LOGGER

STARTED

Table 1. STARTED properties

Property name

Value

Application name

LOGGER

Event ID

2001

Event name

STARTED

SNMP notification prefix and OID

N/A

Default severity

minor

Source stream

main

Message format string

Event collector $taskName$ started

Cause

An event log collector process was started.

Effect

Application events will be collected, filtered, and distributed, as configured.

Recovery

No recovery; not applicable.

tmnxClear

Table 2. tmnxClear properties

Property name

Value

Application name

LOGGER

Event ID

2010

Event name

tmnxClear

SNMP notification prefix and OID

TIMETRA-CLEAR-MIB.tmnxClearNotifications.1

Default severity

indeterminate

Source stream

main

Message format string

Clear function $tmnxClearName$ has been run with parameters: $tmnxClearParams$. The completion result is: $tmnxClearResult$. Additional error text, if any, is: $tmnxClearErrorText$

Cause

The tmnxClear notification is generated to report the results of the clear function that was run as a result of setting tmnxClearAction to 'doAction'.

Effect

If successful, the managed object was cleared.

Recovery

If failed, check that the managed object exists or that the clear function parameters are correct.

tmnxLogAccountingDataLoss

Table 3. tmnxLogAccountingDataLoss properties

Property name

Value

Application name

LOGGER

Event ID

2014

Event name

tmnxLogAccountingDataLoss

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.10

Default severity

major

Source stream

main

Message format string

Accounting data loss occurred for $subject$.

Cause

An accounting file was still being written to when the next collection interval ended.

Effect

A tmnxLogAccountingDataLoss notification is generated when an accounting file is still being written to when the next collection interval ends. The collection of statistics for the past interval is immediately stopped and collection is started for the next interval. There are missing records in the file for this past interval.

Recovery

N/A

tmnxLogAdminLocFailed

Table 4. tmnxLogAdminLocFailed properties

Property name

Value

Application name

LOGGER

Event ID

2006

Event name

tmnxLogAdminLocFailed

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.2

Default severity

major

Source stream

main

Message format string

Possible messages:

  • Compact flash location is not available for $subject$.

    Backup location, if any, will be used.

  • Compact flash location cf$tmnxLogFileIdAdminLocation$ is not available for $subject$.

    Backup location, if any, will be used.

Cause

Generated when the specified admin cflash is not available. Indicates that an alternative backup location, if specified, will be used.

Effect

N/A

Recovery

N/A

tmnxLogBackupLocFailed

Table 5. tmnxLogBackupLocFailed properties

Property name

Value

Application name

LOGGER

Event ID

2007

Event name

tmnxLogBackupLocFailed

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.3

Default severity

major

Source stream

main

Message format string

Compact flash backup location cf$tmnxLogFileIdBackupLoc$ is not available for $subject$

.File destination creation failed

Cause

Generated when the specified backup cflash is not available.

Effect

No log or billing file was created on either the admin or backup cflash.

Recovery

N/A

tmnxLogEventOverrun

Table 6. tmnxLogEventOverrun properties

Property name

Value

Application name

LOGGER

Event ID

2017

Event name

tmnxLogEventOverrun

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.12

Default severity

major

Source stream

main

Message format string

$tmnxLogThrottledEvents$ $tmnxLogThrottledEventID$ events were dropped because of logger input queue overrun.

Cause

A tmnxLogEventOverrun notification is generated at the end of the overrun throttling interval when one or more events of the type specified by tmnxLogThrottledEventID were dropped because the logger input stream's input queue limit was exceeded. The overrun throttling interval begins when the input queue limit is first exceeded and ends when the number of events in the input queue has dropped below an internal low watermark. At that point a tmnxLogEventOverrun notification is generated for each event type that had one or more events dropped because of the input queue overrun. The number of dropped events is specified by tmnxLogThrottledEvents.

Effect

Logger events have been dropped and were not sent to any log destination. tmnxEventDropCount has been incremented for each event dropped because of input queue overrun.

