This section provides the reported alarm list with severity levels.
Important!
The severity level for certain alarms is provisionable. In the table below, a bold X identifies the default severity level for alarm messages that have provisionable severity levels. If there are multiple severity levels listed, yet there is no bold X, the severity level for that alarm or condition is determined by equipment provisioning.
Name |
Probable Cause |
ASAP4 |
Severity Level |
Go to | |||
---|---|---|---|---|---|---|---|
CR |
MJ |
MN |
SC1 | ||||
−48V power/fuse FA failed |
PWR |
X |
X |
X |
X |
X |
Procedure 5-2: Clear "−48V power/fuse FA or FB failed" alarm |
−48V power/fuse FB failed |
PWR |
X |
X |
X |
X |
X | |
ABN condition |
MAN |
X2 |
Locate the corresponding Not Alarmed (SC) in the alarm list and proceed to the appropriate procedure to release/clear the condition. | ||||
ACO active |
INHAUDB |
X |
No action is necessary. | ||||
AGNE communication failure |
PRCDRERR |
X |
X |
X |
X |
X |
|
AUTO link shutdown |
ALS |
X |
X |
X |
X |
X2 |
|
automatic lock |
WKSWPR-1 WKSWPR-2 |
X2 |
|||||
Automatic protection switch mode mismatch |
APSMM |
X |
X |
X |
X |
X |
Procedure 5-7: Clear "Automatic protection switch mode mismatch" alarm |
Automatic protection switch primary section mismatch |
APSPSM |
X |
X |
X |
X |
X |
Procedure 5-8: Clear "Automatic protection switch primary section mismatch" alarm |
Automatic protection switch unused codes |
APSUC |
X |
X |
X |
X |
X |
Procedure 5-9: Clear "Automatic protection switch unused codes" alarm |
Automatic protection switch unresolved transient codes |
APSUT |
X |
X |
X |
X |
X |
Procedure 5-10: Clear "Automatic protection switch unresolved transient codes" alarm |
Circuit Provisioning Error |
PAPRVERR |
X |
X |
X |
X |
X |
|
copy program IP |
EOC |
X |
No action is necessary. | ||||
CP contributing to a pack failure |
CTNEQPT |
X |
X |
X |
X |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
CP initialization IP |
FACTERM |
X |
No action is necessary. | ||||
CP not allowed - crs |
FACTERM |
X |
X |
X |
X6 |
X |
|
CP not allowed - eqpt |
FACTERM |
X |
X |
X |
X6 |
X |
|
CP removed or CP failure |
FACTERM |
X |
X5 |
X |
X6 |
X |
|
CP software upgrade required |
FACTERM |
X |
Procedure 5-17: Clear "CP software upgrade required" condition | ||||
CPY-MEM backup IP |
EOC |
X |
No action is necessary. | ||||
CPY-MEM download IP |
EOC |
X | |||||
CPY-MEM restore IP |
EOC |
X | |||||
DATA CP failed |
FACTERM |
X |
X |
X |
X |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
DATA terminal loopback |
LPBKNETWORK |
X2 |
|||||
Default K-bytes |
BLSR-DKB |
X |
X |
X |
X |
X |
|
dormant/exec code mismatch |
EOC |
X |
Procedure 5-20: Clear "dormant/exec code mismatch" condition | ||||
DS1 CP failed |
FACTERM |
X |
X5 |
X |
X6 |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
