Alarm list with severity levels

Overview

This section provides the reported alarm list with severity levels.

Alarm list

Important!

The severity level for certain alarms is provisionable. In the table below, a bold X identifies the default severity level for alarm messages that have provisionable severity levels. If there are multiple severity levels listed, yet there is no bold X, the severity level for that alarm or condition is determined by equipment provisioning.

Table 2-1: Alcatel-Lucent 1665 DMXtend, Release 9.1 reported alarm list

Name

Probable Cause

ASAP4

Severity Level

Go to

CR

MJ

MN

SC1

−48V power/fuse FA failed

PWR

X

X

X

X

X

Procedure 5-2: Clear "−48V power/fuse FA or FB failed" alarm

−48V power/fuse FB failed

PWR

X

X

X

X

X

ABN condition

MAN

X2

Locate the corresponding Not Alarmed (SC) in the alarm list and proceed to the appropriate procedure to release/clear the condition.

ACO active

INHAUDB

X

No action is necessary.

AGNE communication failure

PRCDRERR

X

X

X

X

X

Procedure 5-3: Clear "AGNE communication failure" alarm

AUTO link shutdown

ALS

X

X

X

X

X2

Procedure 5-5: Clear "AUTO link shutdown" alarm

automatic lock

WKSWPR-1 WKSWPR-2

X2

Procedure 5-6: Clear "automatic lock" condition

Automatic protection switch mode mismatch

APSMM

X

X

X

X

X

Procedure 5-7: Clear "Automatic protection switch mode mismatch" alarm

copy program IP

EOC

X

No action is necessary.

CP contributing to a pack failure

CTNEQPT

X

X

X

X

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

CP initialization IP

FACTERM

X

No action is necessary.

CP not allowed - crs

FACTERM

X

X

X

X6

X

Procedure 5-10: Clear "CP not allowed - crs" alarm

CP not allowed - eqpt

FACTERM

X

X

X

X6

X

Procedure 5-11: Clear "CP not allowed - eqpt" alarm

CP removed or CP failure

FACTERM

X

X5

X

X6

X

Procedure 5-12: Clear "CP removed or CP failure" alarm

CP software upgrade required

FACTERM

X

Procedure 5-13: Clear "CP software upgrade required" condition

CPY-MEM backup IP

EOC

X

No action is necessary.

CPY-MEM download IP

EOC

X

CPY-MEM restore IP

EOC

X

DATA CP failed

FACTERM

X

X

X

X

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

DATA terminal loopback

LPBKNETWORK

X2

Procedure 5-14: Clear "DATA terminal loopback" condition

dormant/exec code mismatch

EOC

X

Procedure 5-15: Clear "dormant/exec code mismatch" condition

DS1 CP failed

FACTERM

X

X5

X

X6

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

DS1E1 CP failed

FACTERM

X

X5

X

X6

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

DS1 loopback (to DSX)

LPBKNETWORK

X2

Procedure 5-16: Clear "DS1 loopback (to DSX)" condition

DS1 loopback (to Fiber)

LPBKNETWORK

X2

Procedure 5-17: Clear "DS1 loopback (to Fiber)" condition

DS1 trmsn test IP

LPBKNETWORK

X2

No action is necessary.

DS3 loopback (to DSX)

LPBKNETWORK

X2

Procedure 5-18: Clear "DS3 loopback (to DSX)" condition

DS3 loopback (to Fiber)

LPBKNETWORK

X2

Procedure 5-19: Clear "DS3 loopback (to Fiber)" condition

DS3 trmsn test IP

LPBKNETWORK

X2

No action is necessary.

DS3EC1 CP failed

FACTERM

X

X5

X

X6

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

E1 loopback (to DSX)

LPBKNETWORK

X2

Procedure 5-20: Clear "E1 loopback (to DSX)" condition

E1 loopback (to Fiber)

LPBKNETWORK

X2

Procedure 5-21: Clear "E1 loopback (to Fiber)" condition

E1 trmsn test IP

LPBKNETWORK

X2

No action is necessary.