Recovery

The specific event information of dropped events cannot be recovered. The frequency of input queue overruns can be lessened by configuring as few event logs as possible, especially those going to remote destinations such as file, syslog and snmp notification logs

tmnxLogEventThrottled

Table 7. tmnxLogEventThrottled properties

Property name

Value

Application name

LOGGER

Event ID

2012

Event name

tmnxLogEventThrottled

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.8

Default severity

major

Source stream

main

Message format string

$tmnxLogThrottledEvents$ $tmnxLogThrottledEventID$ events were dropped in the last event throttling interval.

Cause

A tmnxLogEventThrottled notification is generated at the end of the throttling interval when one or more events are dropped because the throttling limit was reached for that interval.

Effect

N/A

Recovery

N/A

tmnxLogFileDeleted

Table 8. tmnxLogFileDeleted properties

Property name

Value

Application name

LOGGER

Event ID

2009

Event name

tmnxLogFileDeleted

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.5

Default severity

minor

Source stream

main

Message format string

Log file $tmnxLogFileDeletedName$ on compact flash cf$tmnxLogFileDeletedLocation$ has been deleted

Cause

Generated when a closed event log or accounting policy file has been deleted as part of the space contention cleanup.

Effect

N/A

Recovery

N/A

tmnxLogFileRollover

Table 9. tmnxLogFileRollover properties

Property name

Value

Application name

LOGGER

Event ID

2008

Event name

tmnxLogFileRollover

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.4

Default severity

major

Source stream

main

Message format string

Log file $tmnxLogFileIdPathName$ on compact flash cf$tmnxLogFileIdOperLocation$ has been rolled over

Cause

Generated when an event log or accounting policy file's rollover time has expired.

Effect

The file located as indicated by the value of tmnxLogFileIdOperLocation is closed and a new file is created as specified by tmnxLogFileIdAdminLocation and tmnxLogFileIdBackupLoc.

Recovery

No recovery is necessary.

tmnxLogOnlyEventOverrun

Table 10. tmnxLogOnlyEventOverrun properties

Property name

Value

Application name

LOGGER

Event ID

2018

Event name

tmnxLogOnlyEventOverrun

SNMP notification prefix and OID

N/A

Default severity

major

Source stream

main

Message format string

$tmnxLogOnlyOverrunEvents$ $tmnxLogOnlyOverrunEventName$ log-only (L) events were dropped because the logger input queue was overrun.

Cause

A tmnxLogOnlyEventOverrun notification is generated at the end of the overrun throttling interval when one or more log-only events of the type specified by tmnxLogOnlyOverrunEventName were dropped because the logger input stream's input queue limit was exceeded. The overrun throttling interval begins when the input queue limit is first exceeded and ends when the number of events in the input queue has dropped below an internal low watermark. At that point a tmnxLogOnlyEventOverrun notification is generated for each log-only event type that had one or more events dropped because of the input queue overrun. The number of dropped events is specified by tmnxLogOnlyOverrunEvents.

Effect

Logger events have been dropped and were not sent to any log destination. tmnxEventDropCount has been incremented for each event dropped because of input queue overrun.

Recovery

The specific event information of dropped events cannot be recovered. The frequency of input queue overruns can be lessened by configuring as few event logs as possible, especially those going to remote destinations such as file, syslog and snmp notification logs

tmnxLogOnlyEventThrottled

Table 11. tmnxLogOnlyEventThrottled properties

Property name

Value

Application name

LOGGER

Event ID

2016

Event name

tmnxLogOnlyEventThrottled

SNMP notification prefix and OID

N/A

Default severity

major

Source stream

main

Message format string

$tmnxLogOnlyThrottledEvents$ $tmnxLogOnlyThrottledEventName$ log-only (L) events were dropped in the last event throttling interval.

Cause

One or more log-only events were dropped because the throttling limit was reached for that interval.

