074 |
Event name | tmnxEqSyncIfTimingBITS2AlarmClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.62 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on BITS 2 reference cleared |
Cause | Generated when an alarm condition on the BITS 2 timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingBITS2Quality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2071 |
Event name | tmnxEqSyncIfTimingBITS2Quality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.59 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference BITS2 received quality level $tmnxSyncIfTimingBITS2RxQltyLevel$ |
Cause | Generated when there is a change of the received quality level on the second bits interface. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingBITSAlarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2030 |
Event name | tmnxEqSyncIfTimingBITSAlarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.38 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on BITS $bits-two-supported$ reference |
Cause | Generated when an alarm condition on the BITS timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingBITSAlarmClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2031 |
Event name | tmnxEqSyncIfTimingBITSAlarmClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.39 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on BITS $bits-two-supported$ reference cleared |
Cause | Generated when an alarm condition on the BITS timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingBITSOutRefChg
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2075 |
Event name | tmnxEqSyncIfTimingBITSOutRefChg |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.63 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, BITS output timing reference changed to $tmnxSyncIfTimingBITSOutRefSel$ |
Cause | Generated when the BITS Out timing reference selection changes. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingBITSQuality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2070 |
Event name | tmnxEqSyncIfTimingBITSQuality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.58 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference BITS$bits-two-supported$ received quality level $tmnxSyncIfTimingBITSRxQltyLevel$ |
Cause | Generated when there is a change of the received quality level on the bits interface. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingGnss2Alarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2227 |
Event name | tmnxEqSyncIfTimingGnss2Alarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.238 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on GNSS2 reference |
Cause | Generated when an alarm condition on the gnss2 timing reference is detected. The type of alarm (los, oof, etc) is indicated in the details of the log event or alarm, and is also available in the tmnxSyncIfTimingNotifyAlarm attribute included in the SNMP notification. The SNMP notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | Timing reference gnss2 cannot be used as a source of timing into the central clock. |
Recovery | Address issues with the signal associated with timing reference gnss2. |
tmnxEqSyncIfTimingGnss2AlarmClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2229 |
Event name | tmnxEqSyncIfTimingGnss2AlarmClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.240 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on GNSS2 reference cleared |
Cause | Generated when an alarm condition on the gnss2 timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingGnss2Quality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2225 |
Event name | tmnxEqSyncIfTimingGnss2Quality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.236 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference GNSS2 received quality level $tmnxSyncIfTimingGnss2RxQltyLevel$ |
Cause | Generated when there is a change of the received quality level on timing reference gnss2. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingGnssAlarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2226 |
Event name | tmnxEqSyncIfTimingGnssAlarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.237 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on GNSS reference |
Cause | Generated when an alarm condition on the gnss timing reference is detected. The type of alarm (los, oof, etc) is indicated in the details of the log event or alarm, and is also available in the tmnxSyncIfTimingNotifyAlarm attribute included in the SNMP notification. The SNMP notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | Timing reference gnss cannot be used as a source of timing into the central clock. |
Recovery | Address issues with the signal associated with timing reference gnss. |
tmnxEqSyncIfTimingGnssAlarmClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2228 |
Event name | tmnxEqSyncIfTimingGnssAlarmClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.239 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on GNSS reference cleared |
Cause | Generated when an alarm condition on the gnss timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingGnssQuality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2224 |
Event name | tmnxEqSyncIfTimingGnssQuality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.235 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference GNSS received quality level $tmnxSyncIfTimingGnssRxQltyLevel$ |
Cause | Generated when there is a change of the received quality level on timing reference gnss. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingHoldover
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2017 |
Event name | tmnxEqSyncIfTimingHoldover |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.26 |
Default severity |
critical |
Source stream | main |
Message format string | Synchronous Timing interface in holdover state |
Cause | Generated when the synchronous equipment timing subsystem transitions into a holdover state. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | Any node-timed ports will have very slow frequency drift limited by the central clock oscillator stability. The oscillator meets the holdover requirements of a Stratum 3 and G.813 Option 1 clock. |
Recovery | Address issues with the central clock input references. |
tmnxEqSyncIfTimingHoldoverClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2018 |
Event name | tmnxEqSyncIfTimingHoldoverClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.27 |
Default severity |
critical |
Source stream | main |
Message format string | Synchronous Timing interface holdover state cleared |
Cause | Generated when the synchronous equipment timing subsystem transitions out of the holdover state. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingPTPAlarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2080 |
Event name | tmnxEqSyncIfTimingPTPAlarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.68 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on PTP reference |
Cause | Generated when an alarm condition on the Precision Timing Protocol (PTP) timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingPTPAlarmClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2081 |
Event name | tmnxEqSyncIfTimingPTPAlarmClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.69 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on PTP reference cleared |
Cause | Generated when an alarm condition on the Precision Timing Protocol (PTP) timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingPTPQuality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2079 |
Event name | tmnxEqSyncIfTimingPTPQuality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.67 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference PTP received quality level $tmnxSyncIfTimingPTPRxQltyLevel$ |
Cause | Generated when there is a change of the received quality level on the Precision Timing Protocol (PTP). |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingRef1Alarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2019 |
Event name | tmnxEqSyncIfTimingRef1Alarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.28 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on reference 1 |
Cause | Generated when an alarm condition on the first timing reference is detected. The type of alarm (los, oof, etc) is indicated in the details of the log event or alarm, and is also available in the tmnxSyncIfTimingNotifyAlarm attribute included in the SNMP notification. The SNMP notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | Indicated timing reference (1, 2, or BITS) cannot be used as a source of timing into the central clock. |
Recovery | Address issues with the signal associated with indicated timing reference (1, 2, or BITS). |
tmnxEqSyncIfTimingRef1AlarmClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2020 |
Event name | tmnxEqSyncIfTimingRef1AlarmClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.29 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on reference 1 cleared |
Cause | Generated when an alarm condition on the first timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingRef1Quality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2068 |
Event name | tmnxEqSyncIfTimingRef1Quality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.56 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference 1 received quality level $tmnxSyncIfTimingRef1RxQltyLevel$ |
Cause | Generated when there is a change of the received quality level on timing reference 1. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingRef2Alarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2021 |
Event name | tmnxEqSyncIfTimingRef2Alarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.30 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on reference 2 |
Cause | Generated when an alarm condition on the second timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingRef2AlarmClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2022 |
Event name | tmnxEqSyncIfTimingRef2AlarmClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.31 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on reference 2 cleared |
Cause | Generated when an alarm condition on the second timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingRef2Quality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2069 |
Event name | tmnxEqSyncIfTimingRef2Quality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.57 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference 2 received quality level $tmnxSyncIfTimingRef2RxQltyLevel$ |
Cause | Generated when there is a change of the received quality level on timing reference 2. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingRefSwitch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2072 |
Event name | tmnxEqSyncIfTimingRefSwitch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.60 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, timing reference changed to $tmnxSyncIfTimingRef1InUse$ |
Cause | Generated when there is a change of which timing reference is providing timing for the system. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingSyncE2Alarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2205 |
Event name | tmnxEqSyncIfTimingSyncE2Alarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.216 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on SYNCE2 reference |
Cause | Generated when an alarm condition on the SYNCE 2 timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingSyncE2AlarmClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2206 |
Event name | tmnxEqSyncIfTimingSyncE2AlarmClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.217 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on SYNCE2 reference cleared |
Cause | Generated when an alarm condition on the SYNCE 2 timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingSyncE2Quality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2202 |
Event name | tmnxEqSyncIfTimingSyncE2Quality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.213 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference SYNCE2 received quality level $tmnxSyncIfTimingSyncE2RxQltyLevl$ |
Cause | Generated when there is a change of the received quality level on timing reference synce2. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingSyncEAlarm
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2203 |
Event name | tmnxEqSyncIfTimingSyncEAlarm |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.214 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on SYNCE reference |
Cause | Generated when an alarm condition on the SYNCE timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingSyncEAlarmClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2204 |
Event name | tmnxEqSyncIfTimingSyncEAlarmClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.215 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on SYNCE reference cleared |
Cause | Generated when an alarm condition on the SYNCE timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingSyncEQuality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2201 |
Event name | tmnxEqSyncIfTimingSyncEQuality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.212 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, reference SYNCE received quality level $tmnxSyncIfTimingSyncERxQltyLevel$ |
Cause | Generated when there is a change of the received quality level on timing reference synce. |
Effect | N/A |
Recovery | N/A |
tmnxEqSyncIfTimingSystemQuality
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2077 |
Event name | tmnxEqSyncIfTimingSystemQuality |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.65 |
Default severity |
minor |
Source stream | main |
Message format string | Synchronous Timing interface, System Quality Level changed to $tmnxSyncIfTimingSystemQltyLevel$ |
Cause | This notification may be triggered for the following reasons: 1) There has been a switch in the timing reference in use by the network element, either because the previously active timing reference was disqualified, or to ensure that the network element is using the timing reference with the best timing quality. 2) There has been a change in the active timing reference's quality and the change does not result in a timing reference switch. 3) The network element has transitioned into or out of the holdover state. |
Effect | The system quality level is used to determine the SSM code transmitted on synchronous interfaces. This may affect the SSM code transmitted on some or all interfaces, which may affect the distribution of timing throughout the network. |