EC1 loopback (to DSX)

LPBKNETWORK

X2

Procedure 5-22: Clear "EC1 loopback (to DSX)" condition

EC1 loopback (to Fiber)

LPBKNETWORK

X2

Procedure 5-23: Clear "EC1 loopback (to Fiber)" condition

ECV - excessive code violation

ECV

X

X

X

X

X

Procedure 5-24: Clear "ECV - excessive code violation" alarm

ENET facility loopback

LPBKNETWORK

X2

Procedure 5-25: Clear "ENET loopback" conditions

ENET terminal loopback

LPBKNETWORK

X2

ENNI signaling communication failure with peer

SIGPEER

X

X

X

X

X

Procedure 5-26: Clear "ENNI signaling communication failure with peer" alarm

environmentn

MISC

X

X

X

X

Procedure 5-27: Clear "environmentn" alarm

Equipment configuration no longer supported

DATAFLT

X

Procedure 5-36: Clear "Generic/Database/Equipment Configuration" alarms/conditions

ERP - Multiple RPL Owners

ERP-MO

X

X

X

X

X

Procedure 5-28: Clear "ERP - Multiple RPL Owners" alarm

ERP - PDU Watchdog Timeout

ERP-WD

X

X

X

X

X

Procedure 5-29: Clear "ERP - PDU Watchdog Timeout" alarm

Exceeded MTU size drop

EMSD

X

X

X

X

X

Procedure 5-30: Clear "Exceeded MTU size drop" alarm

excessive holdover

LHI

X

X

X

X

X

Procedure 5-37: Clear "holdover" conditions/alarms

Excessive Reserved Rate on RPR

EXS-RSV

X2

Procedure 5-31: Clear "Excessive Reserved Rate on RPR" condition

fan shelf failed

EXT

X

X

X

X

Procedure 5-32: Clear "fan shelf failed" alarm

far end not LCAS

NOTLCAS

X

Procedure 5-33: Clear "far end not LCAS" condition

Far-end protection line failure

FEPRLF

X

X

X

X

X

Procedure 5-34: Clear "Far-end protection line failure" alarm

FE-LAN CP failed

FACTERM

X

X

X

X

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

forced switch

WKSWPR-1 WKSWPR-2

X2

Procedure 5-35: Clear "forced switch" condition

GE-LAN CP failed

FACTERM

X

X

X

X

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

generic validation IP

EOC

X

No action is necessary.

holdover mode active

HLDOVRSYNC

X

Procedure 5-37: Clear "holdover" conditions/alarms

illegal CP type

FACTERM

X5

X

X

X6

X

Procedure 5-38: Clear "illegal CP type" alarm

inc. DS1 sync. ref. AIS

SYNC

X

X

X

X

X

Procedure 5-40: Clear "inc. DS1/E1 sync. ref." alarms

SYNCOOS

X

X

X

X

X

inc. DS1 sync. ref. BER

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. DS1 sync. ref. EOOF

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. DS1 sync. ref. LOF

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. DS1 sync. ref. LOS

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. DS1 sync. ref. OOL

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. DS3 Cbit Mismatch

CBITMM

X

X

X

X

X

Procedure 5-43: Clear "inc. DS3 Cbit Mismatch" alarm

inc. E1 sync. ref. AIS

SYNC

X

X

X

X

X

Procedure 5-40: Clear "inc. DS1/E1 sync. ref." alarms

SYNCOOS

X

X

X

X

X

inc. E1 sync. ref. BER

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. E1 sync. ref. CRC-4 MFA mismatch

