This section provides the reported alarm list with severity levels for Alcatel-Lucent 1850 TSS-5 shelves equipped with the VLNC2 System Controller, VLNC35 Fast Ethernet, and VLNC5x SONET/SDH Transport circuit packs.
Important!
If the Alcatel-Lucent 1850 TSS-5 shelf is equipped with a VLNC33 3-Port 100 Optical Fast Ethernet Port Expander, VLNC40/42/42B Ethernet Aggregator, VLNC60/61/62 Circuit Emulator, and/or VLNC64 Circuit Emulation Mini-Hub circuit pack, service-affecting incoming signal failures and equipment failures are reported using circuit pack faceplate LED indicators and Simple Network Management Protocol (SNMP) traps. Refer to Procedure 5-3: Address VLNC40/42/42B, VLNC60/61/62, or VLNC64 circuit pack related failures.
Important!
The severity level for certain alarms is provisionable. In the table below, a bold X identifies the default severity level for alarm messages that have provisionable severity levels. If there are multiple severity levels listed, yet there is no bold X, the severity level for that alarm or condition is determined by equipment provisioning.
Name |
Probable Cause |
Severity Level |
Go to | |||
---|---|---|---|---|---|---|
CR |
MJ |
MN |
SC 1 | |||
ABN condition |
MAN |
X 2 |
Locate the corresponding Not Alarmed (SC) in the alarm list and proceed to the appropriate procedure to clear the condition. | |||
ACO active |
INHAUDB |
X |
No action is necessary. | |||
AGNE communication failure |
PRCDRERR |
X |
||||
copy program IP |
EOC |
X |
No action is necessary. | |||
CP failed |
FACTERM |
X |
X |
|||
CP initialization IP |
FACTERM |
X |
No action is necessary. | |||
CP not allowed - crs |
FACTERM |
X |
X |
|||
CP not allowed - eqpt |
FACTERM |
X |
X |
|||
CP removed or CP failure |
FACTERM |
X |
X |
|||
CP software upgrade required |
FACTERM |
X 2 |
Procedure 5-13: Clear "CP software upgrade required" condition | |||
CPY-MEM backup IP |
EOC |
X |
No action is necessary. | |||
CPY-MEM download IP |
EOC |
X | ||||
CPY-MEM restore IP |
EOC |
X | ||||
DCC channel failed |
EOC |
X |
||||
dormant/exec code mismatch |
EOC |
X |
Procedure 5-16: Clear "dormant/exec code mismatch" condition | |||
DS1 loopback (to DSX) |
LPBKNETWORK |
X 2 |
||||
DS1 loopback (to DSX) requested inband from DSX |
LPBKNETWORK |
X 2 |
No action is necessary. | |||
DS1 loopback (to DSX) requested inband from Fiber |
LPBKNETWORK |
X 2 |
No action is necessary. | |||
DS1 loopback (to DSX) requested T3 FEAC from DSX |
LPBKNETWORK |
X 2 |
No action is necessary. | |||
DS1 loopback (to Fiber) |
LPBKNETWORK |
X 2 |
||||
DS1 loopback (to Fiber) requested inband from Fiber |
LPBKNETWORK |
X 2 |
No action is necessary. | |||
DS3 loopback (to DSX) |
LPBKNETWORK |
X 2 |
||||
DS3 loopback (to DSX) requested FEAC from DSX |
LPBKNETWORK |
X 2 |
No action is necessary. | |||
DS3 loopback (to Fiber) |
LPBKNETWORK |
X 2 |
||||
E1 loopback (to DSX) |
LPBKNETWORK |
X 2 |
||||
E1 loopback (to Fiber) |
LPBKNETWORK |
X 2 |
||||
E3 loopback (to DSX) |
LPBKNETWORK |
X 2 |
||||
E3 loopback (to Fiber) |
LPBKNETWORK |
X 2 |
||||
ENET terminal loopback |
LPBKNETWORK |
X 2 |
||||
environmentn |
MISC |
X |
X |
X |
X |
|
excessive holdover |
LHI |
X |
||||
fan shelf failed |
EXT |
X |
X |
X |
X |
Procedure 5-19: Clear "fan shelf failed" or "hardware failure" alarm |