Recovery | If the customer is expecting the system to be locked to a reference of a particular quality and the system quality has decreased, the customer will need to determine the root cause (for example, loss of communication with a satellite) and resolve the issue. |
tmnxEqWrongCard
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2004 |
Event name | tmnxEqWrongCard |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.10 |
Default severity | minor |
Source stream |
main |
Message format string | Class $tmnxHwClass$ : wrong type inserted |
Cause | Generated when the wrong type of card is inserted into a slot of the chassis. Even though a card may be physically supported by the slot, it may have been administratively configured to allow only certain card types in a particular slot location. The card type may be IOM (or XCM), Fabric, MDA (or XMA), MCM, CPM module, etc. |
Effect | The effect is dependent on the card that has been incorrectly inserted. Incorrect IOM (or XCM) or MDA (or XMA) insertion will cause a loss of service for all services running on that card. |
Recovery | Insert the correct card into the correct slot, and ensure the slot is configured for the correct type of card. |
tmnxEsaCleared
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2213 |
Event name | tmnxEsaCleared |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.224 |
Default severity | major |
Source stream |
main |
Message format string | ESA $tmnxEsaNotifyId$ cleared |
Cause | The tmnxEsaCleared notification is generated when an ESA is cleared or rebooted. |
Effect | N/A |
Recovery | N/A |
tmnxEsaConnected
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2210 |
Event name | tmnxEsaConnected |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.221 |
Default severity |
minor |
Source stream | main |
Message format string | ESA $tmnxEsaNotifyId$ connected |
Cause | The tmnxEsaConnected notification is generated when a new ESA is connected. |
Effect | N/A |
Recovery | N/A |
tmnxEsaDisconnected
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2211 |
Event name | tmnxEsaDisconnected |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.222 |
Default severity |
major |
Source stream | main |
Message format string | ESA $tmnxEsaNotifyId$ disconnected |
Cause | The tmnxEsaDisconnected notification is generated when an ESA is disconnected. |
Effect | N/A |
Recovery | N/A |
tmnxEsaDiscovered
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2209 |
Event name | tmnxEsaDiscovered |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.220 |
Default severity |
minor |
Source stream | main |
Message format string | ESA $tmnxEsaNotifyId$ discovered |
Cause | The tmnxEsaDiscovered notification is generated when a new ESA is discovered by the system. |
Effect | N/A |
Recovery | N/A |
tmnxEsaFailure
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2212 |
Event name | tmnxEsaFailure |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.223 |
Default severity | major |
Source stream |
main |
Message format string | ESA $tmnxEsaNotifyId$ failed with reason $tmnxEsaStatsOperFlags$ |
Cause | The tmnxEsaFailure notification is generated when a failure occurs on an ESA. |
Effect | N/A |
Recovery | N/A |
tmnxEsaFirmwareUpgradeStarted
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2230 |
Event name | tmnxEsaFirmwareUpgradeStarted |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.241 |
Default severity |
minor |
Source stream | main |
Message format string | ESA $tmnxEsaNotifyId$ Firmware upgrade started |
Cause | The tmnxEsaFirmwareUpgradeStarted notification is generated when an ESA requests a firmware upgrade and is in progress. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwFanBankFailRedun
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2414 |
Event name | tmnxEsaHwFanBankFailRedun |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.279 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ fan bank status failed-redundant |
Cause | The tmnxEsaHwFanBankFailRedun notification is generated when one or more ESA fans fail, compromising the fan bank redundancy. |
Effect | ESA cooling may be inadequate if fan failure occurs. |
Recovery | Contact Nokia customer support. |
tmnxEsaHwFanBankFailRedunClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2415 |
Event name | tmnxEsaHwFanBankFailRedunClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.280 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ fan bank failed-redundant status cleared, now $tmnxEsaStatsFanRedundancy$ |
Cause | The tmnxEsaHwFanBankFailRedunClr notification is generated when all ESA fans recover, restoring the fan bank redundancy. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwFanBankNonRedun
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2412 |
Event name | tmnxEsaHwFanBankNonRedun |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.277 |
Default severity |
major |
Source stream | main |
Message format string | ESA $tmnxHwClass$ fan bank status non-redundant |
Cause | The tmnxEsaHwFanBankNonRedun notification is generated when a condition compromises the ESA fan bank redundancy. |
Effect | ESA cooling may be inadequate if fan failure occurs. |
Recovery | Contact Nokia customer support. |
tmnxEsaHwFanBankNonRedunClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2413 |
Event name | tmnxEsaHwFanBankNonRedunClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.278 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ fan bank non-redundant status cleared, now $tmnxEsaStatsFanRedundancy$ |
Cause | The tmnxEsaHwFanBankNonRedunClr notification is generated when the ESA fan bank redundancy is restored. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwFanStatusDegraded
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2416 |
Event name | tmnxEsaHwFanStatusDegraded |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.281 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ fan status degraded |
Cause | The tmnxEsaHwFanStatusDegraded notification is generated when one or more ESA fans are degraded. |
Effect | ESA cooling may be inadequate. |
Recovery |
Contact Nokia customer support. |
tmnxEsaHwFanStatusDegradedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2417 |
Event name | tmnxEsaHwFanStatusDegradedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.282 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ fan degraded status cleared, now $tmnxEsaStatsFanStatus$ |
Cause | The tmnxEsaHwFanStatusDegradedClr notification is generated when ESA fans are no longer degraded. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwFanStatusFailed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2418 |
Event name | tmnxEsaHwFanStatusFailed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.283 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ fan status failed |
Cause | The tmnxEsaHwFanStatusFailed notification is generated when one or more ESA fans fail. |
Effect | ESA cooling may be inadequate. |
Recovery |
Contact Nokia customer support. |
tmnxEsaHwFanStatusFailedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2419 |
Event name | tmnxEsaHwFanStatusFailedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.284 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ fan failed status cleared, now $tmnxEsaStatsFanStatus$ |
Cause | The tmnxEsaHwFanStatusFailedClr notification is generated when the ESA fans are restored. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwPwrSup1Degraded
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2404 |
Event name | tmnxEsaHwPwrSup1Degraded |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.269 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply 1 status degraded |
Cause | The tmnxEsaHwPwrSup1Degraded notification is generated when the ESA power supply 1 is degraded. |
Effect | Power supply operation and reliability may be affected. |
Recovery | Contact Nokia customer support. |
tmnxEsaHwPwrSup1DegradedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2405 |
Event name | tmnxEsaHwPwrSup1DegradedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.270 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply 1 degraded status cleared, now $tmnxEsaStatsPowerSupply1Status$ |
Cause | The tmnxEsaHwPwrSup1DegradedClr notification is generated when the ESA power supply 1 is no longer degraded. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwPwrSup1Failed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2406 |
Event name | tmnxEsaHwPwrSup1Failed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.271 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply 1 status failed |
Cause | The tmnxEsaHwPwrSup1Failed notification is generated when the ESA power supply 1 fails. |
Effect | Power supply and redundancy are affected. ESA operation may be affected. |
Recovery | Contact Nokia customer support. |
tmnxEsaHwPwrSup1FailedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2407 |
Event name | tmnxEsaHwPwrSup1FailedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.272 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply 1 failed status cleared, now $tmnxEsaStatsPowerSupply1Status$ |
Cause | The tmnxEsaHwPwrSup1FailedClr notification is generated when the ESA power supply 1 is restored. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwPwrSup2Degraded
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2408 |
Event name | tmnxEsaHwPwrSup2Degraded |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.273 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply 2 status degraded |
Cause | The tmnxEsaHwPwrSup2Degraded notification is generated when the ESA power supply 2 is degraded. |
Effect | Power supply operation and reliability may be affected. |
Recovery | Contact Nokia customer support. |
tmnxEsaHwPwrSup2DegradedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2409 |
Event name | tmnxEsaHwPwrSup2DegradedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.274 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply 2 degraded status cleared, now $tmnxEsaStatsPowerSupply2Status$ |
Cause | The tmnxEsaHwPwrSup2DegradedClr notification is generated when the ESA power supply 2 is no longer degraded. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwPwrSup2Failed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2410 |
Event name | tmnxEsaHwPwrSup2Failed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.275 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply 2 status failed |
Cause | The tmnxEsaHwPwrSup2Failed notification is generated when the ESA power supply 2 fails. |
Effect | Power supply and redundancy are affected. ESA operation may be affected. |
Recovery | Contact Nokia customer support. |
tmnxEsaHwPwrSup2FailedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2411 |
Event name | tmnxEsaHwPwrSup2FailedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.276 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply 2 failed status cleared, now $tmnxEsaStatsPowerSupply2Status$ |
Cause | The tmnxEsaHwPwrSup2FailedClr notification is generated when the ESA power supply 2 is restored. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwPwrSupBankFailRedun
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2424 |
Event name | tmnxEsaHwPwrSupBankFailRedun |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.289 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply bank status failed-redundant |
Cause | The tmnxEsaHwPwrSupBankFailRedun notification is generated when the ESA power supply redundancy fails. |
Effect | ESA operation may be affected if additional power supply failures occur. |
Recovery | Contact Nokia customer support. |
tmnxEsaHwPwrSupBankFailRedunClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2425 |
Event name | tmnxEsaHwPwrSupBankFailRedunClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.290 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply bank failed-redundant status cleared, now $tmnxEsaStatsPwrSupRedundancy$ |
Cause | The tmnxEsaHwPwrSupBankFailRedunClr notification is generated when the ESA power supplies regain redundancy. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwPwrSupBankNonRedun
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2422 |
Event name | tmnxEsaHwPwrSupBankNonRedun |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.287 |
Default severity |
major |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply bank status non-redundant |
Cause | The tmnxEsaHwPwrSupBankNonRedun notification is generated when the ESA power supply redundancy is degraded. |
Effect | ESA may lose power supply redundancy if power supply failures occur. |
Recovery | Contact Nokia customer support. |
tmnxEsaHwPwrSupBankNonRedunClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2423 |
Event name | tmnxEsaHwPwrSupBankNonRedunClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.288 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply bank non-redundant status cleared, now $tmnxEsaStatsPwrSupRedundancy$ |
Cause | The tmnxEsaHwPwrSupBankNonRedunClr notification is generated when the ESA power supplies return to a fully redundant state. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwPwrSupMismatch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2420 |
Event name | tmnxEsaHwPwrSupMismatch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.285 |
Default severity |
major |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply mismatch |
Cause | The tmnxEsaHwPwrSupMismatch notification is generated when the ESA power supplies do not match. |
Effect | ESA power supplies must be matched. |
Recovery |
Equip the ESA with matching power supplies. |
tmnxEsaHwPwrSupMismatchClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2421 |
Event name | tmnxEsaHwPwrSupMismatchClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.286 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ power supply mismatch - cleared, now $tmnxEsaStatsPwrSupMismatchStatus$ |
Cause | The tmnxEsaHwPwrSupMismatchClr notification is generated when the ESA power supplies are no longer mismatched. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwStatusCritical
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2402 |
Event name | tmnxEsaHwStatusCritical |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.267 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ aggregate hardware status critical |
Cause | The tmnxEsaHwStatusCritical notification is generated when the ESA hardware status is critical. |
Effect | Service may be affected. |
Recovery |
Contact Nokia customer support. |
tmnxEsaHwStatusCriticalClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2403 |
Event name | tmnxEsaHwStatusCriticalClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.268 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ aggregate hardware status critical - cleared, now $tmnxEsaStatsHardwareStatus$ |
Cause | The tmnxEsaHwStatusCriticalClr notification is generated when the ESA hardware status is no longer critical. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwStatusDegraded
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2400 |
Event name | tmnxEsaHwStatusDegraded |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.265 |
Default severity |
major |
Source stream | main |
Message format string | ESA $tmnxHwClass$ aggregate hardware status degraded |
Cause | The tmnxEsaHwStatusDegraded notification is generated when one or more ESA hardware components are degraded. |
Effect | Service may be affected. |
Recovery |
Contact Nokia customer support. |
tmnxEsaHwStatusDegradedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2401 |
Event name | tmnxEsaHwStatusDegradedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.266 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ aggregate hardware degraded status cleared, now $tmnxEsaStatsHardwareStatus$ |
Cause | The tmnxEsaHwStatusDegradedClr notification is generated when ESA hardware components are no longer degraded. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwTemperatureDegraded
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2426 |
Event name | tmnxEsaHwTemperatureDegraded |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.291 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ temperature status degraded |
Cause | The tmnxEsaHwTemperatureDegraded notification is generated when the ESA temperature is outside the expected operating range. |
Effect | If the ESA temperature remains outside the expected operating range, the ESA may shut down. |
Recovery | The ESA may need manual maintenance to rectify the issue. Contact Nokia customer support. |
tmnxEsaHwTemperatureDegradedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2427 |
Event name | tmnxEsaHwTemperatureDegradedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.292 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ temperature degraded status cleared, now $tmnxEsaStatsTemperatureStatus$ |
Cause | The tmnxEsaHwTemperatureDegradedClr notification is generated when the ESA returns to a temperature within the expected operating range. |
Effect | N/A |
Recovery | N/A |
tmnxEsaHwTemperatureFailed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2428 |
Event name | tmnxEsaHwTemperatureFailed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.293 |
Default severity |
critical |
Source stream | main |
Message format string | ESA $tmnxHwClass$ temperature status failed |
Cause | The tmnxEsaHwTemperatureFailed notification is generated when the ESA temperature is critical. |
Effect | If the ESA temperature remains outside the expected operating range, the ESA may shut down. |
Recovery | The ESA may need manual maintenance to rectify the issue. Contact Nokia customer support. |
tmnxEsaHwTemperatureFailedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2429 |
Event name | tmnxEsaHwTemperatureFailedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.294 |
Default severity |
cleared |
Source stream | main |
Message format string | ESA $tmnxHwClass$ temperature failed status cleared, now $tmnxEsaStatsTemperatureStatus$ |
Cause | The tmnxEsaHwTemperatureFailedClr notification is generated when the ESA returns to a temperature within the expected operating range. |
Effect | N/A |
Recovery | N/A |
tmnxEsaStolenTimeDetected
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2399 |
Event name | tmnxEsaStolenTimeDetected |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.305 |
Default severity |
major |
Source stream | main |
Message format string | ESA $tmnxEsaNotifyId$ detected $stolenTimeEvent$ |
Cause | The tmnxEsaStolenTimeDetected notification is generated when stolen time monitoring on the ESA detects periods of time that ESA-VMs are ready to run, but are unable to do so. The stolen time is reported in ms. |
Effect | If the periods of stolen time exceeds a certain value, they may result in ESA-VM reset or temporary loss of connection of the ESA with the host node. |
Recovery | Before taking any recovery steps, collect a tech-support and consult with support for best recovery method. |
tmnxEsaVmBooted
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2215 |
Event name | tmnxEsaVmBooted |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.226 |
Default severity | major |
Source stream |
main |
Message format string | ESA-VM $tmnxEsaNotifyId$/ $tmnxEsaVmNotifyId$ booted |
Cause | The tmnxEsaVmBooted notification is generated when an ESA VM is booted. |
Effect | N/A |
Recovery | N/A |
tmnxEsaVmCleared
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2217 |
Event name | tmnxEsaVmCleared |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.228 |
Default severity |
minor |
Source stream | main |
Message format string | ESA-VM $tmnxEsaNotifyId$/$tmnxEsaVmNotifyId$ reset |
Cause | The tmnxEsaVmCleared notification is generated when an ESA VM is cleared or restarted. |
Effect | N/A |
Recovery | N/A |
tmnxEsaVmCreated
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2214 |
Event name | tmnxEsaVmCreated |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.225 |
Default severity |
major |
Source stream | main |
Message format string | ESA-VM $tmnxEsaNotifyId$/$tmnxEsaVmNotifyId$ created |
Cause | The tmnxEsaVmCreated notification is generated when an ESA VM is created. |
Effect | N/A |
Recovery | N/A |
tmnxEsaVmFailure
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2218 |
Event name | tmnxEsaVmFailure |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.229 |
Default severity |
major |
Source stream | main |
Message format string | ESA-VM $tmnxEsaNotifyId$/$tmnxEsaVmNotifyId$ failed with reason $tmnxEsaVmStatsOperFlags$ |
Cause | The tmnxEsaVmFailure notification is generated when an ESA VM crashes. |
Effect | N/A |
Recovery | N/A |
tmnxEsaVmRemoved
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2216 |
Event name | tmnxEsaVmRemoved |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.227 |
Default severity |
major |
Source stream | main |
Message format string | ESA-VM $tmnxEsaNotifyId$/$tmnxEsaVmNotifyId$ destroyed |
Cause | The tmnxEsaVmRemoved notification is generated when an ESA VM is removed. |
Effect | N/A |
Recovery | N/A |
tmnxExtStandbyCpmReboot
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2127 |
Event name | tmnxExtStandbyCpmReboot |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.114 |
Default severity |
warning |
Source stream | main |
Message format string | Rebooting extension standby CPM due to master standby CPM reboot and transition into or out of an ISSU state. |
Cause | The tmnxExtStandbyCpmReboot notification is generated after a master standby CPM reboots and it is determined that the master standby CPM has transitioned into or out of an ISSU state. This detected transition will cause a reboot of the extension standby CPM (this reboot is necessary and expected for ISSU operation). This notification helps an operator understand why an extension standby CPM may have rebooted. |
Effect | The extension standby CPM will reboot. |
Recovery | There is no recovery for this notification. |
tmnxExtStandbyCpmRebootFail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2128 |
Event name | tmnxExtStandbyCpmRebootFail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.115 |
Default severity |
minor |
Source stream | main |
Message format string | Unable to automatically reboot extension standby CPM during ISSU. |
Cause | The tmnxExtStandbyCpmRebootFail notification is generated after a master standby CPM reboots and it is determined that the master standby CPM has transitioned into or out of an ISSU state. The system will attempt to reboot the extension standby CPM as part of the normal ISSU process. If the system determines that it cannot reboot the extension standby CPM (i.e. it is not reachable) then this log event is raised. |
Effect | The extension standby CPM may not transition to the ISSU state in which case the ISSU cannot proceed normally. |
Recovery | Resetting the extension standby CPM can be attempted to try and get the CPM into an ISSU state. If that is not successful, then the ISSU should be aborted. |
tmnxFPResourcePolicyModified
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2222 |
Event name | tmnxFPResourcePolicyModified |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.233 |
Default severity |
minor |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Card : FP resource policy changed, the configuration must be saved and the system rebooted immediately |
Cause | The FP resource policy applied to the FP has been modified, or a different FP resource policy is applied to the FP. |
Effect | Modifying the configuration could result in a failure to instantiate queues. |
Recovery | The configuration must be saved and the system rebooted immediately. |
tmnxFPResourcePolicyModifiedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2223 |
Event name | tmnxFPResourcePolicyModifiedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.234 |
Default severity |
minor |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Card : alarm $tmnxFPResourcePolicyModified$ cleared |
Cause | Generates a notification when tmnxFPResourcePolicyModified is cleared. |
Effect | None. |
Recovery | None. |
tmnxFPResOversubscribed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2246 |
Event name | tmnxFPResOversubscribed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.263 |
Default severity |
major |
Source stream | main |
Message format string | Card $tmnxCardSlotNum$ FP $tmnxFPNum$ resources oversubscribed: $tFPResOversub$ |
Cause | The tmnxFPResOversubscribed notification is generated when one or more of the FP resources have been oversubscribed. |
Effect | Usage beyond limits can result in the system dropping packets which may cause degradation in service quality. |
Recovery | Reduce traffic load and/or conjestion on the system. More specific action might be required depending on the specific oversubscription. |
tmnxFPResOversubscribedCleared
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2247 |
Event name | tmnxFPResOversubscribedCleared |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.264 |
Default severity |
cleared |
Source stream | main |
Message format string | Card $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFabricSlotNum$ resources no longer oversubscribed |
Cause | The tmnxFPResOversubscribedCleared notification is generated when none of the FP resources are oversubscribed. |
Effect | The system returns to normal mode of operation and can service all the received traffic in the configured manner. |
Recovery | There is no recovery for this notification. |
tmnxGnssAcquiredFix
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2189 |
Event name | tmnxGnssAcquiredFix |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.180 |
Default severity |
minor |
Source stream | main |
Message format string | GNSS Receiver - position fix obtained |
Cause | The tmnxGnssAcquiredFix notification is generated when the GNSS receiver has acquired a valid fix on its position. |
Effect | The position of the system is known. |
Recovery |
None needed |
tmnxGnssAcquiringFix
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2188 |
Event name | tmnxGnssAcquiringFix |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.179 |
Default severity | minor |
Source stream |
main |
Message format string | GNSS Receiver - attempting to acquire a position fix |
Cause | The tmnxGnssAcquiringFix notification is generated when the GNSS receiver starts to acquire a fix. This occurs when the GNSS receiver is enabled, and also when the GNSS receiver loses its fix. |
Effect | The position of the system is unknown until the receiver acquires a fix. |
Recovery | Ensure that the GNSS antenna is properly connected to the system. |
tmnxHwAggShpSchedEventOvrflw
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2243 |
Event name | tmnxHwAggShpSchedEventOvrflw |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.260 |
Default severity |
minor |
Source stream | main |
Message format string | Hw Agg Shaped Sched log event overflow occurred on card $tmnxChassisNotifyCardSlotNum$ at $tmnxHwAggShpTimeEventOccured$ |
Cause | The tmnxHwAggShpSchedEventOvrflwClr notification is generated when HW Agg Shaper Scheduler oper color occurs more than 200 times because of Number of agg-shapers parented to a scheduler. The IOM raises the final trap to indicate overflow and stops logging traps. |
Effect | Hw Agg shaper scheduler color notifications on the card may not be received. |
Recovery | Notifications will resume once the Overflow clear is set. |
tmnxHwAggShpSchedEventOvrflwClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2242 |
Event name | tmnxHwAggShpSchedEventOvrflwClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.259 |
Default severity |
minor |
Source stream | main |
Message format string | $tmnxHwAggShpMissingNotifCount$ HW Agg Shaper Sched events were dropped in the last event throttling interval on card $tmnxChassisNotifyCardSlotNum$ at $tmnxHwAggShpTimeEventOccured$ |
Cause |
The tmnxHwAggShpSchedEventOvrflwClr notification is generated when the CPM polls the IOM for Hw Agg Shaper Sched traps and the overflow is cleared by logging an overflow-clear on a particular card. |
Effect | Notifications are received again since the event throttling has ended. |
Recovery | There is no recovery for this notification. |
tmnxInterChassisCommsDown
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4001 |
Event name | tmnxInterChassisCommsDown |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxInterChassisNotifications.1 |
Default severity |
critical |
Source stream | main |
Message format string | Control communications disrupted between the active CPM and the chassis |
Cause | The tmnxInterChassisCommsDown alarm is generated when the active CPM cannot reach the far-end chassis. |
Effect | The resources on the far-end chassis are not available. This event for the far-end chassis means that the CPM, SFM, and XCM cards in the far-end chassis will reboot and remain operationally down until communications are re-established. |
Recovery | Ensure that all CPM interconnect ports in the system are properly cabled together with working cables. |