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. E1 sync. ref. LOF

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. E1 sync. ref. LOS

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. E1 sync. ref. OOL

SYNC

X

X

X

X

X

SYNCOOS

X

X

X

X

X

inc. (from DSX) DS1 AIS

AIS

X

X

X

X

X

Procedure 5-41: Clear "inc. (from DSX) DS1" alarms

inc. (from DSX) DS1 LOF

LOF

X

X

X

X

X

inc. (from DSX) DS1 LOS

LOS

X

X

X

X

X

inc. (from DSX) DS1 RAI

RAI

X

X

X

X

X

Procedure 5-44: Clear "inc. (from DSX) DSn RAI" alarm

inc. (from DSX) DS1 sig. failed

T-BERL

X

X

X

X

X

Procedure 5-41: Clear "inc. (from DSX) DS1" alarms

inc. (from DSX) DS3 AIS

AIS

X

X

X

X

X

Procedure 5-42: Clear "inc. (from DSX) DS3" alarms

inc. (from DSX) DS3 IDLE

IDLE

X

X

X

X

X

inc. (from DSX) DS3 LOF

LOF

X

X

X

X

X

inc. (from DSX) DS3 LOS

LOS

X

X

X

X

X

inc. (from DSX) DS3 RAI

RAI

X

X

X

X

X

Procedure 5-44: Clear "inc. (from DSX) DSn RAI" alarm

inc. (from DSX) DS3 sig. failed

T-BERL

X

X

X

X

X

Procedure 5-42: Clear "inc. (from DSX) DS3" alarms

inc. (from fiber) DS1 AIS

AIS-EGR

X

X

X

X

X

Procedure 5-45: Clear "inc. (from fiber) DSn" alarms

inc. (from fiber) DS1 LOF

LOF-EGR

X

X

X

X

X

inc. (from fiber) DS1 RAI

RAI-EGR

X

X

X

X

X

Procedure 5-46: Clear "inc. (from fiber) DSn RAI" alarms

inc. (from fiber) DS3 AIS

AIS-EGR

X

X

X

X

X

Procedure 5-45: Clear "inc. (from fiber) DSn" alarms

inc. (from fiber) DS3 LOF

LOF-EGR

X

X

X

X

X

inc. (from fiber) DS3 RAI

RAI-EGR

X

X

X

X

X

Procedure 5-46: Clear "inc. (from fiber) DSn RAI" alarms

inc. (from DSX) E1 AIS

AIS

X

X

X

X

X

Procedure 5-47: Clear "inc. (from DSX) E1" alarms

inc. (from DSX) E1 LOF

LOF

X

X

X

X

X

inc. (from DSX) E1 LOS

LOS

X

X

X

X

X

inc. (from DSX) E1 sig. failed

T-BERL

X

X

X

X

X

inc. EC1 line AIS

AIS

X

X

X

X

X

Procedure 5-48: Clear "inc. EC1" alarms

inc. EC1 LOF

LOF

X

X

X

X

X

inc. EC1 LOS

LOS

X

X

X

X

X

inc. EC1 RFI-L

FERF

X

X

X

X

X

inc. EC1 section trace identifier mismatch

TIM-S

X

X

X5

X6

X

Procedure 5-64: Clear "inc. section trace identifier mismatch" alarms

inc. EC1 section trace identifier mismatch, diagnostic

TIM-S-D

X

X

X

X

X

inc. EC1 sig. degrade (BER)

T-BERL

X

X

X

X

X

Procedure 5-48: Clear "inc. EC1" alarms

inc. EC1 sig. failed (BER)

T-BERL

X

X

X

X

X

inc. FE-LAN ANM

ANM

X

X

X

X

X

Procedure 5-49: Clear "inc. FE-LAN ANM" alarm

inc. FE-LAN FEFI

FERF

X

X

X

X

X

Procedure 5-50: Clear "inc. FE-LAN FEFI" alarm

inc. FE-LAN LOS

LOS

X

X

X

X

X

Procedure 5-51: Clear "inc. FE-LAN LOS" alarm

inc. GE-LAN ANM

ANM

X

X5

X

X6

X

Procedure 5-52: Clear "inc. GE-LAN ANM" alarm

inc. GE-LAN LOS

LOS

X

X5

X

X6

X

Procedure 5-53: Clear "inc. GE-LAN LOS" alarm

inc. LAG Partial Link Loss

PLL

X

X

X

X

X

Procedure 5-55: Clear "inc. LAG" alarms

inc. LAG PLCF

PLCF

X

X

X

X

X

inc. LAG Total Link Loss

TLL

X

X

X

X

X

inc. line sync. ref. OOL

SYNC

X

X

X

X

X

Procedure 5-54: Clear "inc. line sync. ref. OOL" alarm

SYNCOOS

X

X

X

X

X

inc. LOS

LOS

X

X5

X

X6

X

Procedure 5-56: Clear "inc. LOS" alarm

inc. Loss of Synch

LSYNC

X

X5

X

X6

X

Procedure 5-57: Clear "inc. Loss of Synch" alarm

inc. MUX OCH LOS-P

MUX-LOS-P

X

X

X

X

X

Procedure 5-58: Clear "inc. MUX OCH LOS-P" alarm

inc. OCN line AIS

AIS

X

X5

X

X

X6

Procedure 5-59: Clear "inc. OCN" alarms

inc. OCN LOF

LOF

X

X5

X

X6

X

inc. OCN LOS

LOS

X

X5

X

X6

X

inc. OCN RFI-L

FERF

X

X

X

X

X

Procedure 5-60: Clear "inc. OCN RFI-L" alarm

inc. OCN section trace identifier mismatch

TIM-S

X

X

X5

X6

X

Procedure 5-64: Clear "inc. section trace identifier mismatch" alarms

inc. OCN section trace identifier mismatch, diagnostic

TIM-S-D

X

X

X

X

X

inc. OCN sig. degrade (BER)