FE-LAN CP failed |
FACTERM |
X |
X |
|||
forced switch |
WKSWPR-1 WKSWPR-2 |
X 2 |
||||
hardware failure |
HWFAIL |
X |
Procedure 5-19: Clear "fan shelf failed" or "hardware failure" alarm | |||
holdover mode active |
HLDOVRSYNC |
X |
||||
illegal CP type |
FACTERM |
X |
X |
|||
inc. DS3 Cbit Mismatch |
CBITMM |
X |
X |
X |
X |
|
inc. DS3 sig. out of frequency defect |
LPBKNETWORK |
X |
||||
inc. (from DSX) DS1 AIS |
AIS |
X |
X |
X |
Procedure 5-26: Clear "inc. (from DSX) DS1" conditions/alarms | |
inc. (from DSX) DS1 LOF |
LOF |
X |
X |
X | ||
inc. (from DSX) DS1 LOS |
LOS |
X |
X |
X | ||
inc. (from DSX) DS1 RAI |
RAI |
X |
||||
inc. (from DSX) DS1 sig. failed |
T-BERL |
X |
X |
X |
Procedure 5-26: Clear "inc. (from DSX) DS1" conditions/alarms | |
inc. (from DSX) DS3 AIS |
AIS |
X |
X |
X |
X |
|
inc. (from DSX) DS3 IDLE |
IDLE |
X |
X |
X |
X | |
inc. (from DSX) DS3 LOF |
LOF |
X |
X |
X |
X | |
inc. (from DSX) DS3 LOS |
LOS |
X |
X |
X |
X | |
inc. (from DSX) DS3 RAI |
RAI |
X |
||||
inc. (from DSX) DS3 sig. failed |
T-BERL |
X |
X |
X |
X |
|
inc. (from DSX) E1 AIS |
AIS |
X |
X |
X |
Procedure 5-27: Clear "inc. (from DSX) E1" conditions/alarms | |
inc. (from DSX) E1 LOF |
LOF |
X |
X |
X | ||
inc. (from DSX) E1 LOS |
LOS |
X |
X |
X | ||
inc. (from DSX) E1 RAI |
RAI |
X |
||||
inc. (from DSX) E1 sig. failed |
T-BERL |
X |
X |
X |
Procedure 5-27: Clear "inc. (from DSX) E1" conditions/alarms | |
inc. (from DSX) E3 AIS |
AIS |
X |
X |
X |
X |
Procedure 5-28: Clear "inc. (from DSX) E3" conditions/alarms |
inc. (from DSX) E3 LOS |
LOS |
X |
X |
X |
X | |
inc. (from DSX) E3 sig. failed |
EXC |
X |
X |
X |
X |
Procedure 5-28: Clear "inc. (from DSX) E3" conditions/alarms |
inc. (from fiber) DS3 AIS |
AIS |
X |
||||
inc. (from fiber) DS3 LOF |
LOF |
X | ||||
inc. (from fiber) DS3 RAI |
RAI-EGR |
X |
||||
inc. FE-LAN ANM |
ANM |
X |
X |
X |
X |
|
inc. FE-LAN LOS |
LOS |
X |
X |
X |
X |
|
inc. GE-LAN ANM |
ANM |
X |
X |
X |
X |
|
inc. GE-LAN LOS |
LOS |
X |
X |
X |
X |
|
inc. OCN line AIS |
AIS |
X |
X |
X |
X |
|
inc. OCN LOF |
LOF |
X |
X |
|||
inc. OCN LOS |
LOS |
X |
X |
|||
inc. OCN RFI-L |
FERF |
X |
X |
X |
Procedure 5-37: Clear "inc. OCN RFI-L/STMN MS-RFI" condition/alarm | |
inc. OCN sig. degrade (BER) |
T-BERL |
X |
X |
|||
inc. OCN sig. failed (BER) |
T-BERL |
X |
X |
|||
inc. STMN LOF |
LOF |
X |
X |
|||
inc. STMN LOS |
LOS |
X |
X |
|||
inc. STMN MS-AIS |
AIS |
X |
X |
X |
X | |
inc. STMN MS-RFI |
FERF |
X |
X |
X |
Procedure 5-37: Clear "inc. OCN RFI-L/STMN MS-RFI" condition/alarm | |
inc. STMN sig. degrade (BER) |
DEG |
X |
X |
|||
inc. STMN sig. failed (BER) |
EXC |
X |
X |
|||
inc. STSN AIS |
AIS |
X |
X |
X |
||
inc. STSN LOP |
LOP |
X |
X |
|||
inc. STSN RFI-P |
YEL |
X | ||||
inc. STSN sig. degrade (BER) |
T-BERP |
X |
X |
|||
inc. STSN sig. failed (BER) |
T-BERP |
X |
X |
|||
inc. STSN unequipped |
SLMF |
X |
X |
|||
inc. timing ref. off frequency |
SYNCOOS SYNC |
X |
X |
Procedure 5-39: Clear "inc. timing ref. off frequency" alarm | ||
inc. VCN AU-AIS |
AIS |
X |
X |
X |
||
inc. VCN AU-LOP |
LOP |
X |
X |
|||
inc. VCN HP-RFI |
YEL |
X | ||||
inc. VCN HP-UNEQ |
SLMF |
X |
X |
|||
inc. VCN LP-RFI |
YEL |
X | ||||
inc. VCN LP-UNEQ |
SLMF |
X |
X |
|||
inc. VCN sig. degrade (BER) |
