Procedure 12-19: Upgrade OC-3 1+1 network to OC-12 1+1 network (single-rate circuit packs)

- Overview

Use this procedure to upgrade the OC-n bandwidth capacity of an in-service OC-3 1+1 network to an OC-12 1+1 network.

Important!

The optical 1+1 network must be equipped with Alcatel-Lucent 1665 DMXtend and/or Alcatel-Lucent 1665 DMX nodes only connected to the network using single-rate circuit packs. This upgrade procedure does not support upgrading optical 1+1 networks equipped with nodes other than Alcatel-Lucent 1665 DMXtend and/or Alcatel-Lucent 1665 DMX.

This procedure assumes that an Alcatel-Lucent 1665 DMXtend node is interconnected in an optical 1+1 network using the Main slots or a port pair in the Function/Growth slots with one of the following nodes:

  • Another Alcatel-Lucent 1665 DMXtend node using the Main slots or a port pair in the Function/Growth slots.

  • An Alcatel-Lucent 1665 DMX node using a port pair in the Function/Growth slots.

At nodes using the Main slots, the OC-3 OLIU circuit packs in the Main slots are replaced with OC-12 OLIU circuit packs. At nodes using a port pair in the Function/Growth slots, traffic is bridged/rolled to an OC-12 port pair in a different Function/Growth group.

This procedure assumes that the circuit pack in Main/Function/Growth slot 1 is always connected to the circuit pack in Main/Function/Growth slot 1 at the far-end node, and the circuit pack in Main/Function/Growth slot 2 is always connected to the circuit pack in Main/Function/Growth slot 2 at the far-end node. (Refer to the 1+1 network configuration examples at the end of the procedure.)

Ring Upgrade Mode

During the upgrade, each node connected to the optical 1+1 network using the Main slots must be provisioned in the Ring Upgrade Mode. The Ring Upgrade Mode allows cross-connections and provisioning data to be mapped to the replacement circuit pack and prohibits the following operations:

  • Software upgrades to the node (APPLY, INS-PRGM)

  • Cross-connection provisioning (ENT-CRS, DLT-CRS)

  • Manual equipment protection switching of the Function/Growth slots (SW-TOPROTN, SW-TOWKG)

The node remains in the Ring Upgrade Mode until it is manually provisioned back to the Normal mode. While in the Ring Upgrade Mode, the upgrade may be temporarily suspended or backed out. To prevent errors in the upgraded optical 1+1 network, keep all nodes in Ring Upgrade Mode until all nodes have been upgraded.

The Ring Upgrade Mode is an abnormal condition. Therefore, the ABN LED is lighted on the SYSCTL circuit pack faceplate and the WaveStar® CIT Alarm List shows the Ring Upgrade Mode as Not Alarmed.

Reported alarm severity levels

The alarm severity levels are reported using the Alarm List and the SYSCTL circuit pack faceplate LED indicators (CR, MJ, MN, or ABN).

Alarm List

The Alarm List is obtained by clicking the Alarm List button. The Alarm List reports detailed information about the current alarms on the local network element. This includes the assigned ASAP alarm severity levels.

For more information about provisioning and assigning ASAPs, refer to Chapter 6, System configuration procedures.

SYSCTL circuit pack faceplate LEDs

The SYSCTL circuit pack faceplate LEDs report the highest active alarm severity level at the local network element or within the alarm group based on the provisioned value of the Remote NE Status parameter.

If the Remote NE Status parameter is...

Then...

Enabled,

the SYSCTL circuit pack faceplate LEDs at the local network element display the highest active alarm severity level (if any) within the Alarm Group and the FE LED is lighted.

Disabled,

the SYSCTL circuit pack faceplate LEDs at the local network element display the highest active alarm severity level (if any) at the local network element only.

Enable Far End,

the SYSCTL circuit pack faceplate FE LED is lighted to indicate an alarm within the alarm group. However, the SYSCTL circuit pack faceplate LEDs at the local network element display the highest active alarm severity level (if any) at the local network element only.

For more information about provisioning the Remote NE Status feature, refer to Procedure 7-9: Set NE defaults — alarm gateway, alarm group, remote NE status, FTP/FTTD, security and history log thresholds.

- Privilege level

You must log in as a Privileged user to complete this procedure.

Required equipment

The following equipment is required to perform this procedure:

  • Optical power meter

  • Wrist strap

  • As optical spans are upgraded in the 1+1 network, ensure that technicians are available at each end of an optical span as it is upgraded.