tmnxInterChassisCommsUp
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4002 |
Event name | tmnxInterChassisCommsUp |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxInterChassisNotifications.2 |
Default severity |
critical |
Source stream | main |
Message format string | Control communications established between the active CPM and the chassis |
Cause | The tmnxInterChassisCommsUp notification is generated when the control communications are re-established between the active CPM and the far-end chassis. |
Effect | The resources on the far-end chassis are now available. This event for the far-end chassis means that the CPM, SFM and XCM cards in the far-end chassis will start the process of coming back into service. |
Recovery | N/A |
tmnxIomEventOverflow
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
2124 |
Event name | tmnxIomEventOverflow |
SNMP notification prefix and OID | TIMETRA-CHASSIS-MIB.tmnxChassisNotification.111 |
Default severity | minor |
Source stream |
main |
Message format string | Iom $tmnxIomResourceType$ Resource event overflow occurred on card $tmnxChassisNotifyCardSlotNum$ at $tmnxIomResLimitTimeEventOccured$. |
Cause | The tmnxIomEventOverflow notification is generated when tmnxIomResStateClr, tmnxIomResExhausted and tmnxIomResHighLimitReached occur more than 200 times because of resource usage fluctuation. The IOM raises the final trap to indicate overflow and stops logging traps. |
Effect | Some FP notifications configured on the card may not be received. |
Recovery | Notifications will resume once the Overflow clear is set. |
tmnxIomEventOverflowClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2125 |
Event name | tmnxIomEventOverflowClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.112 |
Default severity |
minor |
Source stream | main |
Message format string | $tmnxIomResLimMissingNotifCount$ Iom $tmnxIomResourceType$ Resources events were dropped in the last event throttling interval on card $tmnxChassisNotifyCardSlotNum$ at $tmnxIomResLimitTimeEventOccured$. |
Cause | The tmnxIomEventOverflowClr notification is generated when the CPM polls the IOM for traps and the overflow is cleared by logging an overflow-clear on a particular card. |
Effect | Notifications are received again since the event throttling has ended. |
Recovery | There is no recovery for this notification. |
tmnxIomResExhausted
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2122 |
Event name | tmnxIomResExhausted |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.109 |
Default severity |
critical |
Source stream | main |
Message format string | The $tmnxIomResourceType$ resources on IOM $tmnxChassisNotifyCardSlotNum$ and Forwarding Plane $tmnxChassisNotifyFpNum$ has been exhausted at $tmnxIomResLimitTimeEventOccured$. |
Cause | The tmnxIomResExhausted notification is generated when the type of resources on IOM as specified by tmnxIomResourceType has reached the 100% of its utilization threshold. |
Effect | The specified resource has reached the stats pool limit. |
Recovery | Intervention may be required to recover resources. |
tmnxIomResHighLimitReached
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2121 |
Event name | tmnxIomResHighLimitReached |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.108 |
Default severity |
major |
Source stream | main |
Message format string | The $tmnxIomResourceType$ resources on IOM $tmnxChassisNotifyCardSlotNum$ and Forwarding Plane $tmnxChassisNotifyFpNum$ has reached the $tmnxIomResourceLimitPct$% utilization threshold at $tmnxIomResLimitTimeEventOccured$. |
Cause | The tmnxIomResHighLimitReached notification is generated when the resource (of type tmnxIomResourceType) utilization on IOM has reached the value of tmnxIomResourceLimitPct. |
Effect | The specified resource limit is cleared when the number of in-use stats resources falls below the clear threshold of the stats pool limit. |
Recovery | There is no recovery required for this notification. |
tmnxIomResStateClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2123 |
Event name | tmnxIomResStateClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.110 |
Default severity |
minor |
Source stream | main |
Message format string | The $tmnxIomResourceType$ resources on IOM $tmnxChassisNotifyCardSlotNum$ and Forwarding Plane $tmnxChassisNotifyFpNum$ has dropped below the $tmnxIomResourceLimitPct$% utilization threshold at $tmnxIomResLimitTimeEventOccured$. |
Cause | The tmnxIomResStateClr notification is generated when the type of resources on IOM as specified by tmnxIomResourceType has dropped back down below the value of tmnxIomResourceLimitPct. |
Effect | The specified resource limit is cleared when the number of in-use stats resources falls below tmnxIomResourceLimitPct of the stats pool limit. |
Recovery | There is no recovery required for this notification. |
tmnxIomRsrcEventOverflow
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3257 |
Event name | tmnxIomRsrcEventOverflow |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.257 |
Default severity |
warning |
Source stream | main |
Message format string | A resource event overflow occurred on card $tmnxChassisNotifyCardSlotNum$ at $tmnxIomRsrcTimeEventOccured$. |
Cause | The tmnxIomRsrcEventOverflow notification is generated when tmnxIomRsrcUsageHighLimitReached, tmnxIomRsrcUsageExhausted, tmnxIomRsrcUsageRecovered, tmnxIomRsrcOwnerOversubscribed, or tmnxIomRsrcOwnerOversubscrbdClr occur more than 200 times because of resource usage fluctuation. The IOM raises the final trap to indicate overflow and stops logging traps. |
Effect | Some IOM notifications may not be received. |
Recovery | Notifications will resume once the Overflow clear is set. |
tmnxIomRsrcEventOverflowClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3258 |
Event name | tmnxIomRsrcEventOverflowClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.258 |
Default severity |
minor |
Source stream | main |
Message format string | $tmnxIomRsrcMissingNotifCount$ resource events were dropped in the last event throttling interval on card $tmnxChassisNotifyCardSlotNum$ at $tmnxIomRsrcTimeEventOccured$. |
Cause |
The tmnxIomRsrcEventOverflowClr notification is generated when the CPM polls the IOM for traps and the overflow is cleared by logging an overflow-clear on a particular card. |
Effect | Notifications are received again since the event throttling has ended. |
Recovery | There is no recovery for this notification. |
tmnxIomRsrcOwnerOversubscrbdClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3260 |
Event name | tmnxIomRsrcOwnerOversubscrbdClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.262 |
Default severity |
minor |
Source stream | main |
Message format string | The $tmnxIomRsrcResourceType$ resources needed by $tmnxIomRsrcOwnerType$ on card $tmnxChassisNotifyCardSlotNum$ have been satisfied at $tmnxIomRsrcTimeEventOccured$. All $tmnxIomRsrcOwnerType$ traffic can flow. |
Cause | The tmnxIomRsrcOwnerOversubscrbdClr notification is generated when all the required IOM resources of type tmnxIomRsrcResourceType for owner tmnxIomRsrcOwnerType have been allocated. |
Effect | Traffic for owner tmnxIomRsrcOwnerType is no longer affected. |
Recovery | There is no recovery for this notification. |
tmnxIomRsrcOwnerOversubscribed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3259 |
Event name | tmnxIomRsrcOwnerOversubscribed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.261 |
Default severity |
major |
Source stream | main |
Message format string | The $tmnxIomRsrcResourceType$ resources needed by $tmnxIomRsrcOwnerType$ on card $tmnxChassisNotifyCardSlotNum$ are oversubscribed at $tmnxIomRsrcTimeEventOccured$. Some $tmnxIomRsrcOwnerType$ traffic may not flow. |
Cause | The tmnxIomRsrcOwnerOversubscribed notification is generated when the IOM resource of type tmnxIomRsrcResourceType has been exhausted for owner tmnxIomRsrcOwnerType. |
Effect | Traffic for owner tmnxIomRsrcOwnerType may be affected. |
Recovery | Intervention may be required to recover resources. |
tmnxIomRsrcUsageExhausted
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3253 |
Event name | tmnxIomRsrcUsageExhausted |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.253 |
Default severity |
critical |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxIomRsrcUsageExhausted notification is generated when all the IOM resources of type tmnxIomRsrcResourceType have been exhausted. |
Effect | The specified IOM resource has reached its limit. Some traffic may be affected. |
Recovery | Intervention may be required to recover resources. |
tmnxIomRsrcUsageHighLimitReached
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3252 |
Event name | tmnxIomRsrcUsageHighLimitReached |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.252 |
Default severity |
warning |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxIomRsrcUsageHighLimitReached notification is generated when the utilization of the IOM resource of type tmnxIomRsrcResourceType reaches or exceeds the high utilization threshold. |
Effect | The specified IOM resource is getting close to exhaustion. |
Recovery | There is no recovery required for this notification. |
tmnxIomRsrcUsageRecovered
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3254 |
Event name | tmnxIomRsrcUsageRecovered |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.254 |
Default severity |
minor |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxIomRsrcUsageRecovered notification is generated when the utilization of the IOM resource of type tmnxIomRsrcResourceType drops below the warning threshold. |
Effect | The utilization of the specified IOM resource has dropped below the warning threshold. |
Recovery | There is no recovery required for this notification. |
tmnxIPMacCpmFilterOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2183 |
Event name | tmnxIPMacCpmFilterOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.172 |
Default severity |
critical |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an IPv4 or MAC CPM Filter in overload. |
Cause | The tmnxIPMacCpmFilterOverload notification is generated when an IPv4 or MAC CPM Filter policy is in overload on an FP. |
Effect | The impacted IPv4 or MAC CPM Filter policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted IPv4 or MAC CPM Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPMacCpmFilterOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2184 |
Event name | tmnxIPMacCpmFilterOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.173 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an IPv4 or MAC CPM Filter in overload. |
Cause | The tmnxIPMacCpmFilterOverloadClear notification is generated when IPv4 or MAC CPM Filter policies are no longer in overload on an FP. |
Effect | The IPv4 or MAC CPM Filter policies on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPMacFilterEgrNearFull
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2277 |
Event name | tmnxIPMacFilterEgrNearFull |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.199 |
Default severity |
minor |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has egress IPv4 or MAC ACL Filters at near full utilization. |
Cause | The tmnxIPMacFilterEgrNearFull notification is generated when an egress IPv4 or MAC ACL Filter policies are near full utilization on an FP. |
Effect | There is no operational impact due to this event. |
Recovery | None required. |
tmnxIPMacFilterEgrNearFullClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2278 |
Event name | tmnxIPMacFilterEgrNearFullClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.200 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has egress IPv4 or MAC ACL Filters near full utilization. |
Cause | The tmnxIPMacFilterEgrNearFullClear notification is generated when egress IPv4 or MAC ACL Filter policies are no longer near full utilization on an FP. |
Effect | There is no operational impact due to this event. |
Recovery | None required. |
tmnxIPMacFilterEgrOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2177 |
Event name | tmnxIPMacFilterEgrOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.166 |
Default severity |
critical |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an egress IPv4 or MAC ACL Filter in overload. |
Cause | The tmnxIPMacFilterEgrOverload notification is generated when an egress IPv4 or MAC ACL Filter policy is in overload on an FP. |
Effect | The impacted egress IPv4 or MAC ACL Filter policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted egress IPv4 or MAC ACL Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPMacFilterEgrOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2178 |
Event name | tmnxIPMacFilterEgrOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.167 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an egress IPv4 or MAC ACL Filter in overload. |
Cause | The tmnxIPMacFilterEgrOverloadClear notification is generated when egress IPv4 or MAC ACL Filter policies are no longer in overload on an FP. |
Effect | The egress IPv4 or MAC ACL Filter policies on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPMacFilterIngNearFull
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2275 |
Event name | tmnxIPMacFilterIngNearFull |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.197 |
Default severity |
minor |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has ingress IPv4 or MAC ACL Filters at near full utilization. |
Cause | The tmnxIPMacFilterIngNearFull notification is generated when an ingress IPv4 or MAC ACL Filter policies are near full utilization on an FP. |
Effect | There is no operational impact due to this event. |
Recovery | None required. |
tmnxIPMacFilterIngNearFullClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2276 |
Event name | tmnxIPMacFilterIngNearFullClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.198 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has ingress IPv4 or MAC ACL Filters at near full utilization. |
Cause | The tmnxIPMacFilterIngNearFullClear notification is generated when ingress IPv4 or MAC ACL Filter policies are no longer near full utilization on an FP. |
Effect | There is no operational impact due to this event. |
Recovery | None required. |
tmnxIPMacFilterIngOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2175 |
Event name | tmnxIPMacFilterIngOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.164 |
Default severity |
critical |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an ingress IPv4 or MAC ACL Filter in overload. |
Cause | The tmnxIPMacFilterIngOverload notification is generated when an ingress IPv4 or MAC ACL Filter policy is in overload on an FP. |
