ISIS

tmnxIsisAdjacencyChange

Table 1. tmnxIsisAdjacencyChange properties

Property name

Value

Application name

ISIS

Event ID

2045

Event name

tmnxIsisAdjacencyChange

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.17

Default severity

warning

Source stream

main

Message format string

Adjacency status changed to $isisISAdjState$ for interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $vRtrIsisTrapLSPIDString$

Cause

The tmnxIsisAdjacencyChange notification is sent when an adjacency changes state, entering or leaving state up. The first 6 bytes of the tmnxIsisNotifTrapLSPID are the SystemID of the adjacent IS. The isisISAdjState is the new state of the adjacency.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisAdjBfdSessionSetupFail

Table 2. tmnxIsisAdjBfdSessionSetupFail properties

Property name

Value

Application name

ISIS

Event ID

2062

Event name

tmnxIsisAdjBfdSessionSetupFail

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.34

Default severity

warning

Source stream

main

Message format string

BFD session setup failed with reason $tmnxIsisBfdSessSetupFailReason$ for interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $tmnxIsisNotifTrapLSPIDString$

Cause

The tmnxIsisAdjBfdSessionSetupFail notification is sent when BFD session setup fails. The first 6 bytes of the tmnxIsisNotifTrapLSPID are the SystemID of the adjacent IS.

Effect

The system can not setup the BFD session.

Recovery

Depending on the tmnxIsisBfdSessSetupFailReason, recovery can be possible. Check the BFD configuration to recover.

tmnxIsisAdjRestartStatusChange

Table 3. tmnxIsisAdjRestartStatusChange properties

Property name

Value

Application name

ISIS

Event ID

2047

Event name

tmnxIsisAdjRestartStatusChange

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.19

Default severity

warning

Source stream

main

Message format string

Adjacency graceful restart status changed to $tmnxIsisISAdjRestartStatus$ for interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$

Cause

The tmnxIsisAdjRestartStatusChange notification is sent when an adjacency's graceful restart status changes. The tmnxIsisISAdjRestartStatus is the new graceful restart state of the adjacency.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisAreaMismatch

Table 4. tmnxIsisAreaMismatch properties

Property name

Value

Application name

ISIS

Event ID

2040

Event name

tmnxIsisAreaMismatch

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.12

Default severity

warning

Source stream

main

Message format string

Area mismatch on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, fragment: $vRtrIsisPDUFragmentString$, LSP size: $tmnxIsisNotifLSPSize$

Cause

The tmnxIsisAreaMismatch notification is sent when we receive a Hello PDU from an IS which does not share any area address. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. This decision is up to the agent to make, and may be based on the circuit or on some MAC level information.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisAuthFail

Table 5. tmnxIsisAuthFail properties

Property name

Value

Application name

ISIS

Event ID

2038

Event name

tmnxIsisAuthFail

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.10

Default severity

warning

Source stream

main

Message format string

Authentication failure on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, fragment: $vRtrIsisPDUFragmentString$

Cause

The tmnxIsisAuthFail notification is sent when we receive a PDU with incorrect authentication information field. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisAutTypeFail

Table 6. tmnxIsisAutTypeFail properties

Property name

Value

Application name

ISIS

Event ID

2037

Event name

tmnxIsisAutTypeFail

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.9

Default severity

warning

Source stream

main

Message format string

Authentication type failure on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, fragment: $vRtrIsisPDUFragmentString$

Cause

The tmnxIsisAutTypeFail notification is sent when we receive a PDU with the wrong authentication type field. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisCircIdExhausted

Table 7. tmnxIsisCircIdExhausted properties

Property name

Value

Application name

ISIS

Event ID

2046

Event name

tmnxIsisCircIdExhausted

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.18

Default severity

warning

Source stream

main

Message format string

Circuit-id space exhausted for level $tmnxIsisNotifSystemLevel$ - interface: $vRtrIfIndex$

Cause

The tmnxIsisCircIdExhausted notification is sent when the specific ISIS level cannot be started on a LAN interface as a unique circid could not be assigned due to the exhaustion of the circid space. This could happen only on the broadcast interfaces.

Effect

In such a case the interface is marked operationally down.