DS1E1 CP failed |
FACTERM |
X |
X5 |
X |
X6 |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
DS1 loopback (to DSX) |
LPBKNETWORK |
X2 |
|||||
DS1 loopback (to Fiber) |
LPBKNETWORK |
X2 |
|||||
DS1 trmsn test IP |
LPBKNETWORK |
X2 |
No action is necessary. | ||||
DS3 loopback (to DSX) |
LPBKNETWORK |
X2 |
|||||
DS3 loopback (to Fiber) |
LPBKNETWORK |
X2 |
|||||
DS3 trmsn test IP |
LPBKNETWORK |
X2 |
No action is necessary. | ||||
DS3EC1 CP failed |
FACTERM |
X |
X5 |
X |
X6 |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
Duplicate Ring Node |
DUPL-RNG |
X |
X |
X |
X |
X |
|
E1 loopback (to DSX) |
LPBKNETWORK |
X2 |
|||||
E1 loopback (to Fiber) |
LPBKNETWORK |
X2 |
|||||
E1 trmsn test IP |
LPBKNETWORK |
X2 |
No action is necessary. | ||||
EC1 loopback (to DSX) |
LPBKNETWORK |
X2 |
|||||
EC1 loopback (to Fiber) |
LPBKNETWORK |
X2 |
|||||
ECV - excessive code violation |
ECV |
X |
X |
X |
X |
X |
Procedure 5-30: Clear "ECV - excessive code violation" alarm |
ENET facility loopback |
LPBKNETWORK |
X2 |
|||||
ENET terminal loopback |
LPBKNETWORK |
X2 | |||||
ENNI signaling communication failure with peer |
SIGPEER |
X |
X |
X |
X |
X |
Procedure 5-32: Clear "ENNI signaling communication failure with peer" alarm |
environmentn |
MISC |
X |
X |
X |
X |
||
Equipment configuration no longer supported |
DATAFLT |
X |
Procedure 5-44: Clear "Generic/Database/Equipment Configuration" alarms/conditions | ||||
ERP - Multiple RPL Owners |
ERP-MO |
X |
X |
X |
X |
X |
|
ERP - PDU Watchdog Timeout |
ERP-WD |
X |
X |
X |
X |
X |
|
Exceeded MTU size drop |
EMSD |
X |
X |
X |
X |
X |
|
excessive holdover |
LHI |
X |
X |
X |
X |
X |
|
Excessive Reserved Rate on RPR |
EXS-RSV |
X2 |
Procedure 5-37: Clear "Excessive Reserved Rate on RPR" condition | ||||
Extra Traffic Preempted |
RNG-PREEMPT |
X2 |
|||||
fan shelf failed |
EXT |
X |
X |
X |
X |
||
far end not LCAS |
NOTLCAS |
X |
|||||
Far-end protection line failure |
FEPRLF |
X |
X |
X |
X |
X |
Procedure 5-41: Clear "Far-end protection line failure" alarm |
FE-LAN CP failed |
FACTERM |
X |
X |
X |
X |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
forced switch |
WKSWPR-1 WKSWPR-2 |
X2 |
|||||
Forced Switch |
FSR |
X2 |
|||||
GE-LAN CP failed |
FACTERM |
X |
X |
X |
X |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
generic validation IP |
EOC |
X |
No action is necessary. | ||||
holdover mode active |
HLDOVRSYNC |
X |
|||||
illegal CP type |
FACTERM |
X5 |
X |
X |
X6 |
X |
|
Improper APS Codes |
APSPROV |
X |
X |
X |
X |
X |
|
inc. data type mismatch |
MISC |
X |
|||||
inc. DS1 sync. ref. AIS |
SYNC |
X |
X |
X |
X |
X |
|