Effect | The impacted ingress IPv4 or MAC ACL Filter policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted ingress IPv4 or MAC ACL Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPMacFilterIngOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2176 |
Event name | tmnxIPMacFilterIngOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.165 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an ingress IPv4 or MAC ACL Filter in overload. |
Cause | The tmnxIPMacFilterIngOverloadClear notification is generated when ingress IPv4 or MAC ACL Filter policies are no longer in overload on an FP. |
Effect | The ingress IPv4 or MAC ACL Filter policies on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPMacQosIngOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2167 |
Event name | tmnxIPMacQosIngOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.156 |
Default severity |
major |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an ingress QoS policy with IPv4 or MAC criteria entries in overload. |
Cause | The tmnxIPMacQosIngOverload notification is generated when an ingress QoS policy is in overload on an FP due to its configured IPv4 or MAC criteria entries. |
Effect | The impacted IPv4 or MAC criteria entries in the ingress QoS policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted ingress QoS policy, policy entries, and FPs using the appropriate tools commands. Remove or modify the policy criteria entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPMacQosIngOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2168 |
Event name | tmnxIPMacQosIngOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.157 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an ingress QoS policy with IPv4 or MAC criteria entries in overload. |
Cause | The tmnxIPMacQosIngOverloadClear notification is generated when ingress QoS policies are no longer in overload on an FP. |
Effect | The IPv4 or MAC criteria entries in the ingress QoS policies on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPQosEgrOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2169 |
Event name | tmnxIPQosEgrOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.158 |
Default severity |
major |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an egress QoS policy with IPv4 criteria entries in overload. |
Cause | The tmnxIPQosEgrOverload notification is generated when an egress QoS policy is in overload on an FP due to its configured IPv4 criteria entries. |
Effect | The impacted IPv4 criteria entries in the egress QoS policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted egress QoS policy, policy entries, and FPs using the appropriate tools commands. Remove or modify the policy criteria entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPQosEgrOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2170 |
Event name | tmnxIPQosEgrOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.159 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an egress QoS policy with IPv4 criteria entries in overload. |
Cause | The tmnxIPQosEgrOverloadClear notification is generated when egress QoS policies are no longer in overload on an FP. |
Effect | The IPv4 criteria entries in the egress QoS policy on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPsecIsaGrpActiveIsaChgd
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2062 |
Event name | tmnxIPsecIsaGrpActiveIsaChgd |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.50 |
Default severity |
minor |
Source stream | main |
Message format string | Active ISA changed to $tmnxIPsecIsaGrpActiveIsa$ for IPsec ISA group $tmnxIPsecIsaGrpId$ where primary ISA is $tmnxIPsecIsaGrpPrimaryIsa$ and Backup ISA is $tmnxIPsecIsaGrpBackupIsa$ |
Cause | The tmnxIPsecIsaGrpActiveIsaChgd notification is generated when a change in the active ISA (Integrated Service Adaptor) occurs in an IPsec ISA module group. |
Effect | N/A |
Recovery | N/A |
tmnxIPsecIsaGrpTnlHighWMark
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2066 |
Event name | tmnxIPsecIsaGrpTnlHighWMark |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.54 |
Default severity |
minor |
Source stream | main |
Message format string | Number of tunnels for an IPsec ISA module for the group $tmnxIPsecIsaGrpId$ has reached to the high watermark which is 95% of the maximum limit $tmnxIPsecIsaGrpMaxTunnels$. |
Cause | The number of tunnels for an IPsec ISA (Integrated Service Adaptor) module has reached to the high watermark which is 95% of the maximum limit. |
Effect | N/A |
Recovery | N/A |
tmnxIPsecIsaGrpTnlLowWMark
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2065 |
Event name | tmnxIPsecIsaGrpTnlLowWMark |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.53 |
Default severity |
minor |
Source stream | main |
Message format string | Number of tunnels for an IPsec ISA module for the group $tmnxIPsecIsaGrpId$ has dropped to the low watermark which is 90% of the maximum limit $tmnxIPsecIsaGrpMaxTunnels$. |
Cause | The number of tunnels for an IPsec ISA (Integrated Service Adaptor) module has dropped to the low watermark which is 90% of the maximum limit. |
Effect | N/A |
Recovery | N/A |
tmnxIPsecIsaGrpTnlMax
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2067 |
Event name | tmnxIPsecIsaGrpTnlMax |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.55 |
Default severity |
minor |
Source stream | main |
Message format string | Number of tunnels for an IPsec ISA module for the group $tmnxIPsecIsaGrpId$ has reached the maximum limit $tmnxIPsecIsaGrpMaxTunnels$. |
Cause | The number of tunnels for an IPsec ISA (Integrated Service Adaptor) module has reached the maximum limit. |
Effect | N/A |
Recovery | N/A |
tmnxIPsecIsaGrpUnableToSwitch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2064 |
Event name | tmnxIPsecIsaGrpUnableToSwitch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.52 |
Default severity |
minor |
Source stream | main |
Message format string | IPsec ISA $tmnxIPsecIsaGrpActiveIsa$ for group $tmnxIPsecIsaGrpId$ is unable to switch due to lack of resources on the destination MDA |
Cause | IPsec ISA group is unable to switch due to lack of resources on the destination MDA. |
Effect | In such an event the IPsec ISA group is left without an active MDA and the tmnxIPsecIsaGrpOperState is set to 'outOfService'. |
Recovery | Recovery is possible by releasing resources and performing a shutdown/no shutdown operation to bring up the ISA group. |
tmnxIPv6CpmFilterOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2185 |
Event name | tmnxIPv6CpmFilterOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.174 |
Default severity |
critical |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an IPv6 CPM Filter in overload. |
Cause | The tmnxIPv6CpmFilterOverload notification is generated when an IPv6 CPM Filter policy is in overload on an FP. |
Effect | The impacted IPv6 CPM Filter policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted IPv6 CPM Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPv6CpmFilterOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2186 |
Event name | tmnxIPv6CpmFilterOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.175 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an IPv6 CPM Filter in overload. |
Cause | The tmnxIPv6CpmFilterOverloadClear notification is generated when IPv6 CPM Filter policies are no longer in overload on an FP. |
Effect | The IPv6 CPM Filter policies on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPv6FilterEgrNearFull
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2281 |
Event name | tmnxIPv6FilterEgrNearFull |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.203 |
Default severity |
minor |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has egress IPv6 ACL Filters at near full utilization. |
Cause | The tmnxIPv6FilterEgrNearFull notification is generated when an egress IPv6 ACL Filter policies are near full utilization on an FP. |
Effect | There is no operational impact due to this event. |
Recovery | None required. |
tmnxIPv6FilterEgrNearFullClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2282 |
Event name | tmnxIPv6FilterEgrNearFullClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.204 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has egress IPv6 ACL Filters at near full utilization. |
Cause | The tmnxIPv6FilterEgrNearFullClear notification is generated when egress IPv6 ACL Filter policies are no longer near full utilization on an FP. |
Effect | There is no operational impact due to this event. |
Recovery | None required. |
tmnxIPv6FilterEgrOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2181 |
Event name | tmnxIPv6FilterEgrOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.170 |
Default severity |
critical |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an egress IPv6 ACL Filter in overload. |
Cause | The tmnxIPv6FilterEgrOverload notification is generated when an egress IPv6 ACL Filter policy is in overload on an FP. |
Effect | The impacted egress IPv6 ACL Filter policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted egress IPv6 ACL Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or changed the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPv6FilterEgrOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2182 |
Event name | tmnxIPv6FilterEgrOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.171 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an egress IPv6 ACL Filter in overload. |
Cause | The tmnxIPv6FilterEgrOverloadClear notification is generated when egress IPv6 ACL Filter policies are no longer in overload on an FP. |
Effect | The egress IPv6 ACL Filter policies on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPv6FilterIngNearFull
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2279 |
Event name | tmnxIPv6FilterIngNearFull |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.201 |
Default severity |
minor |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has ingress IPv6 ACL Filters at near full utilization. |
Cause | The tmnxIPv6FilterIngNearFull notification is generated when an ingress IPv6 ACL Filter policies are near full utilization on an FP. |
Effect | There is no operational impact due to this event. |
Recovery | None required. |
tmnxIPv6FilterIngNearFullClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2280 |
Event name | tmnxIPv6FilterIngNearFullClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.202 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has ingress IPv6 ACL Filters at near full utilization. |
Cause | The tmnxIPv6FilterIngNearFullClear notification is generated when ingress IPv6 ACL Filter policies are no longer near full utilization on an FP. |
Effect | There is no operational impact due to this event. |
Recovery | None required. |
tmnxIPv6FilterIngOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2179 |
Event name | tmnxIPv6FilterIngOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.168 |
Default severity |
critical |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an ingress IPv6 ACL Filter in overload. |
Cause | The tmnxIPv6FilterIngOverload notification is generated when an ingress IPv6 ACL Filter policy is in overload on a FP. |
Effect | The impacted ingress IPv6 ACL Filter policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted ingress IPv6 ACL Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPv6FilterIngOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2180 |
Event name | tmnxIPv6FilterIngOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.169 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an ingress IPv6 ACL Filter in overload. |
Cause | The tmnxIPv6FilterIngOverloadClear notification is generated when ingress IPv6 ACL Filter policies are no longer in overload on an FP. |
Effect | The ingress IPv6 ACL Filter policies on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPv6QosEgrOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2173 |
Event name | tmnxIPv6QosEgrOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.162 |
Default severity |
major |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an egress QoS policy with IPv6 criteria entries in overload. |
Cause | The tmnxIPv6QosEgrOverload notification is generated when an egress QoS policy is in overload on an FP due to its configured IPv6 criteria entries. |
Effect | The impacted IPv6 criteria entries in the egress QoS Policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted egress QoS policy, policy entries, and FPs using the appropriate tools commands. Remove or modify the policy criteria entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPv6QosEgrOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2174 |
Event name | tmnxIPv6QosEgrOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.163 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an egress QoS policy with IPv6 criteria entries in overload. |
Cause | The tmnxIPv6QosEgrOverloadClear notification is generated when egress QoS policies are no longer in overload on an FP. |
Effect | The IPv6 criteria entries in the egress QoS policy on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIPv6QosIngOverload
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2171 |
Event name | tmnxIPv6QosIngOverload |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.160 |
Default severity |
major |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an ingress QoS policy with IPv6 criteria entries in overload. |
Cause | The tmnxIPv6QosIngOverload notification is generated when an ingress QoS policy is in overload on an FP due to its configured IPv6 criteria entries. |
Effect | The impacted IPv6 criteria entries in the ingress QoS policy on the affected FP will not work as expected, because not all entries are programmed. |
Recovery | Identify the impacted ingress QoS policy, policy entries, and FPs using the appropriate tools commands. Remove or modify the policy criteria entries or change the policy assigned to the impacted FPs until the overload condition is cleared. |
tmnxIPv6QosIngOverloadClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2172 |
Event name | tmnxIPv6QosIngOverloadClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.161 |
Default severity |
cleared |
Source stream | main |
Message format string | Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an ingress QoS policy with IPv6 criteria entries in overload. |
Cause | The tmnxIPv6QosIngOverloadClear notification is generated when ingress QoS policies are no longer in overload on an FP. |