Recovery

When an operationally up interface is deleted, the circid can be reused by any interface which is waiting to receive a unique circid.

tmnxIsisCircMtuTooLow

Table 8. tmnxIsisCircMtuTooLow properties

Property name

Value

Application name

ISIS

Event ID

2064

Event name

tmnxIsisCircMtuTooLow

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.36

Default severity

warning

Source stream

main

Message format string

MTU size too low for interface: $vRtrIfIndex$ (level $tmnxIsisNotifSystemLevel$): $tmnxIsisNotifCircMtuSize$ smaller than $tmnxIsisNotifCircMinReqMtuSize$ (min required MTU size to transmit LSP or SNP)

Cause

The tmnxIsisCircMtuTooLow notification is sent when we attempt to a) configure a circuit which cannot propagate an LSP or SNP with max size tmnxIsisLevelLSPBuffSize. b) configure tmnxIsisLevelLSPBuffSize which is bigger than tmnxIsisLevelMaxOperLSPBuffSize. c) configure tmnxIsisSysOrigL1LSPBuffSize or tmnxIsisSysOrigL2LSPBuffSize which is bigger than tmnxIsisLevelMaxOperLSPBuffSize.

Effect

No effect.

Recovery

Increase port-mtu or decrease lsp-mtu.

tmnxIsisCorruptedLSPDetected

Table 9. tmnxIsisCorruptedLSPDetected properties

Property name

Value

Application name

ISIS

Event ID

2031

Event name

tmnxIsisCorruptedLSPDetected

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.3

Default severity

warning

Source stream

main

Message format string

Corrupted LSP detected on interface: $vRtrIfIndex$, level: $tmnxIsisNotifSystemLevel$, with LSP-id: $vRtrIsisTrapLSPIDString$.

Cause

The tmnxIsisCorruptedLSPDetected notification is generated when we find that and LSP that was stored in memory has become corrupted. We forward an LSP ID. We may have independent knowledge of the ID, but in some implementations there is a chance that the ID itself will be corrupted.

Effect

LSP is dropped.

Recovery

No recovery is necessary.

tmnxIsisCorruptRemainingLifetime

Table 10. tmnxIsisCorruptRemainingLifetime properties

Property name

Value

Application name

ISIS

Event ID

2066

Event name

tmnxIsisCorruptRemainingLifetime

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.38

Default severity

warning

Source stream

main

Message format string

Possible corrupt Remaining Lifetime $tmnxIsisLSPLifetimeRemain$ received on LSP $tmnxIsisLSPIdString$, for level: $tmnxIsisLevel$

Cause

The tmnxIsisCorruptRemainingLifetime notification is sent when an LSP is received with a possible corrupt Remaining Lifetime field. The Remaining Lifetime of a received LSP is considered as possible corrupt based on following algorithm: - The LSP has passed all acceptance tests. - The LSP is newer than the copy in the local LSPDB or no copy present. - The Remaining Lifetime in the received LSP is less than Zero Age Lifetime. - The adjacency to the neighbor from which the LSP is received has been up for a minimum of Zero Age Lifetime.

Effect

It is possible that an LSP is purged prematurely.

Recovery

The ISIS system will try to recover by setting the Remaining Lifetime to the tmnxIsisMinRemainingLspLifetime value.

tmnxIsisDatabaseOverload

Table 11. tmnxIsisDatabaseOverload properties

Property name

Value

Application name

ISIS

Event ID

2029

Event name

tmnxIsisDatabaseOverload

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.1

Default severity

warning

Source stream

main

Message format string

Overload (event $tmnxIsisLevelOverloadStatus$, system level: $tmnxIsisNotifSystemLevel$) - Level1State: $isisSysL1State$, Level2State: $isisSysL2State$ $tmnxIsisNotifyDescription$

Cause

The tmnxIsisDatabaseOverload notification is generated when the system enters or leaves the Overload state.

Effect

Database is overloaded.

Recovery

No recovery is necessary unless tmnxIsisNotifyDescription indicates it.

tmnxIsisExportLimitReached

Table 12. tmnxIsisExportLimitReached properties

Property name

Value

Application name

ISIS

Event ID

2050

Event name

tmnxIsisExportLimitReached

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.22

Default severity

major

Source stream

main

Message format string

ISIS level $tmnxIsisNotifSystemLevel$ has reached the export-limit $tmnxIsisExportLimit$, additional routes will not be exported into this ISIS level

Cause

The tmnxIsisExportLimitReached notification is sent when the total number of exported routes for the level is equal to the configured limit for exported routes, tmnxIsisExportLimit.

Effect

Additional routes would not be exported into this ISIS level from the route table.