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. DS1 sync. ref. BER |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. DS1 sync. ref. EOOF |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. DS1 sync. ref. LOF |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. DS1 sync. ref. LOS |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. DS1 sync. ref. OOL |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. DS3 Cbit Mismatch |
CBITMM |
X |
X |
X |
X |
X |
|
inc. E1 sync. ref. AIS |
SYNC |
X |
X |
X |
X |
X |
|
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. E1 sync. ref. BER |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. E1 sync. ref. CRC-4 MFA mismatch |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. E1 sync. ref. LOF |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. E1 sync. ref. LOS |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. E1 sync. ref. OOL |
SYNC |
X |
X |
X |
X |
X | |
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. (from DSX) DS1 AIS |
AIS |
X |
X |
X |
X |
X |
|
inc. (from DSX) DS1 LOF |
LOF |
X |
X |
X |
X |
X | |
inc. (from DSX) DS1 LOS |
LOS |
X |
X |
X |
X |
X | |
inc. (from DSX) DS1 RAI |
RAI |
X |
X |
X |
X |
X |
|
inc. (from DSX) DS1 sig. failed |
T-BERL |
X |
X |
X |
X |
X |
|
inc. (from DSX) DS3 AIS |
AIS |
X |
X |
X |
X |
X |
|
inc. (from DSX) DS3 IDLE |
IDLE |
X |
X |
X |
X |
X | |
inc. (from DSX) DS3 LOF |
LOF |
X |
X |
X |
X |
X | |
inc. (from DSX) DS3 LOS |
LOS |
X |
X |
X |
X |
X | |
inc. (from DSX) DS3 RAI |
RAI |
X |
X |
X |
X |
X |
|
inc. (from DSX) DS3 sig. failed |
T-BERL |
X |
X |
X |
X |
X |
|
inc. (from fiber) DS1 AIS |
AIS-EGR |
X |
X |
X |
X |
X |
|
inc. (from fiber) DS1 LOF |
LOF-EGR |
X |
X |
X |
X |
X | |
inc. (from fiber) DS1 RAI |
RAI-EGR |
X |
X |
X |
X |
X |
|
inc. (from fiber) DS3 AIS |
AIS-EGR |
X |
X |
X |
X |
X |
|
inc. (from fiber) DS3 LOF |
LOF-EGR |
X |
X |
X |
X |
X | |
inc. (from fiber) DS3 RAI |
RAI-EGR |
X |
X |
X |
X |
X |
|
inc. (from DSX) E1 AIS |
AIS |
X |
X |
X |
X |
X |
|
inc. (from DSX) E1 LOF |
LOF |
X |
X |
X |
X |
X | |
inc. (from DSX) E1 LOS |
LOS |
X |
X |
X |
X |
X | |
inc. (from DSX) E1 sig. failed |
T-BERL |
X |
X |
X |
X |
X | |
inc. EC1 line AIS |
AIS |
X |
X |
X |
X |
X |
|
inc. EC1 LOF |
LOF |
X |
X |
X |
X |
X | |
inc. EC1 LOS |
LOS |
X |
X |
X |
X |
X | |
inc. EC1 RFI-L |
FERF |
X |
X |
X |
X |
X | |
inc. EC1 section trace identifier mismatch |
TIM-S |
X |
X |
X5 |
X6 |
X |
Procedure 5-73: Clear "inc. section trace identifier mismatch" alarms |
inc. EC1 section trace identifier mismatch, diagnostic |
TIM-S-D |
X |
X |
X |
X |
X | |
inc. EC1 sig. degrade (BER) |
T-BERL |
X |
X |
X |
X |
X |
|
inc. EC1 sig. failed (BER) |
T-BERL |
X |
X |
X |
X |
X | |
inc. FE-LAN ANM |
ANM |
X |
X |
X |
X |
X |
|
inc. FE-LAN FEFI |
FERF |
X |
X |
X |
X |
X |
|
inc. FE-LAN LOS |
LOS |
X |
X |
X |
X |
X |
|
inc. GE-LAN ANM |
ANM |
X |
X5 |
X |
X6 |
X |
|
inc. GE-LAN LOS |
LOS |
X |
X5 |
X |
X6 |
X |
|
inc. LAG Partial Link Loss |
PLL |
X |
X |
X |
X |
X |
|
inc. LAG PLCF |
PLCF |
X |
X |