T-BERL

X

X5

X

X6

X

Procedure 5-59: Clear "inc. OCN" alarms

inc. OCN sig. failed (BER)

T-BERL

X

X5

X

X6

X

inc. ODU2 BDI

BDI

X

X

X

X

X6

Procedure 5-8: Clear "inc. BDI" alarms

inc. ODU2 DEG

DEG

X

X5

X

X6

X

Procedure 5-62: Clear "inc. ODU2/OTU2" alarms

inc. ODU2 LCK

LCK

X

X5

X

X6

X

Procedure 5-61: Clear "inc. ODU2 LCK/OCI" alarms

inc. ODU2 OCI

OCI

X

X5

X

X6

X

inc. ODU2 SSF

SSF

X

X5

X

X6

X

Procedure 5-62: Clear "inc. ODU2/OTU2" alarms

inc. OTS LOS-P

LOS-P

X

X5

X

X6

X

Procedure 5-63: Clear "inc. OTS LOS-P" alarm

inc. OTU2 BDI

BDI

X

X

X

X

X6

Procedure 5-8: Clear "inc. BDI" alarms

inc. OTU2 DEG

DEG

X

X5

X

X6

X

Procedure 5-62: Clear "inc. ODU2/OTU2" alarms

inc. OTU2 LOF

LOF

X

X5

X

X6

X

inc. OTU2 LOM

LOM

X

X5

X

X6

X

inc. OTU2 LOS-P

LOS-P

X

X5

X

X6

X

inc. OTU2 SSF

SSF

X

X5

X

X6

X

inc. STS LOP

LOP

X

X5

X

X6

X

Procedure 5-48: Clear "inc. EC1" alarms

inc. STSN3 AIS

AIS

X

X5

X

X6

X

Procedure 5-65: Clear "inc. STSN" conditions/alarms

inc. STSN LOP

LOP

X

X5

X

X6

X

inc. STSN RFI-P

YEL

X

X

X

X

X

inc. STSN sig. degrade (BER)

T-BERP

X

X5

X

X6

X

inc. STSN sig. failed (BER)

T-BERP

X

X5

X

X6

X

inc. STSN unequipped

SLMF

X

X5

X

X6

X

inc. VCG failed

LOS

X

X5

X

X6

X

Procedure 5-66: Clear "inc. VCG failed" alarm

inc. VCG LFD

MISC

X

Procedure 5-67: Clear "inc. VCG LFD" condition

inc. VCG LOA

MISC

X

Procedure 5-68: Clear "inc. VCG LOA" condition

inc. VC TU-AIS

AIS

X

X

X

X

X

Procedure 5-69: Clear "inc. VC" conditions/alarms

inc. VC TU-LOP

LOP

X

X

X

X

X

inc. VC LP-RFI

YEL

X

X

X

X

X

inc. VC unequipped

SLMF

X

X

X

X

X

inc. VT AIS

AIS

X

X

X5

X6

X

Procedure 5-70: Clear "inc. VT" conditions/alarms

inc. VT LOP

LOP

X

X

X5

X6

X

inc. VT RFI-V

YEL

X

X

X

X

X

inc. VT sig. degrade (BER)

T-BERP

X

X

X5

X6

X

inc. VT unequipped

SLMF

X

X

X5

X6

X

incoming CRC-4 MFA mismatch

CRCMM

X

X

X

X

X

Procedure 5-71: Clear "incoming CRC-4 MFA mismatch" condition

Inconsistent crs map

CONTR

X

Procedure 5-72: Clear "Inconsistent crs map" alarm

inconsistent DCC values

OSILINKERR

X

X

X

X

X

Procedure 5-73: Clear "inconsistent DCC values" alarm

inhibit switch

INHSWPR

WKSWPR-1

WKSWPR-2

X

X

X

X

X2

Procedure 5-74: Clear "inhibit switch" condition

install failed

FACTERM

X2

Procedure 5-75: Clear "install failed" condition

install program IP

EOC

SWFTDWN

X

No action is necessary.