Recovery

Change ISIS export policy.

tmnxIsisExportLimitWarning

Table 13. tmnxIsisExportLimitWarning properties

Property name

Value

Application name

ISIS

Event ID

2051

Event name

tmnxIsisExportLimitWarning

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.23

Default severity

warning

Source stream

main

Message format string

ISIS level $tmnxIsisNotifSystemLevel$ has reached $tmnxIsisExportLimitLogPercent$ percent of the export limit $tmnxIsisExportLimit$

Cause

The tmnxIsisExportLimitWarning notification is sent when the total number of exported routes or the level is equal to the configured percent, tmnxIsisExportLimitLogPercent of the export limit, tmnxIsisExportLimit. Additional routes will continue to be exported into this ISIS level from the route table till the export limit is reached.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisFailureDisabled

Table 14. tmnxIsisFailureDisabled properties

Property name

Value

Application name

ISIS

Event ID

2056

Event name

tmnxIsisFailureDisabled

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.28

Default severity

minor

Source stream

main

Message format string

ISIS disabled. Reason : $tmnxIsisFailureReasonCode$

Cause

A tmnxIsisFailureDisabled notification is generated when ISIS is operationally brought down. Reason for the failure is indicated by tmnxIsisFailureReasonCode.

Effect

ISIS is now operationally down.

Recovery

ISIS will auto restart.

tmnxIsisFaOperParticipationDown

Table 15. tmnxIsisFaOperParticipationDown properties

Property name

Value

Application name

ISIS

Event ID

2068

Event name

tmnxIsisFaOperParticipationDown

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.40

Default severity

warning

Source stream

main

Message format string

The oper-participation of $tmnxIsisFlexAlgoId$ in level $tmnxIsisNotifSystemLevel$ is operationally down due to $tmnxIsisNotifyDescription$.

Cause

The tmnxIsisFaOperParticipationDown notification is sent when the Flexible Algorithm Participation is operationally down. This notification occurs each time when: a) there are no Flexible Algorithm Definitions(FADs) present for the Flexible Algorithm. b) the FAD chosen for Flex-Algo calculation has unsupported parameters like unsupported: 1. Metric-Type 2. Calculation-Type 3. Constraint 4. Fad-Flags 5. Sub-Tlv

Effect

The node will cease to participate in that Flexible Algorithm, and won't advertise its participation in SR-algo sub-TLV.

Recovery

The operator may make sure if at least one FAD is present for that Flexible Algorithm, and in case of unsupported FAD, correct the FAD parameters to send supported values from remote side.

tmnxIsisIDLenMismatch

Table 16. tmnxIsisIDLenMismatch properties

Property name

Value

Application name

ISIS

Event ID

2033

Event name

tmnxIsisIDLenMismatch

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.5

Default severity

warning

Source stream

main

Message format string

ISIS-id length mismatch - field length: $tmnxIsisNotifFieldLen$, interface: $vRtrIfIndex$, on fragment: $vRtrIsisPDUFragmentString$

Cause

The tmnxIsisIDLenMismatch notification is sent when we receive a PDU with a different value of the System ID Length. This notification includes the index to identify the circuit where we saw the PDU and the header of the PDU which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. This decision is up to the agent to make, and may be based on the circuit or on some MAC level information.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisLdpSyncExit

Table 17. tmnxIsisLdpSyncExit properties

Property name

Value

Application name

ISIS

Event ID

2049

Event name

tmnxIsisLdpSyncExit

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.21

Default severity

warning

Source stream

main

Message format string

IGP-LDP synchronization has stopped for interface $vRtrIfIndex$ because Exit State $tmnxIsisIfLdpSyncTimerState$

Cause

The tmnxIsisLdpSyncExit notification is sent when IGP-LDP synchronization has stopped. The cause of this event is indicated by tmnxIsisIfLdpSyncTimerState, one of them being expiry of vRtrIfLdpSyncTimer.

Effect

The IGP link metric is restored to normal levels.

Recovery

No recovery is necessary.

tmnxIsisLdpSyncTimerStarted

Table 18. tmnxIsisLdpSyncTimerStarted properties

Property name

Value

Application name

ISIS

Event ID

2048

Event name

tmnxIsisLdpSyncTimerStarted

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.20

Default severity

warning

Source stream

main

Message format string

IGP-LDP synchronization timer has started for interface $vRtrIfIndex$.

Cause

The tmnxIsisLdpSyncTimerStarted notification is sent when the vRtrIfLdpSyncTimer is started. The timer is started from the time the LDP session to the neighbor is up over the interface.

Effect

This allows for the label FEC bindings to be exchanged.

Recovery

No recovery is necessary.

tmnxIsisLSPPurge

Table 19. tmnxIsisLSPPurge properties

Property name

Value

Application name

ISIS

Event ID

2060

Event name

tmnxIsisLSPPurge

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.32

Default severity

warning

Source stream

main

Message format string

Possible messages:

  • LSP Purge - interface: $vRtrIfIndex$, on level: $tmnxIsisNotifSystemLevel$, LSP: $vRtrIsisTrapLSPIDString$, POI SysId: $tmnxIsisNotifPurgeOriginatorString$ - $tmnxIsisNotifAdditionalInfo$

