Procedure 12-2: Back out OC-3 UPSR to OC-12 UPSR upgrade

- Overview
DANGER 

NOTICE

Service-disruption hazard

If a node has been taken out of the Ring Upgrade Mode, the node cannot be returned to the original pre-upgrade state without affecting service.

All nodes connected to the UPSR using single-rate circuit packs in the Main slots or multirate circuit packs in the Main/Function/Growth slots must be in the provisioned Ring Upgrade Mode.

Use this procedure to back out an OC-3 UPSR to OC-12 UPSR upgrade.

Backing out of an upgrade in progress returns all nodes in the ring to their pre-upgrade state.

To temporarily stop the upgrade refer to Procedure 12-3: Suspend OC-3 UPSR to OC-12 UPSR upgrade.

- Privilege level

You must log in as a Privileged user to complete this procedure.

Required equipment

The following equipment is required to perform this procedure:

  • Optical power meter

  • Wrist strap

  • Original OC-3 OLIU circuit packs/pluggable transmission modules/port pairs for each node to be backed out

  • As the upgrade is backed out around the UPSR, ensure that technicians are available at each end of an optical span as the upgrade is backed out.

NOTICE

Equipment damage

Rocking circuit packs back and forth when removing or installing them can damage circuit pack and/or shelf connectors.

Do not rock circuit packs back and forth when removing or installing them. Carefully slide circuit packs into or out of the shelf slot.

DANGER 

NOTICE

Service-disruption hazard

Removing or installing circuit packs during a System Reset can cause system errors.

Do not remove or install a circuit pack during a System Reset. If a System Reset occurs, wait until the System Reset is complete, then remove or install the circuit pack.

- Before you begin

Prior to performing this procedure:

  1. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

  2. Review the applicable Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Software Release Description for any detailed procedures or cautions that may apply to this backout procedure. If required, refer to the Alcatel-Lucent 1665 Data Multiplexer (DMX) Customer Release Notes andAlcatel-Lucent 1850 Transport Service Switch (TSS-5) Software Release Description.

  3. If required, review the Alcatel-Lucent 1665 Data Multiplexer (DMX) User Operations Guide, 365-372-301 and/or Alcatel-Lucent 1665 Data Multiplexer Explore (DMXplore) User Operations Guide, 365-372-332 for procedures or cautions that may apply to this backout procedure.

  4. Determine the local operating procedures for removing a circuit pack/pluggable transmission module. Local operating procedures for removing a circuit pack/pluggable transmission module may vary. One method is to disconnect the optical fibers and remove the circuit pack/pluggable transmission module. Another method is to verify the circuit pack/port active/standby status, perform manual switches if the circuit pack/port is active, and then disconnect the optical fibers and remove the circuit pack/pluggable transmission module.

Steps

Important!

This procedure starts at the last node upgraded.

When optical fibers are disconnected during this procedure, inc. LOS, section DCC channel failed, and neighbor SYSCTL CP unavailable alarms are reported. The holdover mode active condition may also be reported depending on the provisioned system timing mode.

Complete the following steps to back out of an OC-3 UPSR to OC-12 UPSR upgrade.

 
1

From office records and work instructions, determine the network configuration and current status of the upgrade.


2

Identify the last node that was upgraded.

If the last node upgraded is...

Then...

the Alcatel-Lucent 1665 DMXtend starting node, and the ring upgrade is complete (all nodes connected to the UPSR using single-rate circuit packs in the Main slots or multirate circuit packs in the Main/Function/Growth slots are in the Ring Upgrade Mode),

Log in to the Alcatel-Lucent 1665 DMXtend starting node (refer to the UPSR example at the end of the procedure) and continue with Step 3.

not the Alcatel-Lucent 1665 DMXtend starting node,

Log in to the last node upgraded (refer to the UPSR example at the end of the procedure) and proceed to Step 7.

Reference:

Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


3

If required, verify the active/standby status of the OC-12 OLIU circuit pack/port in Main slot M1 and perform manual switches to switch traffic away from an active circuit pack/port.

Reference:

Procedure 12-2.3: Verify active/standby status of circuit pack/port to be backed out


4

Important!

This step may be performed if the Main and Function A/B slots were originally equipped with LNW140 OC-3/DS1 circuit packs.

If required, verify the active/standby status of the DS1 circuit pack in Function slot A1/B1 and perform manual switches to switch traffic away from an active circuit pack.

Reference:

Procedure 12-2.4: Verify active/standby status of DS1 circuit pack to be backed out


5

Important!

Do not reconnect the optical fibers until instructed to do so. The optical fibers are reconnected after the OC-12 circuit pack/port is backed out at each end of the optical span.

If the circuit pack/port is active for timing and/or transmission, opening the latch or disconnecting fibers causes timing and/or transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch.

If Main slot M1 was originally equipped with an...

