APS
apsEventChannelMismatch
Property name | Value |
---|---|
Application name | APS |
Event ID | 2003 |
Event name | apsEventChannelMismatch |
SNMP notification prefix and OID | APS-MIB.apsNotificationsPrefix.3 |
Default severity | minor |
Message format string | Channel Mismatch is declared |
Cause | Channel Mismatch notification is generated due to mismatch between the transmitted K1 channel (phys port) and the received K2 channel (phys port). |
Effect | N/A |
Recovery | Configure both local and remote with the same channel type. |
apsEventFEPLF
Property name | Value |
---|---|
Application name | APS |
Event ID | 2005 |
Event name | apsEventFEPLF |
SNMP notification prefix and OID | APS-MIB.apsNotificationsPrefix.5 |
Default severity | minor |
Message format string | FEPL failure is declared |
Cause | FEPLF (Far-End Protection Line Failure) notification is generated based on SF (Signal Failure) condition on the protection port in the received K1 Byte. |
Effect | Traffic will switch (Tx/Rx) to the working port if the traffic is presently Tx-ed/Rx-ed to/from the protection port. |
Recovery | N/A |
apsEventModeMismatch
Property name | Value |
---|---|
Application name | APS |
Event ID | 2002 |
Event name | apsEventModeMismatch |
SNMP notification prefix and OID | APS-MIB.apsNotificationsPrefix.2 |
Default severity | minor |
Message format string | Mode Mismatch is declared |
Cause | Mode Mismatch notification is generated due to a conflict between the current local mode (switching direction or architecture) and the received K2 mode information. |
Effect | For switching direction mismatch, the operational switching direction is changed to unidirectional. For switch architecture mismatch, the local end runs in 1+1 mode irrespective of the remote end switching architecture. |
Recovery | Configure both local and remote end to run in same switching mode (direction/architecture). |
apsEventPSBF
Property name | Value |
---|---|
Application name | APS |
Event ID | 2004 |
Event name | apsEventPSBF |
SNMP notification prefix and OID | APS-MIB.apsNotificationsPrefix.4 |
Default severity | minor |
Message format string | PSB Failure is declared |
Cause | A PSBF (Protection Switching Byte Failure) notification is generated due to inconsistent Rx K1 byte or invalid Rx K1 Byte. |
Effect | A PSBF condition is considered as signal failure (SF) on the protection port. |
Recovery | Correct the K1 byte value. |
apsEventSwitchover
Property name | Value |
---|---|
Application name | APS |
Event ID | 2001 |
Event name | apsEventSwitchover |
SNMP notification prefix and OID | APS-MIB.apsNotificationsPrefix.1 |
Default severity | minor |
Message format string | APS switchover from $subject$. |
Cause |
APS switchover between working port (channel 1) and protection port (channel 0) can happen due to change of status of any port or user-initiated switch commands on any port. |
Effect | Traffic is transmitted to and received from the other channel/port. |
Recovery | None. |
tApsChannelMismatchClear
Property name | Value |
---|---|
Application name | APS |
Event ID | 2007 |
Event name | tApsChannelMismatchClear |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.2 |
Default severity | minor |
Message format string | Channel Mismatch is cleared |
Cause | The channel mismatch clear notification is generated when the current status of an APS group gets the channel mismatch condition cleared. |
Effect | N/A |
Recovery | N/A |
tApsChanTxLaisStateChange
Property name | Value |
---|---|
Application name | APS |
Event ID | 2015 |
Event name | tApsChanTxLaisStateChange |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.10 |
Default severity | warning |
Message format string | APS forced Tx-LAIS state changed to $tApsChanTxLaisState$ |
Cause |
The tApsChanTxLaisStateChange notification is generated when there is a change in the value of tApsChanTxLaisState. |
Effect | N/A |
Recovery | Investigation is required to determine the cause of the change. |
tApsFEPLFClear
Property name | Value |
---|---|
Application name | APS |
Event ID | 2009 |
Event name | tApsFEPLFClear |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.4 |
Default severity | minor |
Message format string | FEPL Failure is cleared |
Cause | The FEPLF clear notification is generated when the current status of an APS group gets the FEPLF condition cleared. |
Effect | N/A |
Recovery | N/A |