X |
X |
X | |
inc. LAG Total Link Loss |
TLL |
X |
X |
X |
X |
X | |
inc. line sync. ref. OOL |
SYNC |
X |
X |
X |
X |
X |
|
SYNCOOS |
X |
X |
X |
X |
X | ||
inc. LOS |
LOS |
X |
X5 |
X |
X6 |
X |
|
inc. Loss of Synch |
LSYNC |
X |
X5 |
X |
X6 |
X |
|
inc. MUX OCH LOS-P |
MUX-LOS-P |
X |
X |
X |
X |
X |
|
inc. OCN line AIS |
AIS |
X |
X5 |
X |
X |
X6 |
|
inc. OCN LOF |
LOF |
X |
X5 |
X |
X6 |
X | |
inc. OCN LOS |
LOS |
X |
X5 |
X |
X6 |
X | |
inc. OCN RFI-L |
FERF |
X |
X |
X |
X |
X |
|
inc. OCN section trace identifier mismatch |
TIM-S |
X |
X |
X5 |
X6 |
X |
Procedure 5-73: Clear "inc. section trace identifier mismatch" alarms |
inc. OCN section trace identifier mismatch, diagnostic |
TIM-S-D |
X |
X |
X |
X |
X | |
inc. OCN sig. degrade (BER) |
T-BERL |
X |
X5 |
X |
X6 |
X |
|
inc. OCN sig. failed (BER) |
T-BERL |
X |
X5 |
X |
X6 |
X | |
inc. ODU2 BDI |
BDI |
X |
X |
X |
X |
X6 |
|
inc. ODU2 DEG |
DEG |
X |
X5 |
X |
X6 |
X |
|
inc. ODU2 LCK |
LCK |
X |
X5 |
X |
X6 |
X |
|
inc. ODU2 OCI |
OCI |
X |
X5 |
X |
X6 |
X | |
inc. ODU2 SSF |
SSF |
X |
X5 |
X |
X6 |
X |
|
inc. OTS LOS-P |
LOS-P |
X |
X5 |
X |
X6 |
X |
|
inc. OTU2 BDI |
BDI |
X |
X |
X |
X |
X6 |
|
inc. OTU2 DEG |
DEG |
X |
X5 |
X |
X6 |
X |
|
inc. OTU2 LOF |
LOF |
X |
X5 |
X |
X6 |
X | |
inc. OTU2 LOM |
LOM |
X |
X5 |
X |
X6 |
X | |
inc. OTU2 LOS-P |
LOS-P |
X |
X5 |
X |
X6 |
X | |
inc. OTU2 SSF |
SSF |
X |
X5 |
X |
X6 |
X | |
inc. STS LOP |
LOP |
X |
X5 |
X |
X6 |
X |
|
inc. STSN3 AIS |
AIS |
X |
X5 |
X |
X6 |
X |
|
inc. STSN LOP |
LOP |
X |
X5 |
X |
X6 |
X | |
inc. STSN RFI-P |
YEL |
X |
X |
X |
X |
X | |
inc. STSN sig. degrade (BER) |
T-BERP |
X |
X5 |
X |
X6 |
X | |
inc. STSN sig. failed (BER) |
T-BERP |
X |
X5 |
X |
X6 |
X | |
inc. STSN unequipped |
SLMF |
X |
X5 |
X |
X6 |
X | |
inc. VCG failed |
LOS |
X |
X5 |
X |
X6 |
X |
|
inc. VCG LFD |
MISC |
X |
|||||
inc. VCG LOA |
MISC |
X |
|||||
inc. VC TU-AIS |
AIS |
X |
X |
X |
X |
X |
|
inc. VC TU-LOP |
LOP |
X |
X |
X |
X |
X | |
inc. VC LP-RFI |
YEL |
X |
X |
X |
X |
X | |
inc. VC unequipped |
SLMF |
X |
X |
X |
X |
X | |
inc. VT AIS |
AIS |
X |
X |
X5 |
X6 |
X |
|
inc. VT LOP |
LOP |
X |
X |
X5 |
X6 |
X | |
inc. VT RFI-V |
YEL |
X |
X |
X |
X |
X | |
inc. VT sig. degrade (BER) |
T-BERP |
X |
X |
X5 |
X6 |
X | |
inc. VT unequipped |
SLMF |
X |
X |
X5 |
X6 |
X | |
incoming CRC-4 MFA mismatch |
CRCMM |
X |
X |
X |
X |
X |
Procedure 5-80: Clear "incoming CRC-4 MFA mismatch" condition |
incompatible CP version |
FACTERM |
X |
X |
X |
X |
X |
|
Inconsistent APS Codes |
APSC |
X |
X |
X |
X |
X |
|
Inconsistent crs map |
CONTR |
X |
|||||
inconsistent DCC values |
OSILINKERR |
X |
X |
X |
X |
X |
|
Inconsistent Ring Prot Mode |
RNG-IRPM |
X |
X |
X |
X |
X |
|
Inconsistent VT BLSR Access |
RNG-IVTBA |
X2 |
Procedure 5-86: Clear "Inconsistent VT BLSR Access" condition | ||||
inhibit switch |