Then...

LNW140 OC-3/DS1 circuit pack,

Perform the following:

  1. Open the faceplate latch on the OC-12 OLIU circuit pack in Main slot M1. Disconnect the optical fibers from the OC-12 OLIU circuit pack in Main slot M1.

  2. Remove the OC-12 circuit pack from Main slot M1.

  3. Remove the DS1 circuit pack from Function slot A1/B1.

  4. Remove the center divider between the M1 and A1/B1 sections of the slot.

  5. Install the original LNW140 OC-3/DS1 circuit pack in Main slot M1 and Function slot A1/B1.

Result:

The original LNW140 OC-3/DS1 circuit pack in Main slot M1 and Function slot A1/B1 is tested and autoprovisioned.

The system reports an unexpected circuit pack type condition for Main slot M1 and Function slot A1/B1. The system also reports an inc. OC12 LOS alarm for Main slot M1. Alarms may also be reported at other nodes in the ring.

LNW40, LNW302, or LNW601 OC-3 circuit pack,

Perform the following:

  1. Open the faceplate latch on the OC-12 OLIU circuit pack in Main slot M1. Disconnect the optical fibers from the OC-12 OLIU circuit pack in Main slot M1.

  2. Replace the OC-12 OLIU circuit pack in Main slot M1 with the original OC-3 OLIU circuit pack.

Result:

The original OC-3 OLIU circuit pack in Main slot M1 is tested and autoprovisioned.

The system reports an unexpected circuit pack type condition and an inc. OC12 LOS alarm for Main slot M1. Alarms may also be reported at other nodes in the ring.

LNW84 multirate OC-3/OC-12/OC-48 OLIU circuit pack with a single-rate OC-12 pluggable transmission module,

Perform the following:

  1. Select Configuration → Equipment and expand the circuit pack in Main slot M1. Click on the required OC-12 port and Select to obtain the port parameters. Provision the port Signal Type parameter to OC-3 and click Apply.

    The system reports an unexpected or failed Pluggable Transmission Module alarm for Main slot M1. Alarms may also be reported at other nodes in the ring.

  2. Disconnect the optical fibers from the OC-12 pluggable transmission module in Main slot M1.

  3. Replace the OC-12 pluggable transmission module in Main slot M1 with the original OC-3 pluggable transmission module.

Result:

The original OC-3 pluggable transmission module in Main slot M1 is tested and autoprovisioned.

The unexpected or failed Pluggable Transmission Module alarm for Main slot M1 clears, and the system reports an inc. OC3 LOS alarm for Main slot M1. Alarms may also be reported at other nodes in the ring.

LNW84 multirate OC-3/OC-12/OC-48 OLIU circuit pack with a multirate OC-3/OC-12/OC-48 pluggable transmission module,

Select Configuration → Equipment and expand the circuit pack in Main slot M1. Click on the required OC-12 port and Select to obtain the port parameters. Provision the port Signal Type parameter to OC-3 and click Apply.

Result:

The system reports an inc. OC3 LOF alarm for Main slot M1. Alarms may also be reported at other nodes in the ring.

Reference:

This completes the first phase of the backout at the starting node. The backout at the starting node will be completed after backing out of all the other nodes in the ring.

The following figure shows the state of the starting node and the adjacent optical spans.

Important!

If the original OC-3 port in Main slot M1 at the starting node is equipped with a multirate pluggable transmission module, inc. LOF alarms are reported.

View the figure
6

Log in to the adjacent node connected to Main/Function/Growth slot 1. (Refer to the UPSR example at the end of the procedure.)

Reference:

Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


7

Determine how the node is connected to the UPSR and back out the upgrade at the node.

If...

Then back out the UPSR upgrade using...

Alcatel-Lucent 1665 DMXtend connected to the UPSR using single-rate circuit packs in the Main slots,

Procedure 12-2.1: Back out high-speed OC-3 UPSR to OC-12 UPSR upgrade at node with single-rate circuit packs. Then continue with Step 8.

Alcatel-Lucent 1665 DMXtend connected to the UPSR using single-rate circuit packs in the Function/Growth slots,

Procedure 12-2.2: Back out low-speed OC-3 UPSR to OC-12 UPSR upgrade at node with single-rate circuit packs. Then continue with Step 8.

Alcatel-Lucent 1665 DMXtend connected to the UPSR using multlirate circuit packs in the Main/Function/Growth slots,

Procedure 12-2.5: Back out OC-3 UPSR to OC-12 UPSR upgrade at node with multirate circuit packs. Then continue with Step 8.

Alcatel-Lucent 1665 DMX connected to the UPSR using single-rate circuit packs in the Function/Growth slots,

Procedure 12-4.1: Back out low-speed OC-3 UPSR to OC-12 UPSR upgrade at node with single-rate circuit packs in Alcatel-Lucent 1665 Data Multiplexer (DMX) User Operations Guide, 365-372-301. Then continue with Step 8.