Effect | The IPv6 criteria entries in the ingress QoS policy on the affected FP will work as expected, because all entries are programmed. |
Recovery | No recovery required. |
tmnxIxrResourceExhausted
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2433 |
Event name | tmnxIxrResourceExhausted |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.298 |
Default severity |
critical |
Source stream | main |
Message format string | The $tmnxNotifIxrResource$ resources have been exhausted. |
Cause | The tmnxIxrResourceExhausted notification is generated when the utilization of the resource specified by tmnxNotifIxrResource has reached its limit. |
Effect | The utilization of the specified resource has reached its limit. |
Recovery | Intervention may be required to recover resources. |
tmnxIxrResourceExhaustedByOwner
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2436 |
Event name | tmnxIxrResourceExhaustedByOwner |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.301 |
Default severity |
critical |
Source stream | main |
Message format string | The $tmnxNotifIxrResource$ resources needed by $tmnxNotifIxrResourceOwner$ have been exhausted. Some $tmnxNotifIxrResourceOwner$ traffic may be affected. |
Cause |
The tmnxIxrResourceExhaustedByOwner notification is generated when the utilization of the resource specified by tmnxNotifIxrResource reached its limit for application specified by tmnxNotifIxrResourceOwner. |
Effect | Usage of the resource specified by tmnxNotifIxrResource reached its limit for application specified by tmnxNotifIxrResourceOwner. |
Recovery | Intervention may be required to recover resources. |
tmnxIxrResourceHighUsage
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2432 |
Event name | tmnxIxrResourceHighUsage |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.297 |
Default severity |
major |
Source stream | main |
Message format string | The $tmnxNotifIxrResource$ resources have reached or exceeded the high utilization threshold. Current utilization is $tmnxNotifIxrRsrcUtilPercentage$%%. |
Cause | The tmnxIxrResourceHighUsage notification is generated when the number of allocated resources reaches or exceeds the warning high limit. |
Effect | The specified resource is getting close to exhaustion. |
Recovery | There is no recovery required for this notification. |
tmnxIxrResourceHighUsageByOwner
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2435 |
Event name | tmnxIxrResourceHighUsageByOwner |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.300 |
Default severity |
major |
Source stream | main |
Message format string | The $tmnxNotifIxrResource$ resources needed by $tmnxNotifIxrResourceOwner$ have reached or exceeded the high utilization threshold. Current utilization is $tmnxNotifIxrRsrcUtilPercentage$%%. |
Cause | The tmnxIxrResourceHighUsageByOwner notification is generated when the number of allocated resources by an owner reaches or exceeds the warning high limit. |
Effect | The specified application is getting close to its maximal usage of the specified resource. |
Recovery | There is no recovery required for this notification. |
tmnxIxrResourceRecovered
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2434 |
Event name | tmnxIxrResourceRecovered |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.299 |
Default severity |
minor |
Source stream | main |
Message format string | The $tmnxNotifIxrResource$ resources have dropped below the warning utilization threshold. Current utilization is $tmnxNotifIxrRsrcUtilPercentage$%%. |
Cause | The tmnxIxrResourceRecovered notification is generated when the number of allocated resources drops below the warning threshold. This trap is generated only if the tmnxIxrResourceHighUsage notification or the tmnxIxrResourceExhausted notification had been generated. |
Effect | The utilization of the specified resource has dropped below the warning threshold. |
Recovery | There is no recovery required for this notification. |
tmnxIxrResourceRecoveredByOwner
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2437 |
Event name | tmnxIxrResourceRecoveredByOwner |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.302 |
Default severity |
minor |
Source stream | main |
Message format string | The $tmnxNotifIxrResource$ resources needed by $tmnxNotifIxrResourceOwner$ have dropped below the warning utilization threshold. Current utilization is $tmnxNotifIxrResourceOwner$%%. |
Cause | The tmnxIxrResourceRecoveredByOwner notification is generated when the number of allocated resources by the specified application drops below the warning threshold. This trap is generated only if the tmnxIxrResourceHighUsageByOwner notification or the tmnxIxrResourceExhaustedByOwner notification had been generated. |
Effect | The utilization of the specified resource by a given application has dropped below the warning threshold. |
Recovery | There is no recovery required for this notification. |
tmnxMDAIsaTunnelGroupChange
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2083 |
Event name | tmnxMDAIsaTunnelGroupChange |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.71 |
Default severity |
minor |
Source stream | main |
Message format string | MDA $tmnxCardSlotNum$/$tmnxMDASlotNum$ is $tmnxMDAIsaTunnelGroupInUse$ active in the ISA tunnel-group $tmnxMDAIsaTunnelGroup$ |
Cause | The tmnxMDAIsaTunnelGroupChange notification is generated when IPsec ISA (Integrated Service Adaptor) tunnel-group in-use for the MDA changes value. |
Effect | There is no operational impact due to this event. |
Recovery | N/A |
tmnxPeBootloaderVersionMismatch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2027 |
Event name | tmnxPeBootloaderVersionMismatch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.35 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Bootloader version mismatch - expected software version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$ |
Cause | Generated when there is a mismatch between the CPM and boot loader versions. tmnxChassisNotifyHwIndex identifies the CPM card. tmnxChassisNotifyMismatchedVer contains the mismatched version of bootloader and tmnxHwSoftwareCodeVersion contains the expected version of the bootloader. |
Effect | N/A |
Recovery | N/A |
tmnxPeBootromVersionMismatch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2028 |
Event name | tmnxPeBootromVersionMismatch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.36 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Bootrom version mismatch - expected version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$ |
Cause | Generated when there is a mismatch between the boot rom versions. tmnxChassisNotifyHwIndex identifies the IOM card. tmnxChassisNotifyMismatchedVer contains the mismatched version of bootrom and tmnxHwSoftwareCodeVersion contains the expected version of the bootrom. |
Effect | N/A |
Recovery | N/A |
tmnxPeFirmwareVersionWarning
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2082 |
Event name | tmnxPeFirmwareVersionWarning |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.70 |
Default severity |
warning |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Firmware version $tmnxHwFirmwareCodeVersion$ is compatible but not the latest. Hard reset the MDA/IMM to upgrade to the most recent firmware if desired. |
Cause | Generated when a card is running compatible yet older firmware than the firmware associated with the current software release. tmnxChassisNotifyHwIndex identifies the card. The tmnxHwFirmwareCodeVersion object will contain the programmed the firmware version. |
Effect | N/A |
Recovery | N/A |
tmnxPeFPGAVersionMismatch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2029 |
Event name | tmnxPeFPGAVersionMismatch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.37 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : FPGA version mismatch - expected version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$ |
Cause | Generated when there is a mismatch between the FPGA versions. tmnxChassisNotifyHwIndex identifies the IOM card. tmnxChassisNotifyMismatchedVer contains the mismatched version of FPGA and tmnxHwSoftwareCodeVersion contains the expected version of the FPGA. |
Effect | N/A |
Recovery | N/A |
tmnxPeKernelVersionMismatch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2221 |
Event name | tmnxPeKernelVersionMismatch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.232 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Kernel version mismatch - expected software version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$ |
Cause | This notification is generated when there is a mismatch between the software version of the host kernel software and the CPM software. This may occur if the user updates the system software without following the recommended software upgrade procedures. The object tmnxChassisNotifyHwIndex identifies the CPM card. The object tmnxChassisNotifyMismatchedVer contains the version of the host kernel software and tmnxHwSoftwareCodeVersion contains the version of the CPM software. This notification is only applicable to systems that use both host kernel software and CPM software, such as the 7705 SAR-Hm and the 7250 IXR-s. |
Effect | Although the system may appear to work properly, the behavior of the system in this state is undefined. Using mismatched versions of host kernel software and CPM software is not supported. |
Recovery | Follow the recommended software upgrade procedures to update the host kernel software and CPM software to the desired software release. |
tmnxPeSoftwareLoadFailed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2026 |
Event name | tmnxPeSoftwareLoadFailed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.34 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Failed to load software from $tmnxChassisNotifySoftwareLocation$ |
Cause | Generated when the CPM fails to load the software from a specified location. tmnxChassisNotifyHwIndex identifies the card for which the software load failed and tmnxChassisNotifySoftwareLocation contains the location from where the software load was attempted. |
Effect | N/A |
Recovery | N/A |
tmnxPeSoftwareVersionMismatch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2025 |
Event name | tmnxPeSoftwareVersionMismatch |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.16 |
Default severity |
major |
Source stream | main |
Message format string | Class $tmnxHwClass$ : Software version mismatch - expected software version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$ |
Cause | Generated when there is a mismatch between software versions of the active CPM and standby CPM or the CPM and IOM. tmnxChassisNotifyHwIndex identifies the mismatched CPM/IOM card and tmnxChassisNotifyMismatchedVer will contain the version of the mismatched card. The tmnxHwSoftwareCodeVersion object will contain the expected version. |
Effect | N/A |
Recovery | N/A |
tmnxPhysChassisFilterDoorClosed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2195 |
Event name | tmnxPhysChassisFilterDoorClosed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.194 |
Default severity |
cleared |
Source stream | main |
Message format string | Filter door is closed |
Cause |
The tmnxPhysChassisFilterDoorClosed notification is generated when the filter door is present and closed. |
Effect | The power shelves are protected by the closed door. |
Recovery | No recovery required. |
tmnxPhysChassisFilterDoorOpen
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2194 |
Event name | tmnxPhysChassisFilterDoorOpen |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.193 |
Default severity |
minor |
Source stream | main |
Message format string | Filter door is missing or open |
Cause |
The tmnxPhysChassisFilterDoorOpen notification is generated when the filter door is either open or not present. |
Effect | Power shelf protection may be compromised. |
Recovery | If the filter door is not installed, install it. Close the filter door. |
tmnxPhysChassisPCMInputFeed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2165 |
Event name | tmnxPhysChassisPCMInputFeed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.154 |
Default severity |
minor |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ pcm $tmnxPhysChassisPCMId$ $tmnxPhysChassisPCMInFeedDown$not supplying power. |
Cause |
The tmnxPhysChassisPCMInputFeed notification is generated if any one of the input feeds for a given PCM has gone offline. |
Effect | There is an increased risk of system power brown-outs or black-outs. |
Recovery | Restore all of the input feeds that are not supplying power. |
tmnxPhysChassisPCMInputFeedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2166 |
Event name | tmnxPhysChassisPCMInputFeedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.155 |
Default severity |
cleared |
Source stream | main |
Message format string | The input feeds for chassis $tmnxPhysChassisNum$ pcm $tmnxPhysChassisPCMId$ are supplying power. |
Cause | The tmnxPhysChassisPCMInputFeedClr notification is generated when the last of the missing input feeds for a given PCM has been brought back online. |
Effect | All PCM input feeds are supplying power. |
Recovery | No recovery required. |
tmnxPhysChassisPMInputFeed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2192 |
Event name | tmnxPhysChassisPMInputFeed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.191 |
Default severity |
minor |
Source stream | main |
Message format string | Power module $tmnxHwIndex$ $tmnxPhysChassisPMInputFeedDown$not supplying power. |
Cause | The tmnxPhysChassisPMInputFeed notification is generated if any one of the input feeds for a given power module is not supplying power. |
Effect | There is an increased risk of system power brownouts or blackouts. |
Recovery | Restore all of the input feeds that are not supplying power. |
tmnxPhysChassisPMInputFeedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2193 |
Event name | tmnxPhysChassisPMInputFeedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.192 |
Default severity |
cleared |
Source stream | main |
Message format string | The input feeds for power module $tmnxHwIndex$ are supplying power. |
Cause | The tmnxPhysChassPwrSupInputFeedClr notification is generated when the last of the missing input feeds has been brought back online. |
Effect | All power module input feeds are supplying power. |
Recovery | No recovery required. |
tmnxPhysChassisPMOutFail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2190 |
Event name | tmnxPhysChassisPMOutFail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.189 |
Default severity |
critical |
Source stream | main |