INHSWPR WKSWPR-1 WKSWPR-2 |
X |
X |
X |
X |
X2 |
|
install failed |
FACTERM |
X2 |
|||||
install program IP |
EOC SWFTDWN |
X |
No action is necessary. | ||||
Invalid Database |
DATAFLT |
X |
Procedure 5-44: Clear "Generic/Database/Equipment Configuration" alarms/conditions | ||||
Invalid Subshelf Configuration |
DATAFLT |
X |
|||||
Line Automatic Switch |
LAS |
X2 |
|||||
line DCC channel failed |
EOC-L |
X |
X |
X |
X |
X |
|
lockout of protection |
INHSWPR |
X2 |
|||||
Lockout Switch |
LPS |
X2 |
|||||
lockout switching |
GP |
X2 |
|||||
Maintenance Mode |
DATAFLT |
X2 |
Procedure 5-44: Clear "Generic/Database/Equipment Configuration" alarms/conditions | ||||
manual reference switch |
WKSWPR-1 WKSWPR-2 |
X2 |
|||||
manual switch |
WKSWPR-1 WKSWPR-2 MSR |
X2 |
|||||
Manual Switch |
MSR |
X2 |
|||||
manual sync. mode switch |
HLDOVRSYNC |
X2 |
|||||
Member Not Collecting/ Distributing |
MNCD |
X |
X |
X |
X |
X |
Procedure 5-98: Clear "Member Not Collecting/Distributing" alarm |
Member Signal Unacceptable - LCAS |
MSU-L |
X |
X |
X |
X5,6 |
X |
Procedure 5-99: Clear "Member Signal Unacceptable - LCAS" alarm |
Multiple Databases |
DATAFLT |
X |
Procedure 5-44: Clear "Generic/Database/Equipment Configuration" alarms/conditions | ||||
Multiple Generics |
DATAFLT |
X |
Procedure 5-44: Clear "Generic/Database/Equipment Configuration" alarms/conditions | ||||
Multiple Main Shelf TIDs |
DATAFLT |
X |
|||||
Muxponder CP failed |
FACTERM |
X |
X5 |
X |
X |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
neighbor SYSCTL CP unavailable (nbr tid = TID) |
CONTR |
X |
X |
X |
X |
X |
Procedure 5-100: Clear "neighbor SYSCTL CP unavailable (nbr tid = TID)" alarm |
Node ID Mismatch |
NID-CONFL |
X |
X |
X |
X |
X |
|
NP audit failed |
NPAUDT |
X |
X5 |
X |
X6 |
X |
|
NSAP count in L1 overflowed |
BUFROVLD |
X |
X |
X |
X |
X |
|
NSAP count in L1 threshold crossed |
BUFROVLD |
X |
X |
X |
X |
X |
Procedure 5-103: Clear "NSAP count in L1 threshold crossed" alarm |
NTP server(s) unreachable |
EOC |
X |
Procedure 5-104: Clear "NTP server(s) unreachable" condition | ||||
NUT Inconsistent XC Granularity |
NUTINXCGRN |
X |
X |
X |
X |
X |
Procedure 5-105: Clear "NUT Inconsistent XC Granularity" alarm |
NVM failed |
WKGMEM |
X7 |
X |
X |
X |
||
NVM removed or NVM failed |
WKGMEM |
X7 |
X |
X |
X |
||
NVM write disabled |
WKGMEM |
X2 |
No action is necessary. | ||||
OCN facility loopback |
LPBKNETWORK |
X2 |
|||||
OCN terminal loopback |
LPBKNETWORK |
X2 |
|||||
OLIU CP failed |
FACTERM |
X |
X5 |
X |
X6 |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
OMD CP failed |
FACTERM |
X |
X5 |
X |
X |
X | |
Path Integrity Failure |
PAINTGRT |
X |
X |
X |
X |
X |
|
Pluggable Transmission Module insufficient maximum rate |
FACTERM |
X |
X5 |
X |
X6 |
X |
Procedure 5-109: Clear "Pluggable Transmission Module insufficient maximum rate" alarm |