Alcatel-Lucent 1665 DMX connected to the UPSR using multirate circuit packs in the Main/Function/Growth slots,

Procedure 12-4.2: Back out OC-3 UPSR to OC-12 UPSR upgrade at node with multirate circuit packs in Alcatel-Lucent 1665 Data Multiplexer (DMX) User Operations Guide, 365-372-301. Then continue with Step 8.

Alcatel-Lucent 1665 DMXplore,

Procedure 12-4.1: Back out UPSR upgrade at node in Alcatel-Lucent 1665 Data Multiplexer Explore (DMXplore) User Operations Guide, 365-372-332. Then continue with Step 8.


8

Except for the starting node, has the upgrade been backed out of all nodes in the UPSR?

If...

Then...

No,

Repeat Step 6 and Step 7, as required, at the next node. (Refer to the UPSR example at the end of the procedure.)

Yes,

Continue with Step 9.


9

Log in to the starting node. (Refer to the UPSR example at the end of the procedure.)

Reference:

Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


10

If Main slot M2 is equipped with a...

single-rate circuit pack,

Proceed to Step 14.

multirate circuit pack,

Continue with the next step.


11

If required, verify the active/standby status of the OC-12 port on the multirate circuit pack in Main slot M2 and perform manual switches to switch traffic away from an active circuit pack/port.

Reference:

Procedure 12-2.3: Verify active/standby status of circuit pack/port to be backed out


12

Select Configuration → Equipment and expand the circuit pack in Main slot M2. Click on the required OC-12 port and Select to obtain the port parameters. Provision the port Signal Type parameter to OC-3 and click Apply.

Result:

If the multirate circuit pack in Main slot M2 is equipped with a...

Then...

single-rate OC-12 pluggable transmission module,

The system reports an unexpected or failed Pluggable Transmission Module alarm for Main slot M2.

The FAULT LED may light on the circuit packs in the Main slots, and the opposite end of the optical spans may report inc. OCN sig. degrade (BER) and section DCC channel failed alarms. Alarms may also be reported at other nodes in the ring.

multirate OC-3/OC-12/OC-48 pluggable transmission module and the opposite end of the original OC-3 span is equipped with a single-rate circuit pack/pluggable transmission module,

The system reports an inc. OC-3 LOS alarm for Main slot M2. Alarms may also be reported at other nodes in the ring.

multirate OC-3/OC-12/OC-48 pluggable transmission module and the opposite end of the original OC-3 span is equipped with a multirate pluggable transmission module,

The inc. LOF alarms clear. Transmission is now supported on the original OC-3 optical span.


13

Important!

If the port is active for timing and/or transmission, disconnecting the optical fibers causes timing and/or transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch.

If required, disconnect the optical fibers from the single-rate OC-12 pluggable transmission module in Main slot M2. Then replace the single-rate OC-12 pluggable transmission module in Main slot M2 with the original OC-3 pluggable transmission module.

Result:

The original OC-3 pluggable transmission module in Main slot M2 is tested and autoprovisioned.

The unexpected or failed Pluggable Transmission Module alarm for Main slot M2 clears, and the system reports an inc. OC3 LOS alarm for Main slot M2. Alarms may also be reported at other nodes in the ring.

Reference:

Procedure 4-16: Install pluggable transmission modules

STOP! To complete the upgrade, proceed to Step 18.


14

Important!

The UPD/INIT button does not work during this procedure.

At the System View select Configuration → Update System → Upgrade. Select main-1 (default) as the Directed Slot Choice and click OK.

Result:

A dialog box appears asking you to confirm executing this command. Click Yes.

If Main slot M1 is equipped with an...

Then...

LNW140 OC-3/DS1 circuit pack,

The unexpected circuit pack type condition for Main slot M1 and Function slot A1/B1 clears, and the system reports an unexpected circuit pack type condition for Main slot M2 and Function slot A2/B2.

LNW40, LNW302, or LNW601 OC-3 circuit pack,

The unexpected circuit pack type condition for Main slot M1 clears, and the system reports an unexpected circuit pack type condition for Main slot M2.


15

If required, verify the active/standby status of the OC-12 OLIU circuit pack in Main slot M2 and perform manual switches to switch traffic away from an active circuit pack.

Reference:

Procedure 12-2.3: Verify active/standby status of circuit pack/port to be backed out


16

Important!

This step may be performed if the Main and Function A/B slots were originally equipped with LNW140 OC-3/DS1 circuit packs.

If required, verify the active/standby status of the DS1 circuit pack in Function slot A2/B2 and perform manual switches to switch traffic away from an active circuit pack.

Reference:

Procedure 12-2.4: Verify active/standby status of DS1 circuit pack to be backed out


17

Important!

