Use this procedure to replace:
one unprotected out-of-service low-speed circuit pack in a Function/Growth group with a different type low-speed circuit pack.
two protected out-of-service low-speed circuit packs in a Function/Growth group with a different type low-speed circuit pack(s).
For in-service upgrades, refer to Chapter 12, Ring and circuit pack upgrade procedures.
NOTICE Equipment damage |
Rocking circuit packs back and forth when removing or installing them can damage circuit pack and/or shelf connectors.
Do not rock circuit packs back and forth when removing or installing them. Carefully slide circuit packs into or out of the shelf slot.
NOTICE Service-disruption hazard |
Removing or installing circuit packs during a System Reset can cause system errors.
Do not remove or install a circuit pack during a System Reset. If a System Reset occurs, wait until the System Reset is complete, then remove or install the circuit pack.
Prior to performing this procedure:
Refer to Required equipment and Before you begin in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Review the applicable Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Software Release Description for any detailed procedures or cautions that may apply to this procedure.
Complete the following steps to replace an out-of-service low-speed circuit pack with a different type low-speed circuit pack.
1 |
Log in to the node where the low-speed circuit pack(s) is to be replaced. Reference: Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session | ||
2 |
Removing a low-speed circuit pack with active traffic may result in a service interruption. Ensure that ALL service is removed from the affected low-speed circuit pack before continuing. From the System View, select View → Cross-Connections to obtain a current list of cross-connections and verify that no cross-connections exist on the low-speed circuit pack(s) to be removed. If required, select Configuration → Cross-Connections to access the Cross-Connection Wizard and delete any existing cross-connections. | ||
3 |
Open the faceplate latches on the affected low-speed circuit pack and remove the circuit pack from the shelf. Result: The system reports a CP removed alarm for the affected slot. If required, repeat this step for the companion circuit pack in the Function/Growth group. | ||
4 |
Select Configuration → Update System → Update All. Result: The CP removed alarm(s) clears for the affected slot(s). The affected slot(s) appears empty (circuit pack is not shown) in the WaveStar® CIT System View. | ||
5 |
Install the replacement low-speed circuit pack(s) in the affected slot(s). Reference: | ||
6 |
Important! It is recommended that the network element database be backed up to a remote OS (for example, the OMS) after the circuit pack is replaced. This creates a current backup copy that includes the replacement circuit pack. The remote OS could use this backup copy to restore the network element database in the event of a catastrophic failure. Attempts to restore the network element database using a backup copy created prior to replacing the circuit pack may result in circuit pack failures. Back up the network element database using Configuration → Software → Remote Backup. Reference: End of steps |