Invalid Database

DATAFLT

X

Procedure 5-36: Clear "Generic/Database/Equipment Configuration" alarms/conditions

line DCC channel failed

EOC-L

X

X

X

X

X

Procedure 5-76: Clear "line DCC channel failed" alarm

lockout of protection

INHSWPR

X2

Procedure 5-77: Clear "lockout of protection" condition

Maintenance Mode

DATAFLT

X2

Procedure 5-36: Clear "Generic/Database/Equipment Configuration" alarms/conditions

manual reference switch

WKSWPR-1 WKSWPR-2

X2

Procedure 5-78: Clear "manual reference switch" condition

manual switch

WKSWPR-1 WKSWPR-2

MSR

X2

Procedure 5-79: Clear "manual switch" condition

manual sync. mode switch

HLDOVRSYNC

X2

Procedure 5-80: Clear "manual sync. mode switch" condition

Member Not Collecting/ Distributing

MNCD

X

X

X

X

X

Procedure 5-81: Clear "Member Not Collecting/Distributing" alarm

Member Signal Unacceptable - LCAS

MSU-L

X

X

X

X5,6

X

Procedure 5-82: Clear "Member Signal Unacceptable - LCAS" alarm

Multiple Databases

DATAFLT

X

Procedure 5-36: Clear "Generic/Database/Equipment Configuration" alarms/conditions

Multiple Generics

DATAFLT

X

Procedure 5-36: Clear "Generic/Database/Equipment Configuration" alarms/conditions

Muxponder CP failed

FACTERM

X

X5

X

X

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

neighbor SYSCTL CP unavailable (nbr tid = TID)

CONTR

X

X

X

X

X

Procedure 5-83: Clear "neighbor SYSCTL CP unavailable (nbr tid = TID)" alarm

NSAP count in L1 overflowed

BUFROVLD

X

X

X

X

X

Procedure 5-84: Clear "NSAP count in L1 overflowed" alarm

NSAP count in L1 threshold crossed

BUFROVLD

X

X

X

X

X

Procedure 5-85: Clear "NSAP count in L1 threshold crossed" alarm

NTP server(s) unreachable

EOC

X

Procedure 5-86: Clear "NTP server(s) unreachable" condition

NVM failed

WKGMEM

X7

X

X

X

Procedure 5-87: Clear "NVM" alarms

NVM removed or NVM failed

WKGMEM

X7

X

X

X

Procedure 5-87: Clear "NVM" alarms

NVM write disabled

WKGMEM

X2

No action is necessary.

OCN facility loopback

LPBKNETWORK

X2

Procedure 5-88: Clear "OCN facility loopback" condition

OCN terminal loopback

LPBKNETWORK

X2

Procedure 5-89: Clear "OCN terminal loopback" condition

OLIU CP failed

FACTERM

X

X5

X

X6

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

OMD CP failed

FACTERM

X

X5

X

X

X

Pluggable Transmission Module insufficient maximum rate

FACTERM

X

X5

X

X6

X

Procedure 5-90: Clear "Pluggable Transmission Module insufficient maximum rate" alarm

Pluggable Transmission Module maintenance IP

MAN

X2

Procedure 5-91: Clear "Pluggable Transmission Module maintenance IP" condition

Pluggable Transmission Module removed

FACTERM

X

X5

X

X6

X

Procedure 5-92: Clear "Pluggable Transmission Module removed" alarm

Port administratively disabled

MAN

X2

Procedure 5-93: Clear "Port administratively disabled" condition

Protection CP Input fault

FACTERM

X

X

X

X

X

Procedure 5-96: Clear "PROTN Port Failure/Protection CP Input fault" alarms

Protection switching byte failure

APSB

X

X

X

X

X

Procedure 5-94: Clear "Protection switching byte failure" alarm

Protection switching channel match failure

APSCM

X

X

X

X

X

Procedure 5-95: Clear "Protection switching channel match failure" alarm

PROTN DS3 Port Failure

PROTNA

X

X

X

X

X

Procedure 5-96: Clear "PROTN Port Failure/Protection CP Input fault" alarms

PROTN EC1 Port Failure

PROTNA

X

X

X

X

X

Receive buffer overflow

BUFROVLD

X2

Procedure 5-97: Clear "Receive buffer overflow" condition

Remote client signal failed

GFP_RCF

X

X5

X

X6

X

Procedure 5-98: Clear "Remote client signal failed" alarm

remote install/copy program IP

EOC

X

No action is necessary.