If the circuit pack is active for timing and/or transmission, opening the latch causes timing and/or transmission switches. Transmission hits (less than 60 ms) will occur for each separate protection switch.

Open the faceplate latch on the OC-12 OLIU circuit pack in Main slot M2. Disconnect the optical fibers from the OC-12 OLIU circuit pack in Main slot M2.

If Main slot M2 was originally equipped with an...

Then...

LNW140 OC-3/DS1 circuit pack,

Perform the following:

  1. Remove the OC-12 circuit pack from Main slot M2.

  2. Remove the DS1 circuit pack from Function slot A2/B2.

  3. Remove the center divider between the M2 and A2/B2 sections of the slot.

  4. Install the original LNW140 OC-3/DS1 circuit pack in Main slot M2 and Function slot A2/B2.

Result:

The original LNW140 OC-3/DS1 circuit pack in Main slot M2 and Function slot A2/B2 is tested and autoprovisioned.

The unexpected circuit pack type condition for Main slot M2 and Function slot A2/B2 clears, and the system reports an inc. OC3 LOS alarm for Main slot M2.

LNW40, LNW302, or LNW601 OC-3 circuit pack,

Replace the OC-12 OLIU circuit pack in Main slot M2 with the original OC-3 OLIU circuit pack.

Result:

The original OC-3 OLIU circuit pack in Main slot M2 is tested and autoprovisioned.

The unexpected circuit pack type condition for Main slot M2 clears, and the system reports an inc. OC3 LOS alarm for Main slot M2.

Reference:

Procedure 4-2: Install OLIU circuit packs in Main slots


18

If required at both ends of the optical span to be backed out, perform the following to connect the original OC-3 circuit pack/port in Main slot M2 and the required OC-3 circuit pack/port at the opposite end of the original OC-3 optical span:

  1. Clean and connect the transmit optical fibers.

  2. Measure the optical receive power of the receive fibers using an optical power meter. Select the appropriate LBO to attenuate the receive signal to the middle of the allowable optical receive power range. (Refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Applications and Planning Guide, 365-372-324 for the SONET optical specifications of the OC-3 circuit packs.)

  3. Clean and connect the receive fibers.

Result:

The inc. OC3 LOS alarms clear. Transmission is now supported on the original OC-3 optical span.

Reference:

Procedure 14-4: Perform connection and verification of optical facility


19

Important!

Perform this step only if the opposite end of the original optical span is an OC-3 port in a Function/Growth group and the Optical Synchronization Source is to be reprovisioned to the original OC-3 port.

If required at the opposite end of the original optical span, select Configuration → Timing/Sync to reprovision the Optical Synchronization Source to the original OC-3 port on the OC-3 OLIU circuit pack in slot 1 of the Function/Growth group.

Reference:

Procedure 6-5: Network Element synchronization provisioning


20

Important!

At nodes connected to the UPSR using single-rate circuit packs in the Main slots and multirate circuit packs in the Main/Function/Growth slots, the system reports the ring upgrade mode standing condition (not alarmed) in the NE Alarm List until the node is manually provisioned back to the Normal mode.

At nodes connected to the UPSR using single-rate circuit packs in the Main slots and multirate circuit packs in the Main/Function/Growth slots, click the Alarm List button in the top right corner of the System View to view the NE Alarm List and verify that no alarms or standing conditions are present (except ring upgrade mode and ABN condition).

Refer to the appropriate trouble-clearing procedures to clear all existing alarms and standing conditions (except ring upgrade mode and ABN condition) before continuing with this procedure.

Reference:

  • Alcatel-Lucent 1665 Data Multiplexer (DMX) Alarm Messages and Trouble Clearing Guide, 365-372-302

  • Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326

  • Alcatel-Lucent 1665 Data Multiplexer Explore (DMXplore) Alarms Messages and Trouble Clearing Guide, 365-372-333


21

Important!

This completes the backout procedure, except for taking the nodes connected to the UPSR using single-rate circuit packs in the Main slots and multirate circuit packs in the Main/Function/Growth slots out of the Ring Upgrade Mode. The decision to take these nodes out of the Ring Upgrade Mode or leave them depends on the reason the backout was necessary, and what is required before again starting the upgrade. In the Ring Upgrade Mode, UPSR cross-connections cannot be created or removed.

If required at each node connected to the UPSR using single-rate circuit packs in the Main slots and multirate circuit packs in the Main/Function/Growth slots, select Configuration → Normal Mode.

Result:

A dialog box appears asking you to confirm changing the NE Mode to Normal mode. Click Yes.

The ABN LED is turned off on the SYSCTL circuit pack faceplate and the Ring Upgrade Mode will be removed from the WaveStar® CIT alarm list.


End of steps

UPSR example
View the figure
November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.