Message format string | Power module $tmnxHwIndex$ output failure |
Cause | The tmnxPhysChassisPMOutFail notification is generated when an output failure occurs on the power module. |
Effect | The power module is no longer operational. |
Recovery | Insert a new power module. |
tmnxPhysChassisPMOutFailClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2191 |
Event name | tmnxPhysChassisPMOutFailClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.190 |
Default severity |
cleared |
Source stream | main |
Message format string | Power module $tmnxHwIndex$ output failure cleared |
Cause | The tmnxPhysChassisPMOutFailClr notification is generated when an output failure is cleared on the power module. |
Effect | The power module is operational again. |
Recovery | There is no recovery for this notification. |
tmnxPhysChassisPMOverTemp
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2196 |
Event name | tmnxPhysChassisPMOverTemp |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.195 |
Default severity |
critical |
Source stream | main |
Message format string | $tmnxHwIndex$ over temperature |
Cause | The tmnxPhysChassisPMOverTemp notification is generated when a power module's temperature surpasses the temperature threshold. |
Effect | The power module is no longer operational. |
Recovery | Check input feed and/or insert a new power module. |
tmnxPhysChassisPMOverTempClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2197 |
Event name | tmnxPhysChassisPMOverTempClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.196 |
Default severity |
cleared |
Source stream | main |
Message format string | $tmnxHwIndex$ over temperature cleared |
Cause | The tmnxPhysChassisPMOverTempClr notification is generated when a power module's temperature is reduced below the temperature threshold. |
Effect | The power module is operational again. |
Recovery | There is no recovery for this notification. |
tmnxPhysChassPwrSupInputFeed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2159 |
Event name | tmnxPhysChassPwrSupInputFeed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.146 |
Default severity |
minor |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ $tmnxPhysChassPowerSupInFeedDown$not supplying power. |
Cause |
The tmnxPhysChassPwrSupInputFeed notification is generated if any one of the input feeds for a given power supply is not supplying power. |
Effect | There is an increased risk of system power brown-outs or black-outs. |
Recovery | Restore all of the input feeds that are not supplying power. |
tmnxPhysChassPwrSupInputFeedClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2160 |
Event name | tmnxPhysChassPwrSupInputFeedClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.147 |
Default severity |
cleared |
Source stream | main |
Message format string | The input feeds for chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ are supplying power. |
Cause | The tmnxPhysChassPwrSupInputFeedClr notification is generated when the last of the missing input feeds has been brought back online. |
Effect | All power supply input feeds are supplying power. |
Recovery | No recovery required. |
tmnxPhysChassPwrSupPemACRect
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2157 |
Event name | tmnxPhysChassPwrSupPemACRect |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.144 |
Default severity |
minor |
Source stream | main |
Message format string | Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ $tmnxPhysChassPowerSupPemACRect$failed or missing. |
Cause |
The tmnxPhysChassPwrSupPemACRect notification is generated if any one of the AC rectifiers for a given power supply is in a failed state or is missing. |
Effect | There is an increased risk of the power supply failing, causing insufficient power to the system. |
Recovery | Bring the AC rectifiers back online. |
tmnxPhysChassPwrSupPemACRectClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2158 |
Event name | tmnxPhysChassPwrSupPemACRectClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.145 |
Default severity |
cleared |
Source stream | main |
Message format string | The chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ AC rectifiers are fully operational. |
Cause | The tmnxPhysChassPwrSupPemACRectClr notification is generated when the last of the failed or missing AC rectifiers has been brought back online. |
Effect | The power supply AC rectifiers are fully operational. |
Recovery | No recovery required. |
tmnxPhysChassPwrSupWrgFanDir
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2155 |
Event name | tmnxPhysChassPwrSupWrgFanDir |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.142 |
Default severity |
major |
Source stream | main |
Message format string | The $tmnxPhysChassPowerSupFanDir$ fan direction for chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ is not supported. |
Cause | The tmnxPhysChassPwrSupWrgFanDir notification is generated when the airflow direction of the power supply's fan is incorrect. |
Effect | The power supply is not cooling properly and may overheat. |
Recovery | Replace the power supply with one that has the proper fan direction. |
tmnxPhysChassPwrSupWrgFanDirClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2156 |
Event name | tmnxPhysChassPwrSupWrgFanDirClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.143 |
Default severity |
cleared |
Source stream | main |
Message format string | The fan direction for chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ has been corrected. |
Cause | The tmnxPhysChassPwrSupWrgFanDirClr notification is generated when the airflow direction of the power supply's fan is corrected. |
Effect | The fan is cooling the power supply in the proper direction. |
Recovery | No recovery required. |
tmnxPlcyAcctPlcrPoolExcResource
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2231 |
Event name | tmnxPlcyAcctPlcrPoolExcResource |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.242 |
Default severity |
minor |
Source stream | main |
Message format string | Policer Resource usage on card $tmnxCardSlotNum$ and forwarding plane $tmnxFPNum$ exceeds 95 percent of the policer limit. Total policer resource used is '$tmnxFPPlcyAcctPolicerInUse$' and the limit is ' $tmnxFPPlcyAcctPolicerLimit$' |
Cause | The tmnxPlcyAcctPlcrPoolExcResource notification is generated when the number of in-use policer resource usage as specified by tmnxFPPlcyAcctPolicerInUse exceeds 95 percent of the policer limit as specified by tmnxFPPlcyAcctPolicerLimit. |
Effect | The affected device may not provide accurate and complete statistics. |
Recovery | There is no recovery required for this notification. |
tmnxPlcyAcctPlcrPoolLowResource
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2232 |
Event name | tmnxPlcyAcctPlcrPoolLowResource |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.243 |
Default severity |
minor |
Source stream | main |
Message format string | Policer Resource usage on card $tmnxCardSlotNum$ and forwarding plane $tmnxFPNum$ is below 85 percent of the policer limit. Total policer resource used is '$tmnxFPPlcyAcctPolicerInUse$' and the limit is ' $tmnxFPPlcyAcctPolicerLimit$' |
Cause | The tmnxPlcyAcctPlcrPoolLowResource notification is generated when the number of in-use policer resource as specified by tmnxFPPlcyAcctPolicerInUse is below 85 percent of the policer limit as specified by tmnxFPPlcyAcctPolicerLimit. |
Effect | The configured policer limit is cleared when the number of in-use policer resources falls below 85 percent of the policer limit. |
Recovery | There is no recovery required for this notification. |
tmnxPlcyAcctStatsEventOvrflw
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2120 |
Event name | tmnxPlcyAcctStatsEventOvrflw |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.107 |
Default severity |
minor |
Source stream | main |
Message format string | Policy Accounting FP log event overflow occurred on card $tmnxChassisNotifyCardSlotNum$ at $tmnxPlcyAcctTimeEventOccured$. |
Cause | The tmnxPlcyAcctStatsEventOvrflw notification is generated when tmnxPlcyAcctStatsPoolExcResource and tmnxPlcyAcctStatsPoolLowResource occur more than 200 times because of resource usage fluctuation. The IOM raises the final trap to indicate overflow and stops logging traps. |
Effect | Some FP notifications configured on the card may not be received. |
Recovery | Notifications will resume once the Overflow clear is set. |
tmnxPlcyAcctStatsEventOvrflwClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2119 |
Event name | tmnxPlcyAcctStatsEventOvrflwClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.106 |
Default severity |
minor |
Source stream | main |
Message format string | $tmnxPlcyAcctMissingNotifCount$ Policy Accounting FP log events were dropped in the last event throttling interval on card $tmnxChassisNotifyCardSlotNum$ at $tmnxPlcyAcctTimeEventOccured$. |
Cause |
The tmnxPlcyAcctStatsEventOvrflwClr notification is generated when the CPM polls the IOM for traps and the overflow is cleared by logging an overflow-clear on a particular card. |
Effect | Notifications are received again since the event throttling has ended. |
Recovery | There is no recovery for this notification. |
tmnxPlcyAcctStatsPoolExcResource
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2117 |
Event name | tmnxPlcyAcctStatsPoolExcResource |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.104 |
Default severity |
minor |
Source stream | main |
Message format string | Stats Resource usage on card $tmnxCardSlotNum$ and forwarding plane $tmnxFPNum$ exceeds 95 percent of the stats pool limit. Total stats resource used is '$tmnxFPPlcyAcctStatsInUse$' and the limit is ' $tmnxFPPlcyAcctStatsPool$' |
Cause | The tmnxPlcyAcctStatsPoolExcResource notification is generated when the number of in-use stats resource usage as specified by tmnxFPPlcyAcctStatsInUse exceeds 95 percent of the stats pool limit as specified by tmnxFPPlcyAcctStatsPool. |
Effect | The affected device may not provide accurate and complete statistics. |
Recovery | There is no recovery required for this notification. |
tmnxPlcyAcctStatsPoolLowResource
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2118 |
Event name | tmnxPlcyAcctStatsPoolLowResource |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.105 |
Default severity |
minor |
Source stream | main |
Message format string | Stats Resource usage on card $tmnxCardSlotNum$ and forwarding plane $tmnxFPNum$ is below 85 percent of the stats pool limit. Total stats resource used is '$tmnxFPPlcyAcctStatsInUse$' and the limit is ' $tmnxFPPlcyAcctStatsPool$' |
Cause | The tmnxPlcyAcctStatsPoolLowResource notification is generated when the number of in-use stats resource as specified by tmnxFPPlcyAcctStatsInUse is below 85 percent of the stats pool limit as specified by tmnxFPPlcyAcctStatsPool. |
Effect | The configured stats pool limit is cleared when the number of in-use stats resources falls below 85 percent of the stats pool limit. |
Recovery | There is no recovery required for this notification. |
tmnxPowerShelfCommsDown
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 6002 |
Event name | tmnxPowerShelfCommsDown |
SNMP notification prefix and OID |
TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.2 |
Default severity |
minor |
Source stream | main |
Message format string | $tmnxHwIndex$ lost communication with $tmnxCpmPowerShelfCommsFail$ |
Cause | The tmnxPowerShelfCommsDown is generated when there is a loss of communications with the power shelf controller. |
Effect | If there is a power failure, it will not be detected since the power modules cannot be polled. The system will continue to report the state of the power modules as they were when last seen. |
Recovery | Correct the power shelf controller communications problem. |
tmnxPowerShelfCommsUp
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 6003 |
Event name | tmnxPowerShelfCommsUp |
SNMP notification prefix and OID |
TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.3 |
Default severity |
cleared |
Source stream | main |
Message format string | Re-established communications to $tmnxHwIndex$ |
Cause | The tmnxPowerShelfCommsUp notification is generated when a loss of communications with the power shelf controller has been resolved. |
Effect | Power failures can be detected. |
Recovery |
No recovery required. |
tmnxPowerShelfInputPwrModeSwitch
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
6001 |
Event name | tmnxPowerShelfInputPwrModeSwitch |
SNMP notification prefix and OID | TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.1 |
Default severity | minor |
Source stream |
main |
Message format string | $tmnxHwIndex$ input power mode switched to $tmnxPowerShelfInputPowerMode$A |
Cause | The tmnxPowerShelfInputPwrModeSwitch is generated when tmnxPowerShelfInputPowerMode has changed value. |
Effect | No effect. |
Recovery |
No recovery required. |
tmnxPowerShelfOutputStatusDown
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
6005 |
Event name | tmnxPowerShelfOutputStatusDown |
SNMP notification prefix and OID | TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.5 |
Default severity | minor |
Source stream |
main |
Message format string | $tmnxHwIndex$ output status switched to $tmnxPowerShelfOutputStatus$ |
Cause | The tmnxPowerShelfOutputStatusSwitch is generated when the physical output switch on the power shelf is set to Standby. |
Effect | The power output from the identified power shelf is switched off and does not supply power to the system. |
Recovery | Set output switch to On to restore power output. |
tmnxPowerShelfOutputStatusSwitch
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 6004 |
Event name | tmnxPowerShelfOutputStatusSwitch |
SNMP notification prefix and OID |
TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.4 |
Default severity |
minor |
Source stream | main |
Message format string | $tmnxHwIndex$ output status switched to $tmnxPowerShelfOutputStatus$ |
Cause | The tmnxPowerShelfOutputStatusSwitch is generated when tmnxPowerShelfOutputStatus has changed value. |
Effect | No effect. |
Recovery |
No recovery required. |
tmnxPowerShelfOutputStatusUp
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
6006 |
Event name | tmnxPowerShelfOutputStatusUp |
SNMP notification prefix and OID | TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.6 |
Default severity | minor |
Source stream |
main |
Message format string | $tmnxHwIndex$ output status switched to $tmnxPowerShelfOutputStatus$ |
Cause | The tmnxPowerShelfOutputStatusSwitch is generated when the physical output switch on the power shelf is set to On. |