  • LSP Purge - interface: $vRtrIfIndex$, on level: $tmnxIsisNotifSystemLevel$, LSP: $vRtrIsisTrapLSPIDString$, POI sysId: $tmnxIsisNotifPurgeOriginatorString$, rcvd sysId: $tmnxIsisNotifPurgeSourceString$ - $tmnxIsisNotifAdditionalInfo$

Cause

The tmnxIsisLSPPurge notification is sent when a LSP is purged. This notification includes the system ID of the originator, or the upstream source of the purge, which may help a network manager to locate the origin of the purge and thus the cause of the purge.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisLSPTooLargeToPropagate

Table 20. tmnxIsisLSPTooLargeToPropagate properties

Property name

Value

Application name

ISIS

Event ID

2042

Event name

tmnxIsisLSPTooLargeToPropagate

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.14

Default severity

warning

Source stream

main

Message format string

LSP too large to propagate - LSP size: $tmnxIsisNotifLSPSize$, on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $vRtrIsisTrapLSPIDString$

Cause

The tmnxIsisLSPTooLargeToPropagate notification is sent when we attempt to propagate an LSP which is larger than the dataLinkBlockSize for a circuit. This should be an edge-triggered notification. We should not send a second notification about PDUs received from the same source.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisManualAddressDrops

Table 21. tmnxIsisManualAddressDrops properties

Property name

Value

Application name

ISIS

Event ID

2030

Event name

tmnxIsisManualAddressDrops

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.2

Default severity

warning

Source stream

main

Message format string

Configured manual area address $isisManAreaAddrString$ being ignored when computing routes

Cause

This notification is generated when one of the manual area addresses assigned to this system is ignored when computing routes. The object isisManAreaAddrExistState describes the area that has been dropped. This notification is edge triggered, and should not be regenerated until an address that was used in the previous computation has been dropped.

Effect

Assigned manual area address is ignored for computing routes.

Recovery

No recovery is necessary.

tmnxIsisMaxAreaAddrsMismatch

Table 22. tmnxIsisMaxAreaAddrsMismatch properties

Property name

Value

Application name

ISIS

Event ID

2034

Event name

tmnxIsisMaxAreaAddrsMismatch

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.6

Default severity

warning

Source stream

main

Message format string

Max area addresses mismatch - max area addresses: $tmnxIsisNotifMaxAreaAddress$, interface: $vRtrIfIndex$, on fragment: $vRtrIsisPDUFragmentString$

Cause

The tmnxIsisMaxAreaAddrsMismatch notification is sent when we receive a PDU with a different value of the Maximum Area Addresses. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisMaxSeqExceedAttempt

Table 23. tmnxIsisMaxSeqExceedAttempt properties

Property name

Value

Application name

ISIS

Event ID

2032

Event name

tmnxIsisMaxSeqExceedAttempt

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.4

Default severity

warning

Source stream

main

Message format string

Protocol disabled due to attempt to exceed the maximum sequence on level: $tmnxIsisNotifSystemLevel$, with LSP-id: $vRtrIsisTrapLSPIDString$. Shutdown for a while and start over.

Cause

The tmnxIsisMaxSeqExceedAttempt notification is generated when the sequence number on an LSP wraps the 32 bit sequence counter, we purge and wait to re-announce this information. Since these should not be generated rapidly, we generate an event each time this happens. A possible cause could be that the same system-id is configured on multiple nodes; when 2 nodes have the same system-id they both keep incrementing its LSP sequence number causing the sequence counter to rollover. While the first 6 bytes of the LSPID are ours, the other two contain useful information.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisOrigLSPBufSizeMismatch

Table 24. tmnxIsisOrigLSPBufSizeMismatch properties

Property name

Value

Application name

ISIS

Event ID

2043

Event name

tmnxIsisOrigLSPBufSizeMismatch

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.15

Default severity

warning

Source stream

main

Message format string

Originating LSP buffer size mismatch - LSP size: $tmnxIsisNotifOriginatingBuffSize$, on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $vRtrIsisTrapLSPIDString$

Cause

The tmnxIsisOrigLSPBufSizeMismatch notification is sent when a Level 1 LSP or Level 2 LSP is received which is larger than the local value for isisSysOrigL1LSPBuffSize or isisSysOrigL2LSPBuffSize respectively, or when a Level 1 LSP or Level2 LSP is received containing the originatingLSPBufferSize option and the value in the PDU option field does not match the local value for isisSysOrigL1LSPBuffSize or isisSysOrigL2LSPBuffSize respectively. We pass up the size from the option field or the size of the LSP that exceeds our configuration. This should be an edge-triggered notification. We should not send a second notification about PDUs received from the same source.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisOwnLSPPurge

Table 25. tmnxIsisOwnLSPPurge properties

Property name

Value

Application name

ISIS

Event ID

2035

Event name

tmnxIsisOwnLSPPurge

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.7

Default severity

warning

Source stream

main

Message format string

Own LSP Purge - interface: $vRtrIfIndex$, on level: $tmnxIsisNotifSystemLevel$, LSP: $vRtrIsisTrapLSPIDString$

Cause

The tmnxIsisOwnLSPPurge notification is sent when we receive a PDU with our SystemID and zero age. This notification includes the circuit Index if available, which may help a network manager identify the source of the confusion.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisPfxLimitOverloadWarning

Table 26. tmnxIsisPfxLimitOverloadWarning properties

Property name

Value

Application name

ISIS

Event ID

2061

Event name

tmnxIsisPfxLimitOverloadWarning

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.33

Default severity

warning

Source stream

main

Message format string

Overload warning $tmnxIsisNotifAdditionalInfo$

Cause

The tmnxIsisPfxLimitOverloadWarning notification is sent when the number of prefixes in the system reaches the tmnxIsisPrefixLimitThreshold or the tmnxIsisPrefixLimit.

Effect

When tmnxIsisPrefixLimit is not yet reached, but the tmnxIsisPrefixLimitThreshold is reached there is no direct effect; but when the number of prefixes grows the system might go into overload. When the tmnxIsisPrefixLimit is reached and the object tmnxIsisPrefixLimitLogOnly is false, IS-IS will be into overload. There is no direct effect when the object tmnxIsisPrefixLimitLogOnly is true.

Recovery

Increase the IS-IS prefix limit.

tmnxIsisProtoSuppMismatch

Table 27. tmnxIsisProtoSuppMismatch properties

Property name

Value

Application name

ISIS

Event ID

2044

Event name

tmnxIsisProtoSuppMismatch

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.16

Default severity

warning

Source stream

main

Message format string

Supported protocol mismatch - supported protocol: $tmnxIsisNotifProtocolsSupported$, on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $vRtrIsisTrapLSPIDString$

Cause

The tmnxIsisProtoSuppMismatch notification is sent when a non-pseudonode segment 0 LSP is received that has no matching protocols supported. This may be because the system does not generate the field, or because there are no common elements. The list of protocols supported should be included in the notification: it may be empty if the TLV is not supported, or if the TLV is empty. This should be an edge-triggered notification. We should not send a second notification about PDUs received from the same source.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisRejectedAdjacency

Table 28. tmnxIsisRejectedAdjacency properties

Property name

Value

Application name

ISIS

Event ID

2041

Event name

tmnxIsisRejectedAdjacency

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.13

Default severity

warning

Source stream

main

Message format string

Rejected adjacency on interface: $vRtrIfIndex$, for level:$tmnxIsisNotifSystemLevel$

Cause

The tmnxIsisRejectedAdjacency notification is sent when we receive a Hello PDU from an IS, but do not establish an adjacency due to a lack of resources. This should be an edge-triggered notification. We should not send a second notification about PDUs received from the same source.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisRejectedAdjacencySet

Table 29. tmnxIsisRejectedAdjacencySet properties

Property name

Value

Application name

ISIS

Event ID

2065

Event name

tmnxIsisRejectedAdjacencySet

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.37

Default severity

warning

Source stream

main

Message format string

Failed adj-set on interface: $tmnxIsisNotifyIfIndex$, for level:$tmnxIsisNotifSystemLevel$, description: $tmnxIsisNotifyDescription$

Cause

The tmnxIsisRejectedAdjacencySet notification is sent when an adjacency can not be assigned to an adjacency-set because it does not terminate on the same neighbor node as the other adjacencies. This notification each time the adjacency-set is programmed.

Effect

Adjacency-set nhops will not include this adjacency.

Recovery

Remove the interface from the adjacency-set or change the adjacency-set type to non parallel.

tmnxIsisRejectedAdjacencySid

Table 30. tmnxIsisRejectedAdjacencySid properties

Property name

Value

Application name

ISIS

Event ID

2059

Event name

tmnxIsisRejectedAdjacencySid

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.31

Default severity

warning

Source stream

main

Message format string

Failed SID adjacency on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, description: $tmnxIsisNotifyDescription$

Cause

The tmnxIsisRejectedAdjacencySid notification is sent when we do not establish an adjacency SID or adjacency PGID due to a lack of resources. This should be an edge-triggered notification. We should not send a second notification about adjacency SID allocation failure for the same adjacency. We should not send a second notification about adjacency PGID allocation failure for the same adjacency.

Effect

No effect.