  • At each Alcatel-Lucent 1665 DMXtend and Alcatel-Lucent 1665 DMX node connected to the 1+1 network using a port pair in the Function/Growth slots, an OC-12 port pair an OC-12 OLIU circuit pack pair in a different Function/Growth group

    If required, install the OC-12 OLIU circuit packs and/or pluggable transmission modules in the Function/Growth group and provision the OC-12 port and DCC termination parameters. Refer to Chapter 4, Install and provision circuit packs/OLIUs procedures.

    The replacement OC-12 port pair must have compatible optics. For example, do not replace a port pair that has long reach optics with a port pair that has intermediate reach optics. Refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Applications and Planning Guide, 365-372-324 for the SONET optical specifications.

  • At each Alcatel-Lucent 1665 DMXtend node connected to the 1+1 network using LNW40 OC-3 OLIU circuit packs in the Main slots, 2 replacement LNW38 OC-12 OLIU circuit packs.

    The replacement circuit packs must have compatible optics. For example, do not replace a circuit pack that has long reach optics with a circuit pack that has intermediate reach optics. Refer to Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Applications and Planning Guide, 365-372-324 for the SONET optical specifications.

Important!

Release 9.0 or later software is required to support the OC-3 1+1 network to OC-12 1+1 network upgrade.

Important!

All nodes in the existing network must have the same software release before upgrading the network.

NOTICE

Equipment damage

Rocking circuit packs back and forth when removing or installing them can damage circuit pack and/or shelf connectors.

Do not rock circuit packs back and forth when removing or installing them. Carefully slide circuit packs into or out of the shelf slot.

DANGER 

NOTICE

Service-disruption hazard

Removing or installing circuit packs during a System Reset can cause system errors.

Do not remove or install a circuit pack during a System Reset. If a System Reset occurs, wait until the System Reset is complete, then remove or install the circuit pack.

- Before you begin

Prior to performing this procedure:

  1. Refer to Laser safety and Electrostatic discharge information in Chapter 1, Safety.

  2. Obtain the work instructions for this procedure.

  3. Review the applicable office records for each fiber span in the 1+1 network and the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Applications and Planning Guide, 365-372-324 for detailed SONET optical specifications of the OC-12 OLIU circuit packs. Ensure that the OC-12 OLIU circuit packs are compatible with each fiber span in the 1+1 network. If required, refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) Applications and Planning Guide, 365-372-300.

  4. Review the applicable Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Software Release Description for any detailed procedures or cautions that may apply to this upgrade procedure. If required, refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) Customer Release Notes .

  5. If required, review the Alcatel-Lucent 1665 Data Multiplexer (DMX) User Operations Guide, 365-372-301 for procedures or cautions that may apply to this upgrade procedure.

  6. Determine the local operating procedures for removing a circuit pack. Local operating procedures for removing a circuit pack may vary. One method is to disconnect the optical fibers and remove the circuit pack. Another method is to verify the circuit pack active/standby status, perform manual switches if the circuit pack is active, and then disconnect the optical fibers and remove the circuit pack.

Steps

Important!

When optical fibers are disconnected during this procedure, inc. LOS alarms are reported. The holdover mode active condition may also be reported depending on the provisioned system timing mode.

Complete the following steps to upgrade an in-service OC-3 1+1 network to an OC-12 1+1 network.

 
1

From office records and work instructions, determine the current 1+1 network configuration. Note how the nodes are connected in the 1+1 network and make a drawing of the 1+1 network to reference during this upgrade procedure.

Reference:

Refer to the 1+1 network configuration examples at the end of the procedure.


2

Identify and log in to an Alcatel-Lucent 1665 DMXtend node in the 1+1 network to be upgraded.

Reference:

Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


3

Click the Alarm List button in the top right corner of the System View to view the NE Alarm List and verify that no alarms are present.

Refer to the appropriate trouble-clearing procedures to clear all existing alarms before continuing with this procedure.

Reference:

  • Alcatel-Lucent 1665 Data Multiplexer (DMX) Alarm Messages and Trouble Clearing Guide, 365-372-302

  • Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326


4

To verify that no loopbacks, protection switch lockouts, or protection switches are present, select View → Rolling Events. Under the line reading RTRV-COND-ALL determine if any loopbacks, protection switch lockouts, or protection switches are displayed.

Remove all existing loopbacks, protection switch lockouts, or protection switches before continuing with this procedure.