ring upgrade mode

RINGUPGRADE

X2

Procedure 5-99: Clear "ring upgrade mode" condition

RPR Miscabling

MISCBL

X2

Procedure 5-100: Clear "RPR Miscabling" condition

RPR Topology Exceeded Max Stations

TOPO-MAX

X2

Procedure 5-101: Clear "RPR Topology Exceeded Max Stations" condition

RPR Topology Inconsistency

TOPO-INCS

X2

Procedure 5-102: Clear "RPR Topology Inconsistency" condition

RPR Topology Map Entry Invalid

TOPO-INV

X2

Procedure 5-103: Clear "RPR Topology Map Entry Invalid" condition

RPR Topology Unstable

TOPO-UNST

X2

Procedure 5-104: Clear "RPR Topology Unstable" condition

section DCC channel failed

EOC

X

X

X

X

X

Procedure 5-105: Clear "section DCC channel failed" alarm

Segment audit failed LAN in

SEGAUDTIN

X

X

X

X

X

Procedure 5-4: Clear "audit failed" alarms

Segment audit failed LAN out

SEGAUDTOUT

X

X

X

X

X

Segment audit failed VCG in

SEGAUDTIN

X

X

X

X

X

Segment audit failed VCG out

SEGAUDTOUT

X

X

X

X

X

STP autolock port disable

AUTOLOCK

X

X

X

X

X

Procedure 5-106: Clear "STP autolock port disable" alarm

SYSCTL CP failed

CONTR

X

X

X

X

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

SYS dorm area corrupted

EOC

X

Procedure 5-107: Clear "SYS dorm area corrupted" condition

SYS generic corrupted

EOC

X

X

X

X

Procedure 5-108: Clear "SYS generic corrupted" alarm

Test access IP

TSTACC

X2

Procedure 5-109: Clear "Test access IP" conditions

Test access IP:tsn

TSTACC

X2

time of day not provisioned

CONTR

X

Procedure 5-110: Clear "time of day not provisioned" condition

TMUX CP failed

FACTERM

X

X5

X

X6

X

Procedure 5-9: Clear "CP failed/CP contributing to a pack failure" alarms

unexpected circuit pack type

FACTERM

X2

No action is necessary.

unexpected CP type

FACTERM

X

X5

X

X6

X

Procedure 5-111: Clear "unexpected CP type" alarm

unexpected or failed Pluggable Transmission Module

FACTERM

X

X5

X

X6

X

Procedure 5-112: Clear "unexpected or failed Pluggable Transmission Module" alarm

unrecoverable hardware failure during download, replace CP

FACTERM

X

Procedure 5-113: Clear "unrecoverable hardware failure during download, replace CP" alarm

VCG Failure of LCAS Protocol (Sink)

VCGFOPR

X

X

X

X5,6

X

Procedure 5-114: Clear "VCG Failure of LCAS Protocol" alarms

VCG Failure of LCAS Protocol (Source)

VCGFOPT

X

X

X

X5,6

X

Procedure 5-114: Clear "VCG Failure of LCAS Protocol" alarms

VCG Loss of Partial Capacity

VCGLOPC

X

X

X

X5,6

X

Procedure 5-115: Clear "VCG Loss of Partial Capacity" alarm

version mismatch

FACTERM

X

X

X

X

X

Procedure 5-116: Clear "version mismatch" alarm

waiting for download

FACTERM

X2

No action is necessary.

Notes:
  1. SC (Standing Conditions) are either events (usually user initiated such as switch requests) or alarms that are provisioned NA (Not Alarmed).

  2. Standing conditions that are reported with an ABN condition in the alarm list. They are also identified on the SYSCTL faceplate by a lighted ABN LED.

  3. STSN represent STS-1, STS-3c, STS-12c, and STS-48c.

  4. The alarms/conditions with an X in the ASAP column indicate that the alarm/condition is part of an ASAP. The alarm/condition may be either an alarm or an event and is provisionable to CR, MJ, MN, NA (Not Alarmed), or NR (Not Reported). View the ASAP assigned to the specific entities to determine which alarm levels apply.

  5. Service affecting default value.

  6. Non-service affecting default value.

  7. This alarm is provisionable to CR, MJ, or MN. This ASAP does not support NA (Not Alarmed) or NR (Not Reported).

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.