Pluggable Transmission Module maintenance IP |
MAN |
X2 |
Procedure 5-110: Clear "Pluggable Transmission Module maintenance IP" condition | ||||
Pluggable Transmission Module removed |
FACTERM |
X |
X5 |
X |
X6 |
X |
Procedure 5-111: Clear "Pluggable Transmission Module removed" alarm |
Port administratively disabled |
MAN |
X2 |
Procedure 5-113: Clear "Port administratively disabled" condition | ||||
Protection CP Input fault |
FACTERM |
X |
X |
X |
X |
X |
Procedure 5-116: Clear "PROTN Port Failure/Protection CP Input fault" alarms |
Protection switching byte failure |
APSB |
X |
X |
X |
X |
X |
Procedure 5-114: Clear "Protection switching byte failure" alarm |
Protection switching channel match failure |
APSCM |
X |
X |
X |
X |
X |
Procedure 5-115: Clear "Protection switching channel match failure" alarm |
PROTN DS3 Port Failure |
PROTNA |
X |
X |
X |
X |
X |
Procedure 5-116: Clear "PROTN Port Failure/Protection CP Input fault" alarms |
PROTN EC1 Port Failure |
PROTNA |
X |
X |
X |
X |
X | |
Receive buffer overflow |
BUFROVLD |
X2 |
|||||
Remote client signal failed |
GFP_RCF |
X |
X5 |
X |
X6 |
X |
|
remote install/copy program IP |
EOC |
X |
No action is necessary. | ||||
Ring Circuit Alarm Suppressed |
CKTAUDUD |
X2 |
Procedure 5-119: Clear "Ring Circuit Alarm Suppressed" condition | ||||
Ring Ckt Validation Suspended |
CKTAUDSNP |
X |
X |
X |
X |
X |
Procedure 5-120: Clear "Ring Ckt Validation Suspended" alarm |
Ring Comm Failure |
RNG-DSCVY |
X |
X |
X |
X |
X |
|
Ring Discovery In Progress |
RNG-DSCVY |
X2 |
No action is necessary. | ||||
Ring Incomplete |
RNG-INC |
X |
X |
X |
X |
X |
|
Ring Prot Switching Suspended |
OVRDSW |
X |
X |
X |
X |
X |
Procedure 5-123: Clear "Ring Prot Switching Suspended" alarm |
ring upgrade mode |
RINGUPGRADE |
X2 |
|||||
RPR Miscabling |
MISCBL |
X2 |
|||||
RPR Topology Exceeded Max Stations |
TOPO-MAX |
X2 |
Procedure 5-126: Clear "RPR Topology Exceeded Max Stations" condition | ||||
RPR Topology Inconsistency |
TOPO-INCS |
X2 |
Procedure 5-127: Clear "RPR Topology Inconsistency" condition | ||||
RPR Topology Map Entry Invalid |
TOPO-INV |
X2 |
Procedure 5-128: Clear "RPR Topology Map Entry Invalid" condition | ||||
RPR Topology Unstable |
TOPO-UNST |
X2 |
|||||
section DCC channel failed |
EOC |
X |
X |
X |
X |
X |
|
Segment audit failed LAN in |
SEGAUDTIN |
X |
X |
X |
X |
X |
|
Segment audit failed LAN out |
SEGAUDTOUT |
X |
X |
X |
X |
X | |
Segment audit failed VCG in |
SEGAUDTIN |
X |
X |
X |
X |
X | |
Segment audit failed VCG out |
SEGAUDTOUT |
X |
X |
X |
X |
X | |
Squelch Map Inconsistent |
SQMAP-INCST |
X |
X |
X |
X |
X |
|
Squelch Data Unavailable |
SQDATA-UNAV |
X |
X |
X |
X |
X |
|
STP autolock port disable |
AUTOLOCK |
X |
X |
X |
X |
X |
|
Subshelf Boot Failed |
DATAFLT |
X |
|||||
Subshelf Communication Failed |
