Workflow to manage port objects

Purpose

The following workflow describes the sequence of high-level tasks required to manage and configure port objects. This workflow assumes that the physical devices have been installed, commissioned, and discovered. See Chapter 8, Device commissioning and management for more information about device commissioning. See Chapter 9, Device discovery for more information about device discovery.

Note: After they are configured, port objects can be accessed using the equipment navigation tree. See Chapter 3, NFM-P navigation tree for more information about using the equipment navigation tree. for more information.

Stages
 

As required, configure Ethernet ports; see To configure Ethernet ports .


As required, change the port mode; see To change the port mode .


As required, migrate SAPs from access mode to hybrid mode; see To migrate SAPs from access mode to hybrid mode .


As required, configure the NFM-P to retain non-default port MTU values; see To configure the NFM-P to retain non-default port MTU values .


As required, copy or move L2 access interface SAPs between ports; see To copy or move L2 SAPs between ports .


As required, move L3 access interface SAPs within or between ports on the same NE; see To move L3 SAPs within or between ports or LAGs on the same NE .


As required, move L3 subscriber interface SAPs between ports on the same NE; see To move L3 subscriber interface SAPs between ports on the same NE .


As required, configure the bandwidth CAC function on a port or LAG; see To configure bandwidth CAC on an access SAP for services or a LAG .


As required, add a queue group to an Ethernet port; see To add a queue group to an Ethernet port .


10 

As required, configure SONET ports; see To configure SONET ports .


11 

As required, configure an HSMDA port scheduler override; see To configure an HSMDA override .


12 

As required, configure TDM DS3 ports; see To configure TDM DS3 ports .


13 

As required, configure serial ports; see To configure serial ports .


14 

As required, configure PW ports; see To configure PW ports .


15 

As required, configure ports on 7210 SAS devices, as follows:

  1. Configure a 7210 SAS-M channelized TDM DS1 or E1 port; see To configure a 7210 SAS-M channelized TDM DS1 or E1 port .

  2. Assign policies to a 7210 SAS Ethernet port; see To assign QoS policies to a 7210 SAS Ethernet port .

  3. Configure an SHG for 7210 SAS NEs; see To create a 7210 SAS SHG .

  4. Configure PoE ports on supporting 7210 SAS NEs; see To configure PoE ports on a 7210 SAS .


16 

As required, configure ports on 7705 SAR devices, as follows:

  1. virtual Ethernet ports on a 7705 SAR 2-port ring MDA; see To configure a virtual Ethernet port on a 7705 SAR 2-port ring MDA .

  2. PoE ports on a 7705 SAR; see To configure PoE ports on a 7705 SAR .

  3. GPS on a 7705 SAR; see To configure GPS on a 7705 SAR .

  4. 7705 SAR ASAP channelized TDM port; see To configure a 7705 SAR ASAP channelized TDM port .


17 

As required, configure the following on OmniSwitch devices:

  1. OmniSwitch Ethernet ports; see To configure OmniSwitch Ethernet ports .

  2. OmniSwitch PoE ports; see To configure OmniSwitch PoE Ports .