Effect

A tmnxLogOnlyEventThrottled event is generated at the end of the throttling interval when one or more log-only events are dropped because the throttling limit was reached for that interval.

Recovery

N/A

tmnxLogSpaceContention

Table 12. tmnxLogSpaceContention properties

Property name

Value

Application name

LOGGER

Event ID

2005

Event name

tmnxLogSpaceContention

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.1

Default severity

major

Source stream

main

Message format string

Space contention occurred on compact flash cf $cFlashId$ during I/O for $subject$.

Cause

Generated when space contention occurs on the compact flash where a log or billing file creation is being attempted. Space contention exists if: Insufficient space is available on the compact flash to create a file of the same size as the file being rolled over. The first file of this type is being created and less than 10% of the total compact flash space is available. A write operation on a log or billing file is denied due to lack of space.

Effect

N/A

Recovery

N/A

tmnxLogTraceError

Table 13. tmnxLogTraceError properties

Property name

Value

Application name

LOGGER

Event ID

2002

Event name

tmnxLogTraceError

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.7

Default severity

critical

Source stream

main

Message format string

$tmnxLogTraceErrorTitle$: $tmnxLogTraceErrorMessage$

Cause

The tmnxLogTraceError notification is generated when a critical level trace error has been detected by the software. There are multiple triggers for such a trace error.

Effect

Effect varies depending on the specific trigger.

Recovery

Contact Nokia Support.

tmnxStdEventsReplayed

Table 14. tmnxStdEventsReplayed properties

Property name

Value

Application name

LOGGER

Event ID

2015

Event name

tmnxStdEventsReplayed

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.11

Default severity

major

Source stream

main

Message format string

Events $tmnxStdReplayStartEvent$ to $tmnxStdReplayEndEvent$ from $subject$ have been resent to SNMP notification target address $tmnxStdDestAddr$. The first event with no route to the target address was $tmnxStdReplayStart$.

Cause

An SNMP trap target address was added to the route table following a period when a route to that address was not available.

Effect

A tmnxStdEventsReplayed notification is generated when an SNMP trap target address is added to the RTM (tmnxVRtrID) following a period when the address had been removed. The value of tmnxStdReplayStartEvent is the SNMP notification request ID of the first event that was replayed. The value of tmnxStdReplayEndEvent is the SNMP notification request ID of the last missed event that was replayed. The value of tmnxStdReplayStart is the request ID of the first event for which there was no route to the trap target address.

Recovery

N/A

tmnxSysLogTargetProblem

Table 15. tmnxSysLogTargetProblem properties

Property name

Value

Application name

LOGGER

Event ID

2013

Event name

tmnxSysLogTargetProblem

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.9

Default severity

major

Source stream

main

Message format string

Problem encountered when trying to reach the destination specified in syslog $tmnxSysLogTargetId$ : $tmnxSysLogTargetProblemDescr$.

Cause

An event could not be delivered to the destination specified for the syslog.

Effect

A tmnxSysLogTargetProblem notification is generated when a problem is encountered when trying to deliver data to the syslog destination identified by the tmnxSysLogTargetId.

Recovery

N/A

tmnxTestEvent

Table 16. tmnxTestEvent properties

Property name

Value

Application name

LOGGER

Event ID

2011

Event name

tmnxTestEvent

SNMP notification prefix and OID

TIMETRA-LOG-MIB.tmnxLogNotifications.6

Default severity

indeterminate

Source stream

main

Message format string

Test event has been generated with system object identifier $sysObjectID$

System description: $sysDescr$

Cause

The tmnxTestEvent notification is generated when the object tmnxEventTest is set to a value of 'doAction' or the tools>perform>log>test-event CLI command has been entered. This event can be used to test that remote log destinations such as syslog and snmp trap destinations are configured correctly.

Effect

A tmnxTestEvent is generated.

Recovery

If the test event is not received by the log destination, verify that syslog and snmp trap destinations are configured correctly and that the interface link between the system and the remote receiver is up.