Recovery

Whenever an ADJ-SID is released, the released ADJ-SID can be reused by any other adjacency which is waiting to receive an ADJ-SID. Whenever a PGID is released, the released PGID can be reused by any other adjacency which is waiting to receive a PGID.

tmnxIsisRejectedEndXSid

Table 31. tmnxIsisRejectedEndXSid properties

Property name

Value

Application name

ISIS

Event ID

2069

Event name

tmnxIsisRejectedEndXSid

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.41

Default severity

warning

Source stream

main

Message format string

Failed end-x SID on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, description: $tmnxIsisNotifyDescription$

Cause

The tmnxIsisRejectedEndXSid notification is sent when we do not establish a SRv6 End-X SID due to a lack of resources. This should be an edge-triggered notification. We should not send a second notification about end-x SID allocation failure for the same adjacency.

Effect

No effect.

Recovery

Whenever an end-x SID is released, the released end-x SID can be reused by any other adjacency which is waiting to receive an end-x SID.

tmnxIsisRejectedPgId

Table 32. tmnxIsisRejectedPgId properties

Property name

Value

Application name

ISIS

Event ID

2070

Event name

tmnxIsisRejectedPgId

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.42

Default severity

warning

Source stream

main

Message format string

Failed PGID on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, description: $tmnxIsisNotifyDescription$

Cause

The tmnxIsisRejectedPgId notification is sent when we do not establish a SRv6 adjacency PGID due to a lack of resources. This should be an edge-triggered notification. We should not send a second notification about adjacency PGID allocation failure for the same adjacency.

Effect

No effect.

Recovery

Whenever a PGID is released, the released PGID can be reused by any other adjacency which is waiting to receive a PGID.

tmnxIsisRoutesExpLmtDropped

Table 33. tmnxIsisRoutesExpLmtDropped properties

Property name

Value

Application name

ISIS

Event ID

2052

Event name

tmnxIsisRoutesExpLmtDropped

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.24

Default severity

warning

Source stream

main

Message format string

The number of redistributed routes into ISIS level $tmnxIsisNotifSystemLevel$ has dropped below the export limit $tmnxIsisExportLimit$

Cause

The tmnxIsisRoutesExpLmtDropped notification is sent when the total number of exported routes from the route table to this ISIS level drops below the configured export limit, tmnxIsisExportLimit.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisSequenceNumberSkip

Table 34. tmnxIsisSequenceNumberSkip properties

Property name

Value

Application name

ISIS

Event ID

2036

Event name

tmnxIsisSequenceNumberSkip

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.8

Default severity

warning

Source stream

main

Message format string

Sequence number skipped for LSP: $vRtrIsisTrapLSPIDString$, on interface: $vRtrIfIndex$, for level:$tmnxIsisNotifSystemLevel$

Cause

The tmnxIsisSequenceNumberSkip notification is sent when we need to increase the sequence number by more than one. When we receive an LSP without System ID and different contents, we may need to reissue the LSP with a higher sequence number. If two Intermediate Systems are configured with the same System ID, this notification will fire.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisSidError

Table 35. tmnxIsisSidError properties

Property name

Value

Application name

ISIS

Event ID

2057

Event name

tmnxIsisSidError

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.29

Default severity

minor

Source stream

main

Message format string

$tmnxIsisNotifyDescription$ SID:$tmnxIsisPrefixSidValue$, level: $tmnxIsisPrefixSidLevel$, mtid:$tmnxIsisRouteMtId$, type:$tmnxIsisPrefixSidType$, flags:$tmnxIsisPrefixSidFlags$, algo: $tmnxIsisPrefixSidAlgorithm$

Cause

This notification is generated when ISIS receives an IOM or CPM failure (system exhausted ILM, NHLFE, duplicate SID) while resolving and programming a received prefix SID.

Effect

The Segment Routing tunnel corresponding to this SID will not be programmed.

Recovery

In case of system exhaustion, the IGP instance goes into overload. The operator must manually clear the IGP overload condition after freeing resources. IGP will attempt to program at the next SPF all tunnels which previously failed the programming operation

tmnxIsisSidNotInLabelRange

Table 36. tmnxIsisSidNotInLabelRange properties

Property name

Value

Application name

ISIS

Event ID

2058

Event name

tmnxIsisSidNotInLabelRange

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.30

Default severity

minor

Source stream

main

Message format string

SID not in range of router:$tmnxIsisNotifPfxSidSysIDString$, SID: $tmnxIsisPrefixSidValue$, startLabel:$tmnxIsisNotifPfxSidRangeStartLbl$, maxIdx:$tmnxIsisNotifPfxSidRangeMaxIdx$ level: $tmnxIsisPrefixSidLevel$, mtid:$tmnxIsisRouteMtId$, type:$tmnxIsisPrefixSidType$, flags:$tmnxIsisPrefixSidFlags$, algo: $tmnxIsisPrefixSidAlgorithm$

Cause

This notification is generated when ISIS receives a SID which is not within the label range of the nhop router.

Effect

The Segment Routing tunnel corresponding to this SID will not be programmed.

Recovery

Increase the label range or change the SID index to be within the current label range.

tmnxIsisSidStatsIndexAlloc

Table 37. tmnxIsisSidStatsIndexAlloc properties

Property name

Value

Application name

ISIS

Event ID

2067

Event name

tmnxIsisSidStatsIndexAlloc

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.39

Default severity

warning

Source stream

main

Message format string

Possible messages:

  • Statistics Index Allocation status changed to $tmnxIsisNotifStatsIndexStatus$ for adjacency-set $tmnxIsisSidStatsAdjSet$

  • Statistics Index Allocation status changed to $tmnxIsisNotifStatsIndexStatus$ for adjacency interface $tmnxIsisSidStatsIfIndex$

  • Statistics Index Allocation status changed to $tmnxIsisNotifStatsIndexStatus$ for node $tmnxIsisSidStatsPrefix$/$tmnxIsisSidStatsPrefixLength$

Cause

The tmnxIsisSidStatsIndexAlloc notification is sent when the system is not able to allocate a statistic index to at least one SID. This indication is sent once, i.e. if the system retries to allocate a stat index but fails no new notification is sent. Conversely, in case the system resolves the situation and allocates stat indices to all needed SIDs a notification is sent to indicate that stat allocation is in nominal state.

Effect

No effect.

Recovery

No recovery is necessary.

tmnxIsisSpbEctFidCfgChg

Table 38. tmnxIsisSpbEctFidCfgChg properties

Property name

Value

Application name

ISIS

Event ID

2055

Event name

tmnxIsisSpbEctFidCfgChg

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.27

Default severity

warning

Source stream

main

Message format string

SPB ect-algorithm changed to $vRtrSpbEctFidAlgorithm$ for FID range $tmnxIsisSpbEctFidStart$-$tmnxIsisSpbEctFidEnd$ under $vRtrIsisLevel$

Cause

A tmnxIsisSpbEctFidCfgChg notification is sent when a configuration change is made to vRtrSpbEctFidTable affecting forwarding database identifiers in the range from tmnxIsisSpbEctFidStart to tmnxIsisSpbEctFidEnd.

Effect

There are changes in the vRtrSpbEctFidTable which may be out-of-sync with management application.

Recovery

Management application may need to synchronize with changes in the vRtrSpbEctFidTable.

tmnxIsisSpbNbrMultAdjExists

Table 39. tmnxIsisSpbNbrMultAdjExists properties

Property name

Value

Application name

ISIS

Event ID

2053

Event name

tmnxIsisSpbNbrMultAdjExists

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.25

Default severity

warning

Source stream

main

Message format string

SPB multiple adjacency exists for neighbor $vRtrIsisNbrSysIdString$ at system level $tmnxIsisNotifSystemLevel$

Cause

A tmnxIsisSpbNbrMultAdjExists notification is sent when IS-IS SPB instance detects a neighbor to which it already has a direct adjacency on another interface.

Effect

During SPF IS-IS SPB instance will have incorrect neighbor information and hence path computations will be incorrect.

Recovery

Check number of links to neighbor to make sure there is only one link.

tmnxIsisSpbNbrMultAdjExistsClear

Table 40. tmnxIsisSpbNbrMultAdjExistsClear properties

Property name

Value

Application name

ISIS

Event ID

2054

Event name

tmnxIsisSpbNbrMultAdjExistsClear

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.26

Default severity

warning

Source stream

main

Message format string

SPB multiple adjacency cleared for neighbor $vRtrIsisNbrSysIdString$ at system level $tmnxIsisNotifSystemLevel$

Cause

A tmnxIsisSpbNbrMultAdjExistsClear notification is sent when an IS-IS SPB instance clears the condition raised by tmnxIsisSpbNbrMultAdjExists notification.

Effect

During SPF IS-IS SPB instance will have correct neighbor information and hence path computations will be correct.

Recovery

None required.

tmnxIsisSrgbBadLabelRange

Table 41. tmnxIsisSrgbBadLabelRange properties

Property name

Value

Application name

ISIS

Event ID

2063

Event name

tmnxIsisSrgbBadLabelRange

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.35

Default severity

warning

Source stream

main

Message format string

Bad SRGB label range for advertising router:$tmnxIsisNotifSrgbAdvRtrSysIDString$, startLabel: $tmnxIsisNotifSrgbRangeStartLbl$, maxIdx:$tmnxIsisNotifSrgbRangeMaxIdx$, level:$tmnxIsisNotifSrgbLevel$, mtid: $tmnxIsisNotifSrgbMtId$ $tmnxIsisNotifAdditionalInfo$

Cause

The tmnxIsisSrgbBadLabelRange notification is sent when ISIS receives a bad SRGB label range from a router (for example, overlapping with another label range).