tApsLocalSwitchCommandClear
Property name | Value |
---|---|
Application name | APS |
Event ID | 2011 |
Event name | tApsLocalSwitchCommandClear |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.6 |
Default severity | warning |
Message format string | Local - $apsCommandSwitch$ cleared |
Cause | The tApsLocalSwitchCommandClear notification is generated when an APS switch command in the local node gets cleared. Note that a switch command in the local node can be cleared either due to execution of the clear switch command in the local node or due to presence of a higher priority condition in the local or remote node. |
Effect | N/A |
Recovery | N/A |
tApsLocalSwitchCommandSet
Property name | Value |
---|---|
Application name | APS |
Event ID | 2010 |
Event name | tApsLocalSwitchCommandSet |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.5 |
Default severity | warning |
Message format string | Local - $apsCommandSwitch$ set |
Cause | The tApsLocalSwitchCommandSet is generated when any of the following APS switch commands is executed on an APS channel in the local node. The switch commands are lockoutOfProtection, forcedSwitchWorkToProtect, forcedSwitchProtectToWork, manualSwitchWorkToProtect, and manualSwitchProtectToWork. |
Effect | N/A |
Recovery | N/A |
tApsMcApsCtlLinkStateChange
Property name | Value |
---|---|
Application name | APS |
Event ID | 2014 |
Event name | tApsMcApsCtlLinkStateChange |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.9 |
Default severity | warning |
Message format string | Control link state changed to $tApsMcApsCtlLinkState$ |
Cause |
The tApsMcApsCtlLinkStateChange notification is generated when there is a change in the value of tApsMcApsCtlLinkState. |
Effect | N/A |
Recovery | Investigation is required to determine the cause of the change. |
tApsModeMismatchClear
Property name | Value |
---|---|
Application name | APS |
Event ID | 2006 |
Event name | tApsModeMismatchClear |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.1 |
Default severity | minor |
Message format string | Mode Mismatch is cleared |
Cause | The Mode mismatch clear notification is generated when the current status of an APS group gets the mode mismatch condition cleared. |
Effect | N/A |
Recovery | N/A |
tApsPrimaryChannelChange
Property name | Value |
---|---|
Application name | APS |
Event ID | 2016 |
Event name | tApsPrimaryChannelChange |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.11 |
Default severity | minor |
Message format string | Switch of the primary APS channel to $apsStatusK1K2Trans$. |
Cause |
The tApsPrimaryChannelChange notification is generated when there is a switch of the primary APS channel. Object apsStatusK1K2Trans indicates the new primary APS channel. |
Effect | N/A |
Recovery | Investigation is required to determine the cause of the change. |
tApsPSBFClear
Property name | Value |
---|---|
Application name | APS |
Event ID | 2008 |
Event name | tApsPSBFClear |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.3 |
Default severity | minor |
Message format string | PSB Failure is cleared |
Cause | The PSBF clear notification is generated when the current status of an APS group gets the PSBF condition cleared. |
Effect | N/A |
Recovery | N/A |
tApsRemoteSwitchCommandClear
Property name | Value |
---|---|
Application name | APS |
Event ID | 2013 |
Event name | tApsRemoteSwitchCommandClear |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.8 |
Default severity | warning |
Message format string | Remote - $apsCommandSwitch$ cleared |
Cause | The tApsRemoteSwitchCommandClear is generated when the received K1 byte (APS-MIB::apsStatusK1K2Rcv) from a peer indicates that an APS switch command just got cleared on an APS channel in the remote (peer) node. |
Effect | N/A |
Recovery | N/A |
tApsRemoteSwitchCommandSet
Property name | Value |
---|---|
Application name | APS |
Event ID | 2012 |
Event name | tApsRemoteSwitchCommandSet |
SNMP notification prefix and OID | TIMETRA-APS-MIB.tApsNotifications.7 |
Default severity | warning |
Message format string | Remote - $apsCommandSwitch$ set |
Cause | The tApsRemoteSwitchCommandSet is generated when the received K1 byte (APS-MIB::apsStatusK1K2Rcv) from a peer indicates that an APS switch command just got executed on an APS channel in the remote (peer) node. |
Effect | N/A |
Recovery | Investigation is required to determine the cause of the change. |