Effect | Power output from the identified power shelf is enabled and now supplies power to the system. |
Recovery | No recovery required. |
tmnxPowerSupplyFanFailed
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2430 |
Event name | tmnxPowerSupplyFanFailed |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.295 |
Default severity |
minor |
Source stream | main |
Message format string | Power supply $tmnxHwIndex$ fan failed |
Cause | The tmnxPowerSupplyFanFailed notification is generated when a fan within a particular power-supply has ceased to function normally. |
Effect | Cooling to the power-supply may be reduced, potentially leading to overheating. |
Recovery | The power-supply should be replaced by one with fully-functioning fan elements. |
tmnxPowerSupplyFanFailedClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2431 |
Event name | tmnxPowerSupplyFanFailedClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.296 |
Default severity |
minor |
Source stream | main |
Message format string | Power supply $tmnxHwIndex$ fan failure cleared |
Cause | The tmnxPowerSupplyFanFailedClear notification is generated when the fan component of a power-supply has been restored to normal operation. |
Effect | N/A |
Recovery | N/A |
tmnxRedPrimaryCPMFail
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2012 |
Event name | tmnxRedPrimaryCPMFail |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.21 |
Default severity |
critical |
Source stream | main |
Message format string | Active CPM failed |
Cause |
Generated when the primary CPM fails. |
Effect | N/A |
Recovery | N/A |
tmnxSasAlarminput1StateChanged
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3001 |
Event name | tmnxSasAlarminput1StateChanged |
SNMP notification prefix and OID |
TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSasAlarmInputNotifications.1 |
Default severity |
major |
Source stream | main |
Message format string | Alarm Input "$tmnxSasAlarmInputDescription$" has changed status "$tmnxSasAlarmInputNotifyMessage$" |
Cause | A tmnxSasAlarminput1StateChanged notification is sent when status of the alarm input on pin one(1) changes. When this notification is sent, the field tmnxSasAlarmInputNotifyMessage is populated with either the tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the tmnxSasAlarmInputClearMessage when the alarm is cleared. The trigger or clear actions depend on the polarity of the input as defined in tmnxSasAlarmInputPolarity. |
Effect | A desirable or undesirable event has occurred in the external equipment connected to the alarm input. Hence the characteristics of effect and the associated risks vary depending on the nature of the external equipment being monitored over the alarm input. |
Recovery | Check the external equipment, connected to the alarm input pin one(1), that resulted in this alarm and rectify the problem. |
tmnxSasAlarminput2StateChanged
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3002 |
Event name | tmnxSasAlarminput2StateChanged |
SNMP notification prefix and OID |
TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSasAlarmInputNotifications.2 |
Default severity |
major |
Source stream | main |
Message format string | Alarm Input "$tmnxSasAlarmInputDescription$" has changed status "$tmnxSasAlarmInputNotifyMessage$" |
Cause | A tmnxSasAlarminput2StateChanged notification is sent when status of the alarm input on pin two(2) changes. When this notification is sent, the field tmnxSasAlarmInputNotifyMessage is populated with either the tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the tmnxSasAlarmInputClearMessage when the alarm is cleared. The trigger or clear actions depend on the polarity of the input as defined in tmnxSasAlarmInputPolarity. |
Effect | A desirable or undesirable event has occurred in the external equipment connected to the alarm input. Hence the characteristics of effect and the associated risks vary depending on the nature of the external equipment being monitored over the alarm input. |
Recovery | Check the external equipment, connected to the alarm input pin two(2), that resulted in this alarm and rectify the problem. |
tmnxSasAlarminput3StateChanged
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3003 |
Event name | tmnxSasAlarminput3StateChanged |
SNMP notification prefix and OID |
TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSasAlarmInputNotifications.3 |
Default severity |
major |
Source stream | main |
Message format string | Alarm Input "$tmnxSasAlarmInputDescription$" has changed status "$tmnxSasAlarmInputNotifyMessage$" |
Cause | A tmnxSasAlarminput3StateChanged notification is sent when status of the alarm input on pin three(3) changes. When this notification is sent, the field tmnxSasAlarmInputNotifyMessage is populated with either the tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the tmnxSasAlarmInputClearMessage when the alarm is cleared. The trigger or clear actions depend on the polarity of the input as defined in tmnxSasAlarmInputPolarity. |
Effect | A desirable or undesirable event has occurred in the external equipment connected to the alarm input. Hence the characteristics of effect and the associated risks vary depending on the nature of the external equipment being monitored over the alarm input. |
Recovery | Check the external equipment, connected to the alarm input pin three(3), that resulted in this alarm and rectify the problem. |
tmnxSasAlarminput4StateChanged
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 3004 |
Event name | tmnxSasAlarminput4StateChanged |
SNMP notification prefix and OID |
TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSasAlarmInputNotifications.4 |
Default severity |
major |
Source stream | main |
Message format string | Alarm Input "$tmnxSasAlarmInputDescription$" has changed status "$tmnxSasAlarmInputNotifyMessage$" |
Cause | A tmnxSasAlarminput4StateChanged notification is sent when status of the alarm input on pin four(4) changes. When this notification is sent, the field tmnxSasAlarmInputNotifyMessage is populated with either the tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the tmnxSasAlarmInputClearMessage when the alarm is cleared. The trigger or clear actions depend on the polarity of the input as defined in tmnxSasAlarmInputPolarity. |
Effect | A desirable or undesirable event has occurred in the external equipment connected to the alarm input. Hence the characteristics of effect and the associated risks vary depending on the nature of the external equipment being monitored over the alarm input. |
Recovery | Check the external equipment, connected to the alarm input pin four(4), that resulted in this alarm and rectify the problem. |
tmnxSfmIcPortDDMClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4026 |
Event name | tmnxSfmIcPortDDMClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.7 |
Default severity |
minor |
Source stream | main |
Message format string | SFM interconnect port SFF DDM $tmnxDDMLaneIdOrModule$ ($tmnxDDMFailedObject$) cleared |
Cause | The tmnxSfmIcPortDDMFailure notification is generated when an SFF in an SFM interconnect port that supports Digital Diagnostic Monitoring (DDM) clears a failed state. |
Effect | N/A |
Recovery | N/A |
tmnxSfmIcPortDDMFailure
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4025 |
Event name | tmnxSfmIcPortDDMFailure |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.6 |
Default severity |
minor |
Source stream | main |
Message format string | SFM interconnect port SFF DDM $tmnxDDMLaneIdOrModule$ ($tmnxDDMFailedObject$) raised |
Cause | The tmnxSfmIcPortDDMFailure notification is generated when an SFF in an SFM interconnect port that supports Digital Diagnostic Monitoring (DDM) enters a failed state. |
Effect | N/A |
Recovery | N/A |
tmnxSfmIcPortDegraded
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4027 |
Event name | tmnxSfmIcPortDegraded |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.8 |
Default severity |
minor |
Source stream | main |
Message format string | Switch fabric capacity associated with the SFM interconnect port is in a $tmnxSfmIcPortDegradeState$ state |
Cause | The tmnxSfmIcPortDegraded notification is generated when the system has detected a degradation of the switch fabric that is associated with a particular SFM interconnect port. The value of tmnxSfmIcPortDegradeState will reflect this condition by having a value that is NOT 'none (1)'. If the value of tmnxSfmIcPortDegradeState is 'degraded (2)' the SFM interconnect port can still carry some traffic but not at the full capacity of the port. The port and attached cable are not necessarily the cause of the degradation but are a likely cause. |
Effect | Switch fabric capacity on this port is reduced when tmnxSfmIcPortDegradeState is degraded. This may not be causing any impact to service because of redundancy in the fabric. |
Recovery | Although it may not be necessary to maintain full service, replacing the affected components may restore some fabric capacity." |
tmnxSfmIcPortDegradedClear
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4028 |
Event name | tmnxSfmIcPortDegradedClear |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.9 |
Default severity |
minor |
Source stream | main |
Message format string | Switch fabric capacity associated with the SFM interconnect port is not in a degraded state |
Cause | The tmnxSfmIcPortDegradedClear notification is generated when the switch fabric associated with the SFM interconnect port is not degraded. This occurs when the value of tmnxSfmIcPortDegradeState is 'none (1)'." |
Effect | N/A |
Recovery | N/A |
tmnxSfmIcPortDown
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4017 |
Event name | tmnxSfmIcPortDown |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.1 |
Default severity |
minor |
Source stream | main |
Message format string | Possible messages:
|
Cause | The tmnxSfmIcPortDown alarm is generated when the SFM interconnect port is not operational. The reason may be a cable connected incorrectly, a disconnected cable, a faulty cable, or a misbehaving SFM interconnect port or SFM card. |
Effect | This port can no longer be used as part of the user plane fabric between chassis. Other fabric paths may be available resulting in no loss of capacity. |
Recovery | A manual verification and testing of each SFM interconnect port is required to ensure fully functional operation. Physical replacement of cabling may be required. |
tmnxSfmIcPortSFFInserted
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 4019 |
Event name | tmnxSfmIcPortSFFInserted |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.3 |
Default severity |
minor |
Source stream | main |
Message format string | SFM interconnect port SFF inserted |
Cause |
The tmnxSfmIcPortSFFInserted notification is generated when the Small Form Factor (SFF) pluggable optical module (eg. CXP) is inserted into an SFM interconnect port. |
Effect | This event is for notification only. |
Recovery |
N/A |
tmnxSfmIcPortSFFRemoved
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
4020 |
Event name | tmnxSfmIcPortSFFRemoved |
SNMP notification prefix and OID | TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.4 |
Default severity | minor |
Source stream |
main |
Message format string | SFM interconnect port SFF removed |
Cause | The tmnxSfmIcPortSFFRemoved notification is generated when the SFF (eg. CXP) is removed from the SFM interconnect port. |
Effect | Removing the module will cause the port to go down. This port can no longer be used as part of the user plane fabric between chassis. Other fabric paths may be available resulting in no loss of capacity. |
Recovery | Insert a working SFF into the SFM interconnect port. |
tmnxSfmIcPortUp
Property name | Value |
---|---|
Application name | CHASSIS |
Event ID |
4018 |
Event name | tmnxSfmIcPortUp |
SNMP notification prefix and OID | TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.2 |
Default severity | minor |
Source stream |
main |
Message format string | SFM interconnect port is operational |
Cause | The tmnxSfmIcPortUp notification is generated when the SFM interconnect port is operational again. |
Effect | This port can now be used as part of the user plane fabric between chassis. |
Recovery | N/A |
tmnxSyncIfTimBITS2048khzUnsup
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2134 |
Event name | tmnxSyncIfTimBITS2048khzUnsup |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.123 |
Default severity |
major |
Source stream | main |
Message format string | The revision of $tmnxHwIndex$ does not meet the specifications to support the 2048kHz BITS interface type. |
Cause | The tmnxSyncIfTimBITS2048khzUnsup notification is generated when the value of tSyncIfTimingAdmBITSIfType is set to 'g703-2048khz (5)' and the CPM does not meet the specifications for the 2048kHz BITS output signal under G.703. |
Effect | The BITS input will not be used as the Sync reference and the 2048kHz BITS output signal generated by the CPM is squelched. |
Recovery | Replace the CPM with one that is capable of generating the 2048kHz BITS output signal, or set tSyncIfTimingAdmBITSIfType to a value other than 'g703-2048khz (5)'. |
tmnxSyncIfTimBITS2048khzUnsupClr
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2135 |
Event name | tmnxSyncIfTimBITS2048khzUnsupClr |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.124 |
Default severity |
major |
Source stream | main |
Message format string | $tmnxHwIndex$ has been replaced with a CPM that meets the specification for 2048kHz or the BITS interface type is no longer 2048kHz. |
Cause | The tmnxSyncIfTimBITS2048khzUnsupClr notification is generated when a tmnxSyncIfTimBITS2048khzUnsup notification is outstanding and the CPM was replaced with one that meets the specifications for the 2048kHz BITS output signal under G.703 or tSyncIfTimingAdmBITSIfType is set to a value other than 'g703-2048khz (5)'. |
Effect | The CPM can now support the configuration of tSyncIfTimingAdmBITSIfType. |
Recovery | No recovery required. |
tmnxTunnelGrpEsaVmActivity
Property name | Value |
---|---|
Application name |
CHASSIS |
Event ID | 2208 |
Event name | tmnxTunnelGrpEsaVmActivity |
SNMP notification prefix and OID |
TIMETRA-CHASSIS-MIB.tmnxChassisNotification.219 |
Default severity |
minor |
Source stream | main |
Message format string | esa-$tmnxEsaId$/$tmnxEsaVmId$ is $tmnxTunnelGrpEsaVmActive$ in tunnel group $tmnxTunnelGrpEsaVmGroupAssoc$ |
Cause | The tmnxTunnelGrpEsaVmActivity notification is generated when a tunnel-capable ESA virtual machine that is associated with a tunnel group becomes active or inactive within its group. |
Effect | N/A |