DEG |
X |
X |
|||
inc. VCN sig. failed (BER) |
EXC |
X |
X |
|||
inc. VCN TU-AIS |
AIS |
X |
X |
X | ||
inc. VCN TU-LOP |
LOP |
X |
X |
|||
inc. VCG failed |
LOS |
X |
||||
inc. VCG LFD |
MISC |
X |
||||
inc. VCG LOA |
MISC |
X |
||||
inc. VT AIS |
AIS |
X |
X |
X |
||
inc. VT LOP |
LOP |
X |
X |
|||
inc. VT RFI-V |
YEL |
X | ||||
inc. VT sig. degrade (BER) |
T-BERP |
X |
X |
|||
inc. VT unequipped |
SLMF |
X |
X |
|||
incoming CRC-4 MFA mismatch |
CRCMM |
X |
Procedure 5-44: Clear "incoming CRC-4 MFA mismatch" condition | |||
inconsistent DCC values |
OSILINKERR |
X |
||||
install failed |
FACTERM |
X 2 |
||||
install program IP |
EOC |
X |
No action is necessary. | |||
lockout of protection |
INHSWPR |
X 2 |
||||
lockout switch |
WKSWPR-1 WKSWPR-2 |
X 2 | ||||
manual reference switch |
WKSWPR-1 WKSWPR-2 |
X 2 |
||||
manual switch |
WKSWPR-1 WKSWPR-2 |
X 2 |
||||
manual sync. mode switch |
HLDOVRSYNC |
X 2 |
||||
Member Signal Unacceptable - LCAS |
MSU-L |
X |
Procedure 5-53: Clear "Member Signal Unacceptable - LCAS" alarm | |||
NSAP count in L1 overflowed |
BUFROVLD |
X |
||||
NSAP count in L1 threshold crossed |
BUFROVLD |
X |
Procedure 5-55: Clear "NSAP count in L1 threshold crossed" alarm | |||
NTP server(s) unreachable |
EOC |
X |
||||
Pluggable Transmission Module removed |
FACTERM |
X |
X |
Procedure 5-57: Clear "Pluggable Transmission Module removed" alarm | ||
Port administratively disabled |
MAN |
X 2 |
Procedure 5-58: Clear "Port administratively disabled" condition | |||
power failure |
PWR |
X |
Procedure 5-59: Clear "power/fuse FA or FB failed" or "power failure" alarm | |||
power/fuse FA failed |
PWR |
X |
X |
X |
||
power/fuse FB failed |
PWR |
X |
X |
X |
||
Remote client signal failed |
GFP_RCF |
X |
X |
X |
X |
|
remote install/copy program IP |
EOC |
X |
No action is necessary. | |||
server signal fail (line) |
SSF-L |
X |
X |
|||
server signal fail (path, high-order) |
SSF-P |
X |
X |
Procedure 5-36: Clear "inc. OCN/STMN" conditions/alarms and/or Procedure 5-38: Clear "inc. STSN/VCN" conditions/alarms | ||
server signal fail (path, low-order) |
SSF-V |
X |
X |
|||
STSn cross-connect loopback |
LPBKNETWORK |
X |
||||
SYSCTL CP failed |
CONTR |
X |
||||
SYS dorm area corrupted |
EOC |
X |
||||
SYS generic corrupted. |
EOC |
X |
||||
time of day not provisioned |
CONTR |
X |
Procedure 5-63: Clear "time of day not provisioned" condition | |||
underlying resources unavailable, equipment |
URU-S |
X |
X |
|||
underlying resources unavailable, optical module |
URU-O |
X |
X |
Procedure 5-65: Clear "unexpected or failed Pluggable Transmission Module" alarm | ||
unexpected CP type |
FACTERM |
X |
X |
|||
unexpected or failed Pluggable Transmission Module |
FACTERM |
X |
X |
Procedure 5-65: Clear "unexpected or failed Pluggable Transmission Module" alarm | ||
unrecoverable hardware failure during download, replace CP |
FACTERM |
X |
Procedure 5-66: Clear "unrecoverable hardware failure during download, replace CP" alarm | |||
VCn cross-connect loopback |
LPBKNETWORK |
X |
||||
version mismatch |
FACTERM |
X |
||||
VT cross-connect loopback |
LPBKNETWORK |
X |
||||
waiting for download |
FACTERM |
X 2 |
No action is necessary. |
Copyright © 2011 Alcatel-Lucent. All rights reserved. |