REMLINK |
X |
X |
X |
X |
X |
Procedure 5-134: Clear "Subshelf Communication Failed” alarm |
Subshelf Configuration Mismatch |
DATAFLT |
X |
|||||
Subshelf initialization IP |
EOC |
X |
X |
X |
X |
X |
No action is necessary. |
SYSCTL CP failed |
CONTR |
X |
X |
X |
X |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
SYS dorm area corrupted |
EOC |
X |
|||||
SYS generic corrupted |
EOC |
X |
X |
X |
X |
||
SWITCH CP failed |
FACTERM |
X |
X |
X |
X |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
Temporarily NUT Provisioned |
NUTTMPPRV |
X |
Procedure 5-138: Clear "Temporarily NUT Provisioned" condition | ||||
Test access IP |
TSTACC |
X2 |
|||||
Test access IP:tsn |
TSTACC |
X2 | |||||
time of day not provisioned |
CONTR |
X |
Procedure 5-140: Clear "time of day not provisioned" condition | ||||
TMUX CP failed |
FACTERM |
X |
X5 |
X |
X6 |
X |
Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms |
Traffic Squelched |
RNG-SQUELCH |
X |
|||||
unexpected circuit pack type |
FACTERM |
X2 |
No action is necessary. | ||||
unexpected CP type |
FACTERM |
X |
X5 |
X |
X6 |
X |
|
unexpected or failed Pluggable Transmission Module |
FACTERM |
X |
X5 |
X |
X6 |
X |
Procedure 5-143: Clear "unexpected or failed Pluggable Transmission Module" alarm |
Unknown Ring Type |
RNG-URT |
X2 |
|||||
unrecoverable hardware failure during download, replace CP |
FACTERM |
X |
Procedure 5-145: Clear "unrecoverable hardware failure during download, replace CP" alarm | ||||
VCG Failure of LCAS Protocol (Sink) |
VCGFOPR |
X |
X |
X |
X5,6 |
X |
Procedure 5-146: Clear "VCG Failure of LCAS Protocol" alarms |
VCG Failure of LCAS Protocol (Source) |
VCGFOPT |
X |
X |
X |
X5,6 |
X |
Procedure 5-146: Clear "VCG Failure of LCAS Protocol" alarms |
VCG Loss of Partial Capacity |
VCGLOPC |
X |
X |
X |
X5,6 |
X |
|
version mismatch |
FACTERM |
X |
X |
X |
X |
X |
|
waiting for download |
FACTERM |
X2 |
No action is necessary. |
SC (Standing Conditions) are either events (usually user initiated such as switch requests) or alarms that are provisioned NA (Not Alarmed).
Standing conditions that are reported with an ABN condition in the alarm list. They are also identified on the SYSCTL faceplate by a lighted ABN LED.
STSN represent STS-1, STS-3c, STS-12c, STS-48c, and STS-192c.
The alarms/conditions with an X in the ASAP column indicate that the alarm/condition is part of an ASAP. The alarm/condition may be either an alarm or an event and is provisionable to CR, MJ, MN, NA (Not Alarmed), or NR (Not Reported). View the ASAP assigned to the specific entities to determine which alarm levels apply.
Service affecting default value.
Non-service affecting default value.
This alarm is provisionable to CR, MJ, or MN. This ASAP does not support NA (Not Alarmed) or NR (Not Reported).
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |