OPEN_FLOW
tmnxOFFlowEntryInsertFailed
| Property name | Value | 
|---|---|
| Application name | OPEN_FLOW | 
| Event ID | 2001 | 
| Event name | tmnxOFFlowEntryInsertFailed | 
| SNMP notification prefix and OID | TIMETRA-OPEN-FLOW-MIB.tmnxOpenFlowNotification.1 | 
| Default severity | minor | 
| Source stream | main | 
| Message format string | Failed to add flow-entry for open-flow switch " $tmnxOFSwitchName$" flow-table $tmnxOFFlowTableId$. Flow-table Oper Status: $tmnxOFFlowTableOperStatus$. Failure Reason $tmnxOFNotifyDescription$ | 
| Cause | The tmnxOFFlowEntryInsertFailed notification is generated when a flow-entry could not be inserted into an open-flow table. | 
| Effect | The flow-entry won't be available in the flow-table. If inserting of a default flow-entry failed, then the value of tmnxOFFlowTableOperStatus is set to 'outOfService (3)'. | 
| Recovery | In order to insert the failed flow-entry into flow-table is to change the admin state of an open-flow switch instance to 'outOfService (3)' and then back to 'inService (1)' and try inserting the flow-entry again. |