Effect

The configured Segment Routing tunnels will be wrong.

Recovery

Change the label range to recover.

tmnxIsisSrv6LocError

Table 42. tmnxIsisSrv6LocError properties

Property name

Value

Application name

ISIS

Event ID

2071

Event name

tmnxIsisSrv6LocError

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.43

Default severity

warning

Source stream

main

Message format string

$tmnxIsisNotifyDescription$, level:$tmnxIsisNotifSystemLevel$, mtid: $tmnxIsisRouteMtId$, algo:$tmnxIsisSrv6SidAlgorithm$

Cause

This notification is generated when ISIS receives an IOM or CPM failure (system exhausted ILM, NHLFE, duplicate SID) while resolving and programming a received SRv6 locator.

Effect

The Segment Routing tunnel corresponding to this locator will not be programmed.

Recovery

In case of system exhaustion, the IGP instance goes into overload. The operator must manually clear the IGP overload condition after freeing resources. IGP will attempt to program at the next SPF all SRv6 tunnels which previously failed the programming operation

tmnxIsisVersionSkew

Table 43. tmnxIsisVersionSkew properties

Property name

Value

Application name

ISIS

Event ID

2039

Event name

tmnxIsisVersionSkew

SNMP notification prefix and OID

TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.11

Default severity

warning

Source stream

main

Message format string

Protocol version skew - $tmnxIsisNotifProtocolVersion$ on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, fragment: $vRtrIsisPDUFragmentString$

Cause

The tmnxIsisVersionSkew notification is sent when we receive a Hello PDU from an IS running a different version of the protocol. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. This decision is up to the agent to make, and may be based on the circuit or on some MAC level information.

Effect

No effect.

Recovery

No recovery is necessary.

vRtrIsisSpbNbrMultAdjExists

Table 44. vRtrIsisSpbNbrMultAdjExists properties

Property name

Value

Application name

ISIS

Event ID

2025

Event name

vRtrIsisSpbNbrMultAdjExists

SNMP notification prefix and OID

TIMETRA-ISIS-MIB.vRtrIsisNotifications.25

Default severity

warning

Source stream

main

Message format string

SPB multiple adjacency exists for neighbor $vRtrIsisNbrSysIdString$ on interface $vRtrIfIndex$ at system level $vRtrIsisSystemLevel$

Cause

A vRtrIsisSpbNbrMultAdjExists notification is sent when IS-IS SPB instance detects a neighbor to which it already has a direct adjacency on another interface.

Effect

During SPF IS-IS SPB instance will have incorrect neighbor information and hence path computations will be incorrect.

Recovery

Check number of links to neighbor to make sure there is only one link.

vRtrIsisSpbNbrMultAdjExistsClear

Table 45. vRtrIsisSpbNbrMultAdjExistsClear properties

Property name

Value

Application name

ISIS

Event ID

2026

Event name

vRtrIsisSpbNbrMultAdjExistsClear

SNMP notification prefix and OID

TIMETRA-ISIS-MIB.vRtrIsisNotifications.26

Default severity

warning

Source stream

main

Message format string

SPB multiple adjacency cleared for neighbor $vRtrIsisNbrSysIdString$ on interface $vRtrIfIndex$ at system level $vRtrIsisSystemLevel$

Cause

A vRtrIsisSpbNbrMultAdjExistsClear notification is sent when an IS-IS SPB instance clears the condition raised by vRtrIsisSpbNbrMultAdjExists notification.

Effect

During SPF IS-IS SPB instance will have correct neighbor information and hence path computations will be correct.

Recovery

None required.

vRtrSpbEctFidCfgChg

Table 46. vRtrSpbEctFidCfgChg properties

Property name

Value

Application name

ISIS

Event ID

2027

Event name

vRtrSpbEctFidCfgChg

SNMP notification prefix and OID

TIMETRA-ISIS-MIB.vRtrIsisNotifications.27

Default severity

warning

Source stream

main

Message format string

SPB ect-algorithm changed to $vRtrSpbEctFidAlgorithm$ for FID range $vRtrSpbEctFidStart$-$vRtrSpbEctFidEnd$ under $vRtrIsisLevel$

Cause

A vRtrSpbEctFidCfgChg notification is sent when a configuration change is made to vRtrSpbEctFidTable affecting forwarding database identifiers in the range from vRtrSpbEctFidStart to vRtrSpbEctFidEnd.

Effect

There are changes in the vRtrSpbEctFidTable which may be out-of-sync with management application.

Recovery

Management application may need to synchronize with changes in the vRtrSpbEctFidTable.