Reference:

  • Alcatel-Lucent 1665 Data Multiplexer (DMX) Alarm Messages and Trouble Clearing Guide, 365-372-302

  • Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326


5

Important!

Alcatel-Lucent 1665 DMXtend and Alcatel-Lucent 1665 DMX support test access.

If required, select Fault → Analysis → Test Access to access the Test Access Wizard and verify that no test access sessions exist.

If required, select Fault → Analysis → Test Access to access the Test Access Wizard and delete all existing test access sessions.

Reference:


6

Log in to the other node in the 1+1 network and repeat Step 3 through Step 5. Then continue with the next step.

Reference:

Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


7
DANGER 

NOTICE

Service-disruption hazard

If spanning tree is used for protection on the network being upgraded, this upgrade could cause Ethernet traffic loss when the spanning tree switches to a new topology.

Ensure that the spanning tree is configured correctly.

Important!

Alcatel-Lucent 1665 DMXtend and Alcatel-Lucent 1665 DMX support Ethernet service with spanning tree protection.

If Ethernet service is provisioned with spanning tree protection, verify that the existing spanning tree configuration is correct.

Reference:

Procedure 12-19.5: Verify spanning tree configuration


8

If upgrading a 1+1 network where the nodes are connected using the...

Then upgrade the 1+1 network using...

Main slots at both nodes,

Procedure 12-19.1: Upgrade OC-3 1+1 network (main-to-main). Then continue with Step 9.

Main slots at one node and the Function/Growth slots at the other node,

Procedure 12-19.2: Upgrade OC-3 1+1 network (main-to-function/growth). Then continue with Step 9.

Function/Growth slots at both nodes,

Procedure 12-19.3: Upgrade OC-3 1+1 network (function/growth-to-function/growth). Then continue with Step 9.

Reference:

Refer to the 1+1 network configuration examples at the end of the procedure.


9

Important!

At nodes connected to the 1+1 network using the Main slots, the system reports the ring upgrade mode standing condition (not alarmed) in the NE Alarm List until the node is manually provisioned back to the Normal mode.

At nodes connected to the 1+1 network using the Main slots, click the Alarm List button in the top right corner of the System View to view the NE Alarm List and verify that no alarms or standing conditions are present (except ring upgrade mode and ABN condition).

Refer to the appropriate trouble-clearing procedures to clear all existing alarms and standing conditions (except ring upgrade mode and ABN condition) before continuing with this procedure.

Reference:

  • Alcatel-Lucent 1665 Data Multiplexer (DMX) Alarm Messages and Trouble Clearing Guide, 365-372-302

  • Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326


10

At each node connected to the 1+1 network using a port pair in the Function/Growth slots, select Configuration → Update System → Update All.

Result:

A dialog box appears asking you to confirm executing this command. Click Yes.

The inc. OC3 LOS alarms for the original OC-3 ports clear.


11

At each node connected to the 1+1 network using a port pair in the Function/Growth slots, select Configuration → Cross-Connections and use the Cross-Connection Wizard to delete the remaining add cross-connections to the original OC-3 ports.


12

Important!

The 1+1 network must be alarm free with normal transmission before manually provisioning the nodes back to the Normal mode. After a node is manually provisioned back to the Normal mode, the node can not be returned to the pre-upgrade state using the backout procedure.

At each node connected to the 1+1 network using the Main slots, select Configuration → Normal Mode.

Result:

A dialog box appears asking you to confirm changing the NE Mode to Normal mode. Click Yes.

The ABN LED is turned off on the SYSCTL circuit pack faceplate and the Ring Upgrade Mode will be removed from the WaveStar® CIT alarm list.


13

Important!

It is recommended that the network element database be backed up to a remote OS (for example, OMS) after an upgrade. This creates a current backup copy that includes the replacement circuit packs. The remote OS could use this backup copy to restore the network element database in the event of a catastrophic failure. Attempts to restore the network element database using a backup copy created prior to the upgrade may result in circuit pack failures.

At each node in the 1+1 network, back up the network element database using the Configuration → Software → Remote Backup command.

Reference:


End of steps

1+1 network configuration examples

Nodes connected to the 1+1 network using the Main Slots

Figure 12-2: Nodes connected using Main slots
Nodes connected using Main slots
Figure 12-3: Nodes connected using Main slots and Function/Growth slots
Nodes connected using Main slots and Function/Growth slots
Figure 12-4: Nodes connected using Function/Growth slots
Nodes connected using Function/Growth slots
November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.