OPEN_FLOW
tmnxOFFlowEntryInsertFailed
Property name | Value |
---|---|
Application name | OPEN_FLOW |
Event ID | 2001 |
Event name | tmnxOFFlowEntryInsertFailed |
SNMP notification prefix and OID | TIMETRA-OPEN-FLOW-MIB.tmnxOpenFlowNotification.1 |
Default severity | minor |
Message format string | Failed to add flow-entry for open-flow switch " $tmnxOFSwitchName$" flow-table $tmnxOFFlowTableId$. Flow-table Oper Status: $tmnxOFFlowTableOperStatus$. Failure Reason $tmnxOFNotifyDescription$ |
Cause | The tmnxOFFlowEntryInsertFailed notification is generated when a flow-entry could not be inserted into an open-flow table. |
Effect | The flow-entry won't be available in the flow-table. If inserting of a default flow-entry failed, then the value of tmnxOFFlowTableOperStatus is set to 'outOfService (3)'. |